summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorChris Metcalf <cmetcalf@tilera.com>2012-03-30 22:24:41 +0200
committerChris Metcalf <cmetcalf@tilera.com>2012-04-02 18:13:56 +0200
commitcdd8e16feba87a3fc2bb1885d36f895a2a3288bf (patch)
tree26569389231172fbf0baf00f71e06dae7bab2583
parentarch/tile: fix finv_buffer_remote() for tilegx (diff)
downloadlinux-cdd8e16feba87a3fc2bb1885d36f895a2a3288bf.tar.xz
linux-cdd8e16feba87a3fc2bb1885d36f895a2a3288bf.zip
arch/tile: return SIGBUS for addresses that are unaligned AND invalid
Previously we were returning SIGSEGV in this case. It seems cleaner to return SIGBUS since the hardware figures out alignment traps before TLB violations, so SIGBUS is the "more correct" signal. Signed-off-by: Chris Metcalf <cmetcalf@tilera.com>
-rw-r--r--arch/tile/kernel/single_step.c31
1 files changed, 19 insertions, 12 deletions
diff --git a/arch/tile/kernel/single_step.c b/arch/tile/kernel/single_step.c
index bc1eb586e24d..9efbc1391b3c 100644
--- a/arch/tile/kernel/single_step.c
+++ b/arch/tile/kernel/single_step.c
@@ -153,6 +153,25 @@ static tile_bundle_bits rewrite_load_store_unaligned(
if (((unsigned long)addr % size) == 0)
return bundle;
+ /*
+ * Return SIGBUS with the unaligned address, if requested.
+ * Note that we return SIGBUS even for completely invalid addresses
+ * as long as they are in fact unaligned; this matches what the
+ * tilepro hardware would be doing, if it could provide us with the
+ * actual bad address in an SPR, which it doesn't.
+ */
+ if (unaligned_fixup == 0) {
+ siginfo_t info = {
+ .si_signo = SIGBUS,
+ .si_code = BUS_ADRALN,
+ .si_addr = addr
+ };
+ trace_unhandled_signal("unaligned trap", regs,
+ (unsigned long)addr, SIGBUS);
+ force_sig_info(info.si_signo, &info, current);
+ return (tilepro_bundle_bits) 0;
+ }
+
#ifndef __LITTLE_ENDIAN
# error We assume little-endian representation with copy_xx_user size 2 here
#endif
@@ -192,18 +211,6 @@ static tile_bundle_bits rewrite_load_store_unaligned(
return (tile_bundle_bits) 0;
}
- if (unaligned_fixup == 0) {
- siginfo_t info = {
- .si_signo = SIGBUS,
- .si_code = BUS_ADRALN,
- .si_addr = addr
- };
- trace_unhandled_signal("unaligned trap", regs,
- (unsigned long)addr, SIGBUS);
- force_sig_info(info.si_signo, &info, current);
- return (tile_bundle_bits) 0;
- }
-
if (unaligned_printk || unaligned_fixup_count == 0) {
pr_info("Process %d/%s: PC %#lx: Fixup of"
" unaligned %s at %#lx.\n",