dcdbas.txt: standardize document format
Each text file under Documentation follows a different format. Some doesn't even have titles! Change its representation to follow the adopted standard, using ReST markups for it to be parseable by Sphinx: - Mark titles; - Mark literal blocks; - Mark table. Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com> Signed-off-by: Jonathan Corbet <corbet@lwn.net>
-rw-r--r--Documentation/dcdbas.txt24
1 files changed, 16 insertions, 8 deletions
diff --git a/Documentation/dcdbas.txt b/Documentation/dcdbas.txt
index e1c52e2dc361..309cc57a7c1c 100644
--- a/Documentation/dcdbas.txt
+++ b/Documentation/dcdbas.txt
@@ -1,4 +1,9 @@
+===================================
+Dell Systems Management Base Driver
+===================================
+
Overview
+========
The Dell Systems Management Base Driver provides a sysfs interface for
systems management software such as Dell OpenManage to perform system
@@ -17,6 +22,7 @@ more information about the libsmbios project.
System Management Interrupt
+===========================
On some Dell systems, systems management software must access certain
management information via a system management interrupt (SMI). The SMI data
@@ -24,12 +30,12 @@ buffer must reside in 32-bit address space, and the physical address of the
buffer is required for the SMI. The driver maintains the memory required for
the SMI and provides a way for the application to generate the SMI.
The driver creates the following sysfs entries for systems management
-software to perform these system management interrupts:
+software to perform these system management interrupts::
-/sys/devices/platform/dcdbas/smi_data
-/sys/devices/platform/dcdbas/smi_data_buf_phys_addr
-/sys/devices/platform/dcdbas/smi_data_buf_size
-/sys/devices/platform/dcdbas/smi_request
+ /sys/devices/platform/dcdbas/smi_data
+ /sys/devices/platform/dcdbas/smi_data_buf_phys_addr
+ /sys/devices/platform/dcdbas/smi_data_buf_size
+ /sys/devices/platform/dcdbas/smi_request
Systems management software must perform the following steps to execute
a SMI using this driver:
@@ -43,6 +49,7 @@ a SMI using this driver:
Host Control Action
+===================
Dell OpenManage supports a host control feature that allows the administrator
to perform a power cycle or power off of the system after the OS has finished
@@ -69,12 +76,14 @@ power off host control action using this driver:
Host Control SMI Type
+=====================
The following table shows the value to write to host_control_smi_type to
perform a power cycle or power off host control action:
+=================== =====================
PowerEdge System Host Control SMI Type
----------------- ---------------------
+=================== =====================
300 HC_SMITYPE_TYPE1
1300 HC_SMITYPE_TYPE1
1400 HC_SMITYPE_TYPE2
@@ -87,5 +96,4 @@ PowerEdge System Host Control SMI Type
1655MC HC_SMITYPE_TYPE2
700 HC_SMITYPE_TYPE3
750 HC_SMITYPE_TYPE3
-
-
+=================== =====================