diff options
author | Kapileshwar Singh <kapileshwar.singh@arm.com> | 2015-03-16 13:00:50 +0100 |
---|---|---|
committer | Eduardo Valentin <edubezval@gmail.com> | 2015-05-05 06:27:54 +0200 |
commit | 54b92aae834ce8d02d6092f8ae5eb1fe0d607f1e (patch) | |
tree | a4080732551232952a85bca9731c8cfed6e2b196 | |
parent | thermal: export thermal_zone_parameters to sysfs (diff) | |
download | linux-54b92aae834ce8d02d6092f8ae5eb1fe0d607f1e.tar.xz linux-54b92aae834ce8d02d6092f8ae5eb1fe0d607f1e.zip |
thermal: cpu_cooling: Remove cpu_dev update on policy CPU update
It was initially understood that an update to the cpu_device
(cached in cpufreq_cooling_device) was required to ascertain the
correct operating point of the device on a cpufreq policy->cpu update
or creation or deletion of a cpufreq policy.
(e.g. when the existing policy CPU goes offline).
This update is not required and it is possible to ascertain the OPPs
from the leading CPU in a cpufreq domain even if the CPU is hotplugged out.
Fixes: e0128d8ab423 ("thermal: cpu_cooling: implement the power cooling device API")
Acked-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Kapileshwar Singh <kapileshwar.singh@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
-rw-r--r-- | drivers/thermal/cpu_cooling.c | 40 |
1 files changed, 0 insertions, 40 deletions
diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c index 3a01dfd5b29c..beffa556488a 100644 --- a/drivers/thermal/cpu_cooling.c +++ b/drivers/thermal/cpu_cooling.c @@ -199,39 +199,6 @@ unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq) } EXPORT_SYMBOL_GPL(cpufreq_cooling_get_level); -static void update_cpu_device(int cpu) -{ - struct cpufreq_cooling_device *cpufreq_dev; - - mutex_lock(&cooling_cpufreq_lock); - list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) { - if (cpumask_test_cpu(cpu, &cpufreq_dev->allowed_cpus)) { - cpufreq_dev->cpu_dev = get_cpu_device(cpu); - if (!cpufreq_dev->cpu_dev) { - dev_warn(&cpufreq_dev->cool_dev->device, - "No cpu device for new policy cpu %d\n", - cpu); - } - break; - } - } - mutex_unlock(&cooling_cpufreq_lock); -} - -static void remove_cpu_device(int cpu) -{ - struct cpufreq_cooling_device *cpufreq_dev; - - mutex_lock(&cooling_cpufreq_lock); - list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) { - if (cpumask_test_cpu(cpu, &cpufreq_dev->allowed_cpus)) { - cpufreq_dev->cpu_dev = NULL; - break; - } - } - mutex_unlock(&cooling_cpufreq_lock); -} - /** * cpufreq_thermal_notifier - notifier callback for cpufreq policy change. * @nb: struct notifier_block * with callback info. @@ -268,13 +235,6 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb, } mutex_unlock(&cooling_cpufreq_lock); break; - - case CPUFREQ_CREATE_POLICY: - update_cpu_device(policy->cpu); - break; - case CPUFREQ_REMOVE_POLICY: - remove_cpu_device(policy->cpu); - break; default: return NOTIFY_DONE; } |