thermal: cpu_cooling: use cpufreq_policy to register cooling device
The CPU cooling driver uses the cpufreq policy, to get clip_cpus, the frequency table, etc. Most of the callers of CPU cooling driver's registration routines have the cpufreq policy with them, but they only pass the policy->related_cpus cpumask. The __cpufreq_cooling_register() routine then gets the policy by itself and uses it. It would be much better if the callers can pass the policy instead directly. This also fixes a basic design flaw, where the policy can be freed while the CPU cooling driver is still active. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Reviewed-by: Lukasz Luba <lukasz.luba@arm.com> Tested-by: Lukasz Luba <lukasz.luba@arm.com> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
-rw-r--r--drivers/cpufreq/arm_big_little.c2
-rw-r--r--drivers/cpufreq/cpufreq-dt.c2
-rw-r--r--drivers/cpufreq/dbx500-cpufreq.c2
-rw-r--r--drivers/cpufreq/mt8173-cpufreq.c4
-rw-r--r--drivers/cpufreq/qoriq-cpufreq.c3
-rw-r--r--drivers/thermal/cpu_cooling.c61
-rw-r--r--drivers/thermal/imx_thermal.c22
-rw-r--r--drivers/thermal/ti-soc-thermal/ti-thermal-common.c22
-rw-r--r--include/linux/cpu_cooling.h26
9 files changed, 74 insertions, 70 deletions
diff --git a/drivers/cpufreq/arm_big_little.c b/drivers/cpufreq/arm_big_little.c
index 418042201e6d..ea6d62547b10 100644
--- a/drivers/cpufreq/arm_big_little.c
+++ b/drivers/cpufreq/arm_big_little.c
@@ -540,7 +540,7 @@ static void bL_cpufreq_ready(struct cpufreq_policy *policy)
&power_coefficient);
cdev[cur_cluster] = of_cpufreq_power_cooling_register(np,
- policy->related_cpus, power_coefficient, NULL);
+ policy, power_coefficient, NULL);
if (IS_ERR(cdev[cur_cluster])) {
dev_err(cpu_dev,
"running cpufreq without cooling device: %ld\n",
diff --git a/drivers/cpufreq/cpufreq-dt.c b/drivers/cpufreq/cpufreq-dt.c
index c943787d761e..fef3c2160691 100644
--- a/drivers/cpufreq/cpufreq-dt.c
+++ b/drivers/cpufreq/cpufreq-dt.c
@@ -326,7 +326,7 @@ static void cpufreq_ready(struct cpufreq_policy *policy)
&power_coefficient);
priv->cdev = of_cpufreq_power_cooling_register(np,
- policy->related_cpus, power_coefficient, NULL);
+ policy, power_coefficient, NULL);
if (IS_ERR(priv->cdev)) {
dev_err(priv->cpu_dev,
"running cpufreq without cooling device: %ld\n",
diff --git a/drivers/cpufreq/dbx500-cpufreq.c b/drivers/cpufreq/dbx500-cpufreq.c
index 3575b82210ba..4ee0431579c1 100644
--- a/drivers/cpufreq/dbx500-cpufreq.c
+++ b/drivers/cpufreq/dbx500-cpufreq.c
@@ -43,7 +43,7 @@ static int dbx500_cpufreq_exit(struct cpufreq_policy *policy)
static void dbx500_cpufreq_ready(struct cpufreq_policy *policy)
{
- cdev = cpufreq_cooling_register(policy->cpus);
+ cdev = cpufreq_cooling_register(policy);
if (IS_ERR(cdev))
pr_err("Failed to register cooling device %ld\n", PTR_ERR(cdev));
else
diff --git a/drivers/cpufreq/mt8173-cpufreq.c b/drivers/cpufreq/mt8173-cpufreq.c
index fd1886faf33a..f9f00fb4bc3a 100644
--- a/drivers/cpufreq/mt8173-cpufreq.c
+++ b/drivers/cpufreq/mt8173-cpufreq.c
@@ -320,9 +320,7 @@ static void mtk_cpufreq_ready(struct cpufreq_policy *policy)
of_property_read_u32(np, DYNAMIC_POWER, &capacitance);
info->cdev = of_cpufreq_power_cooling_register(np,
- policy->related_cpus,
- capacitance,
- NULL);
+ policy, capacitance, NULL);
if (IS_ERR(info->cdev)) {
dev_err(info->cpu_dev,
diff --git a/drivers/cpufreq/qoriq-cpufreq.c b/drivers/cpufreq/qoriq-cpufreq.c
index e2ea433a5f9c..4ada55b8856e 100644
--- a/drivers/cpufreq/qoriq-cpufreq.c
+++ b/drivers/cpufreq/qoriq-cpufreq.c
@@ -278,8 +278,7 @@ static void qoriq_cpufreq_ready(struct cpufreq_policy *policy)
struct device_node *np = of_get_cpu_node(policy->cpu, NULL);
if (of_find_property(np, "#cooling-cells", NULL)) {
- cpud->cdev = of_cpufreq_cooling_register(np,
- policy->related_cpus);
+ cpud->cdev = of_cpufreq_cooling_register(np, policy);
if (IS_ERR(cpud->cdev) && PTR_ERR(cpud->cdev) != -ENOSYS) {
pr_err("cpu%d is not running as cooling device: %ld\n",
diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
index 002b48dc6bea..58e58065b650 100644
--- a/drivers/thermal/cpu_cooling.c
+++ b/drivers/thermal/cpu_cooling.c
@@ -717,7 +717,7 @@ static unsigned int find_next_max(struct cpufreq_frequency_table *table,
/**
* __cpufreq_cooling_register - helper function to create cpufreq cooling device
* @np: a valid struct device_node to the cooling device device tree node
- * @clip_cpus: cpumask of cpus where the frequency constraints will happen.
+ * @policy: cpufreq policy
* Normally this should be same as cpufreq policy->related_cpus.
* @capacitance: dynamic power coefficient for these cpus
* @plat_static_func: function to calculate the static power consumed by these
@@ -733,45 +733,34 @@ static unsigned int find_next_max(struct cpufreq_frequency_table *table,
*/
static struct thermal_cooling_device *
__cpufreq_cooling_register(struct device_node *np,
- const struct cpumask *clip_cpus, u32 capacitance,
+ struct cpufreq_policy *policy, u32 capacitance,
get_static_t plat_static_func)
{
- struct cpufreq_policy *policy;
struct thermal_cooling_device *cdev;
struct cpufreq_cooling_device *cpufreq_cdev;
char dev_name[THERMAL_NAME_LENGTH];
struct cpufreq_frequency_table *pos, *table;
- cpumask_var_t temp_mask;
unsigned int freq, i, num_cpus;
int ret;
struct thermal_cooling_device_ops *cooling_ops;
bool first;
- if (!alloc_cpumask_var(&temp_mask, GFP_KERNEL))
- return ERR_PTR(-ENOMEM);
-
- cpumask_and(temp_mask, clip_cpus, cpu_online_mask);
- policy = cpufreq_cpu_get(cpumask_first(temp_mask));
- if (!policy) {
- pr_debug("%s: CPUFreq policy not found\n", __func__);
- cdev = ERR_PTR(-EPROBE_DEFER);
- goto free_cpumask;
+ if (IS_ERR_OR_NULL(policy)) {
+ pr_err("%s: cpufreq policy isn't valid: %p", __func__, policy);
+ return ERR_PTR(-EINVAL);
}
table = policy->freq_table;
if (!table) {
pr_debug("%s: CPUFreq table not found\n", __func__);
- cdev = ERR_PTR(-ENODEV);
- goto put_policy;
+ return ERR_PTR(-ENODEV);
}
cpufreq_cdev = kzalloc(sizeof(*cpufreq_cdev), GFP_KERNEL);
- if (!cpufreq_cdev) {
- cdev = ERR_PTR(-ENOMEM);
- goto put_policy;
- }
+ if (!cpufreq_cdev)
+ return ERR_PTR(-ENOMEM);
- num_cpus = cpumask_weight(clip_cpus);
+ num_cpus = cpumask_weight(policy->related_cpus);
cpufreq_cdev->time_in_idle = kcalloc(num_cpus,
sizeof(*cpufreq_cdev->time_in_idle),
GFP_KERNEL);
@@ -802,7 +791,7 @@ __cpufreq_cooling_register(struct device_node *np,
/* max_level is an index, not a counter */
cpufreq_cdev->max_level--;
- cpumask_copy(&cpufreq_cdev->allowed_cpus, clip_cpus);
+ cpumask_copy(&cpufreq_cdev->allowed_cpus, policy->related_cpus);
if (capacitance) {
cpufreq_cdev->plat_get_static_power = plat_static_func;
@@ -858,7 +847,7 @@ __cpufreq_cooling_register(struct device_node *np,
cpufreq_register_notifier(&thermal_cpufreq_notifier_block,
CPUFREQ_POLICY_NOTIFIER);
- goto put_policy;
+ return cdev;
remove_ida:
ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id);
@@ -872,16 +861,12 @@ free_time_in_idle:
kfree(cpufreq_cdev->time_in_idle);
free_cdev:
kfree(cpufreq_cdev);
-put_policy:
- cpufreq_cpu_put(policy);
-free_cpumask:
- free_cpumask_var(temp_mask);
return cdev;
}
/**
* cpufreq_cooling_register - function to create cpufreq cooling device.
- * @clip_cpus: cpumask of cpus where the frequency constraints will happen.
+ * @policy: cpufreq policy
*
* This interface function registers the cpufreq cooling device with the name
* "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
@@ -891,16 +876,16 @@ free_cpumask:
* on failure, it returns a corresponding ERR_PTR().
*/
struct thermal_cooling_device *
-cpufreq_cooling_register(const struct cpumask *clip_cpus)
+cpufreq_cooling_register(struct cpufreq_policy *policy)
{
- return __cpufreq_cooling_register(NULL, clip_cpus, 0, NULL);
+ return __cpufreq_cooling_register(NULL, policy, 0, NULL);
}
EXPORT_SYMBOL_GPL(cpufreq_cooling_register);
/**
* of_cpufreq_cooling_register - function to create cpufreq cooling device.
* @np: a valid struct device_node to the cooling device device tree node
- * @clip_cpus: cpumask of cpus where the frequency constraints will happen.
+ * @policy: cpufreq policy
*
* This interface function registers the cpufreq cooling device with the name
* "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
@@ -912,18 +897,18 @@ EXPORT_SYMBOL_GPL(cpufreq_cooling_register);
*/
struct thermal_cooling_device *
of_cpufreq_cooling_register(struct device_node *np,
- const struct cpumask *clip_cpus)
+ struct cpufreq_policy *policy)
{
if (!np)
return ERR_PTR(-EINVAL);
- return __cpufreq_cooling_register(np, clip_cpus, 0, NULL);
+ return __cpufreq_cooling_register(np, policy, 0, NULL);
}
EXPORT_SYMBOL_GPL(of_cpufreq_cooling_register);
/**
* cpufreq_power_cooling_register() - create cpufreq cooling device with power extensions
- * @clip_cpus: cpumask of cpus where the frequency constraints will happen
+ * @policy: cpufreq policy
* @capacitance: dynamic power coefficient for these cpus
* @plat_static_func: function to calculate the static power consumed by these
* cpus (optional)
@@ -943,10 +928,10 @@ EXPORT_SYMBOL_GPL(of_cpufreq_cooling_register);
* on failure, it returns a corresponding ERR_PTR().
*/
struct thermal_cooling_device *
-cpufreq_power_cooling_register(const struct cpumask *clip_cpus, u32 capacitance,
+cpufreq_power_cooling_register(struct cpufreq_policy *policy, u32 capacitance,
get_static_t plat_static_func)
{
- return __cpufreq_cooling_register(NULL, clip_cpus, capacitance,
+ return __cpufreq_cooling_register(NULL, policy, capacitance,
plat_static_func);
}
EXPORT_SYMBOL(cpufreq_power_cooling_register);
@@ -954,7 +939,7 @@ EXPORT_SYMBOL(cpufreq_power_cooling_register);
/**
* of_cpufreq_power_cooling_register() - create cpufreq cooling device with power extensions
* @np: a valid struct device_node to the cooling device device tree node
- * @clip_cpus: cpumask of cpus where the frequency constraints will happen
+ * @policy: cpufreq policy
* @capacitance: dynamic power coefficient for these cpus
* @plat_static_func: function to calculate the static power consumed by these
* cpus (optional)
@@ -976,14 +961,14 @@ EXPORT_SYMBOL(cpufreq_power_cooling_register);
*/
struct thermal_cooling_device *
of_cpufreq_power_cooling_register(struct device_node *np,
- const struct cpumask *clip_cpus,
+ struct cpufreq_policy *policy,
u32 capacitance,
get_static_t plat_static_func)
{
if (!np)
return ERR_PTR(-EINVAL);
- return __cpufreq_cooling_register(np, clip_cpus, capacitance,
+ return __cpufreq_cooling_register(np, policy, capacitance,
plat_static_func);
}
EXPORT_SYMBOL(of_cpufreq_power_cooling_register);
diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c
index fb648a45754e..f7ec39f46ee4 100644
--- a/drivers/thermal/imx_thermal.c
+++ b/drivers/thermal/imx_thermal.c
@@ -8,6 +8,7 @@
*/
#include <linux/clk.h>
+#include <linux/cpufreq.h>
#include <linux/cpu_cooling.h>
#include <linux/delay.h>
#include <linux/device.h>
@@ -88,6 +89,7 @@ static struct thermal_soc_data thermal_imx6sx_data = {
};
struct imx_thermal_data {
+ struct cpufreq_policy *policy;
struct thermal_zone_device *tz;
struct thermal_cooling_device *cdev;
enum thermal_device_mode mode;
@@ -525,13 +527,18 @@ static int imx_thermal_probe(struct platform_device *pdev)
regmap_write(map, MISC0 + REG_SET, MISC0_REFTOP_SELBIASOFF);
regmap_write(map, TEMPSENSE0 + REG_SET, TEMPSENSE0_POWER_DOWN);
- data->cdev = cpufreq_cooling_register(cpu_present_mask);
+ data->policy = cpufreq_cpu_get(0);
+ if (!data->policy) {
+ pr_debug("%s: CPUFreq policy not found\n", __func__);
+ return -EPROBE_DEFER;
+ }
+
+ data->cdev = cpufreq_cooling_register(data->policy);
if (IS_ERR(data->cdev)) {
ret = PTR_ERR(data->cdev);
- if (ret != -EPROBE_DEFER)
- dev_err(&pdev->dev,
- "failed to register cpufreq cooling device: %d\n",
- ret);
+ dev_err(&pdev->dev,
+ "failed to register cpufreq cooling device: %d\n", ret);
+ cpufreq_cpu_put(data->policy);
return ret;
}
@@ -542,6 +549,7 @@ static int imx_thermal_probe(struct platform_device *pdev)
dev_err(&pdev->dev,
"failed to get thermal clk: %d\n", ret);
cpufreq_cooling_unregister(data->cdev);
+ cpufreq_cpu_put(data->policy);
return ret;
}
@@ -556,6 +564,7 @@ static int imx_thermal_probe(struct platform_device *pdev)
if (ret) {
dev_err(&pdev->dev, "failed to enable thermal clk: %d\n", ret);
cpufreq_cooling_unregister(data->cdev);
+ cpufreq_cpu_put(data->policy);
return ret;
}
@@ -571,6 +580,7 @@ static int imx_thermal_probe(struct platform_device *pdev)
"failed to register thermal zone device %d\n", ret);
clk_disable_unprepare(data->thermal_clk);
cpufreq_cooling_unregister(data->cdev);
+ cpufreq_cpu_put(data->policy);
return ret;
}
@@ -599,6 +609,7 @@ static int imx_thermal_probe(struct platform_device *pdev)
clk_disable_unprepare(data->thermal_clk);
thermal_zone_device_unregister(data->tz);
cpufreq_cooling_unregister(data->cdev);
+ cpufreq_cpu_put(data->policy);
return ret;
}
@@ -620,6 +631,7 @@ static int imx_thermal_remove(struct platform_device *pdev)
thermal_zone_device_unregister(data->tz);
cpufreq_cooling_unregister(data->cdev);
+ cpufreq_cpu_put(data->policy);
return 0;
}
diff --git a/drivers/thermal/ti-soc-thermal/ti-thermal-common.c b/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
index 02790f69e26c..c211a8e4a210 100644
--- a/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
+++ b/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
@@ -28,6 +28,7 @@
#include <linux/kernel.h>
#include <linux/workqueue.h>
#include <linux/thermal.h>
+#include <linux/cpufreq.h>
#include <linux/cpumask.h>
#include <linux/cpu_cooling.h>
#include <linux/of.h>
@@ -37,6 +38,7 @@
/* common data structures */
struct ti_thermal_data {
+ struct cpufreq_policy *policy;
struct thermal_zone_device *ti_thermal;
struct thermal_zone_device *pcb_tz;
struct thermal_cooling_device *cool_dev;
@@ -247,15 +249,19 @@ int ti_thermal_register_cpu_cooling(struct ti_bandgap *bgp, int id)
if (!data)
return -EINVAL;
+ data->policy = cpufreq_cpu_get(0);
+ if (!data->policy) {
+ pr_debug("%s: CPUFreq policy not found\n", __func__);
+ return -EPROBE_DEFER;
+ }
+
/* Register cooling device */
- data->cool_dev = cpufreq_cooling_register(cpu_present_mask);
+ data->cool_dev = cpufreq_cooling_register(data->policy);
if (IS_ERR(data->cool_dev)) {
int ret = PTR_ERR(data->cool_dev);
-
- if (ret != -EPROBE_DEFER)
- dev_err(bgp->dev,
- "Failed to register cpu cooling device %d\n",
- ret);
+ dev_err(bgp->dev, "Failed to register cpu cooling device %d\n",
+ ret);
+ cpufreq_cpu_put(data->policy);
return ret;
}
@@ -270,8 +276,10 @@ int ti_thermal_unregister_cpu_cooling(struct ti_bandgap *bgp, int id)
data = ti_bandgap_get_sensor_data(bgp, id);
- if (data)
+ if (data) {
cpufreq_cooling_unregister(data->cool_dev);
+ cpufreq_cpu_put(data->policy);
+ }
return 0;
}
diff --git a/include/linux/cpu_cooling.h b/include/linux/cpu_cooling.h
index 96c5e4c2f9c8..d4292ebc5c8b 100644
--- a/include/linux/cpu_cooling.h
+++ b/include/linux/cpu_cooling.h
@@ -28,47 +28,49 @@
#include <linux/thermal.h>
#include <linux/cpumask.h>
+struct cpufreq_policy;
+
typedef int (*get_static_t)(cpumask_t *cpumask, int interval,
unsigned long voltage, u32 *power);
#ifdef CONFIG_CPU_THERMAL
/**
* cpufreq_cooling_register - function to create cpufreq cooling device.
- * @clip_cpus: cpumask of cpus where the frequency constraints will happen
+ * @policy: cpufreq policy.
*/
struct thermal_cooling_device *
-cpufreq_cooling_register(const struct cpumask *clip_cpus);
+cpufreq_cooling_register(struct cpufreq_policy *policy);
struct thermal_cooling_device *
-cpufreq_power_cooling_register(const struct cpumask *clip_cpus,
+cpufreq_power_cooling_register(struct cpufreq_policy *policy,
u32 capacitance, get_static_t plat_static_func);
/**
* of_cpufreq_cooling_register - create cpufreq cooling device based on DT.
* @np: a valid struct device_node to the cooling device device tree node.
- * @clip_cpus: cpumask of cpus where the frequency constraints will happen
+ * @policy: cpufreq policy.
*/
#ifdef CONFIG_THERMAL_OF
struct thermal_cooling_device *
of_cpufreq_cooling_register(struct device_node *np,
- const struct cpumask *clip_cpus);
+ struct cpufreq_policy *policy);
struct thermal_cooling_device *
of_cpufreq_power_cooling_register(struct device_node *np,
- const struct cpumask *clip_cpus,
+ struct cpufreq_policy *policy,
u32 capacitance,
get_static_t plat_static_func);
#else
static inline struct thermal_cooling_device *
of_cpufreq_cooling_register(struct device_node *np,
- const struct cpumask *clip_cpus)
+ struct cpufreq_policy *policy)
{
return ERR_PTR(-ENOSYS);
}
static inline struct thermal_cooling_device *
of_cpufreq_power_cooling_register(struct device_node *np,
- const struct cpumask *clip_cpus,
+ struct cpufreq_policy *policy,
u32 capacitance,
get_static_t plat_static_func)
{
@@ -84,12 +86,12 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev);
#else /* !CONFIG_CPU_THERMAL */
static inline struct thermal_cooling_device *
-cpufreq_cooling_register(const struct cpumask *clip_cpus)
+cpufreq_cooling_register(struct cpufreq_policy *policy)
{
return ERR_PTR(-ENOSYS);
}
static inline struct thermal_cooling_device *
-cpufreq_power_cooling_register(const struct cpumask *clip_cpus,
+cpufreq_power_cooling_register(struct cpufreq_policy *policy,
u32 capacitance, get_static_t plat_static_func)
{
return NULL;
@@ -97,14 +99,14 @@ cpufreq_power_cooling_register(const struct cpumask *clip_cpus,
static inline struct thermal_cooling_device *
of_cpufreq_cooling_register(struct device_node *np,
- const struct cpumask *clip_cpus)
+ struct cpufreq_policy *policy)
{
return ERR_PTR(-ENOSYS);
}
static inline struct thermal_cooling_device *
of_cpufreq_power_cooling_register(struct device_node *np,
- const struct cpumask *clip_cpus,
+ struct cpufreq_policy *policy,
u32 capacitance,
get_static_t plat_static_func)
{