summaryrefslogtreecommitdiffstats
path: root/Documentation/ABI/testing/sysfs-bus-iio-magnetometer-hmc5843
diff options
context:
space:
mode:
authorCristina Moraru <cristina.moraru09@gmail.com>2016-02-14 23:37:38 +0100
committerJonathan Cameron <jic23@kernel.org>2016-02-21 21:22:23 +0100
commit7b7a1c38d1d2e91cf68f3cfd4e0ac3cfa0936c4e (patch)
tree5c6028482c6a3b14f0aa9f455a38612c02bc8c5b /Documentation/ABI/testing/sysfs-bus-iio-magnetometer-hmc5843
parentiio: hmc5843: Add attributes for measurement config of bias current (diff)
downloadlinux-7b7a1c38d1d2e91cf68f3cfd4e0ac3cfa0936c4e.tar.xz
linux-7b7a1c38d1d2e91cf68f3cfd4e0ac3cfa0936c4e.zip
iio: hmc5843: Add ABI documentation file for hmc5843
Add ABI file documenting hmc5843 non-standard attributes meas_conf and meas_conf_available for bias current configuration. Signed-off-by: Cristina Moraru <cristina.moraru09@gmail.com> Cc: Daniel Baluta <daniel.baluta@intel.com> Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Diffstat (limited to 'Documentation/ABI/testing/sysfs-bus-iio-magnetometer-hmc5843')
-rw-r--r--Documentation/ABI/testing/sysfs-bus-iio-magnetometer-hmc584315
1 files changed, 15 insertions, 0 deletions
diff --git a/Documentation/ABI/testing/sysfs-bus-iio-magnetometer-hmc5843 b/Documentation/ABI/testing/sysfs-bus-iio-magnetometer-hmc5843
new file mode 100644
index 000000000000..6275e9f56e6c
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-bus-iio-magnetometer-hmc5843
@@ -0,0 +1,15 @@
+What: /sys/bus/iio/devices/iio:deviceX/meas_conf
+What: /sys/bus/iio/devices/iio:deviceX/meas_conf_available
+KernelVersion: 4.5
+Contact: linux-iio@vger.kernel.org
+Description:
+ Current configuration and available configurations
+ for the bias current.
+ normal - Normal measurement configurations (default)
+ positivebias - Positive bias configuration
+ negativebias - Negative bias configuration
+ disabled - Only available on HMC5983. Disables magnetic
+ sensor and enables temperature sensor.
+ Note: The effect of this configuration may vary
+ according to the device. For exact documentation
+ check the device's datasheet.