summaryrefslogtreecommitdiffstats
path: root/Documentation/admin-guide
diff options
context:
space:
mode:
authorLinus Torvalds <torvalds@linux-foundation.org>2017-02-20 18:54:46 +0100
committerLinus Torvalds <torvalds@linux-foundation.org>2017-02-20 18:54:46 +0100
commit345fb0a9a6340ba0b3b714d62f877fde88c8a755 (patch)
treebd5fb44a0d8e8ab00a7d3b07470de725e6cc7026 /Documentation/admin-guide
parentMerge tag 'hwmon-for-linus-v4.11' of git://git.kernel.org/pub/scm/linux/kerne... (diff)
parentEDAC, mce_amd: Print IPID and Syndrome on a separate line (diff)
downloadlinux-345fb0a9a6340ba0b3b714d62f877fde88c8a755.tar.xz
linux-345fb0a9a6340ba0b3b714d62f877fde88c8a755.zip
Merge tag 'edac_for_4.11' of git://git.kernel.org/pub/scm/linux/kernel/git/bp/bp
Pull EDAC updates from Borislav Petkov: - Make amd64_edac still load on a machine with unpopulated nodes + cleanups (Yazen Ghannam) - Expose per-DIMM error counts in sysfs (Aaron Miller) - Add T2080 l2-cache support to mpc85xx (Chris Packham) - Random other small improvements/cleanups/fixlets * tag 'edac_for_4.11' of git://git.kernel.org/pub/scm/linux/kernel/git/bp/bp: EDAC, mce_amd: Print IPID and Syndrome on a separate line EDAC, amd64: Bump driver version MAINTAINERS, EDAC: Update email for Thor Thayer EDAC, fsl_ddr: Make locally used symbols static EDAC, mpc85xx: Add T2080 l2-cache support EDAC, amd64: Add x86cpuid sanity check during init EDAC, amd64: Don't treat ECC disabled as failure EDAC: Add routine to check if MC devices list is empty EDAC, amd64: Remove unused printing macros EDAC, amd64: Rework messages in ecc_enabled() EDAC, amd64: Move global code out of instance functions EDAC, amd64: Free unused memory when init_one_instance() fails EDAC, mce_amd: Give more context to deferred error message EDAC, i7300: Test for the second channel properly EDAC, sb_edac: Get rid of ->show_interleave_mode() EDAC: Expose per-DIMM error counts in sysfs EDAC, amd64: Save and return err code from probe_one_instance() EDAC, i82975x: Add ioremap_nocache() error handling EDAC: Fix typos in enum mem_type comments EDAC: Make dev_attr_sdram_scrub_rate static
Diffstat (limited to 'Documentation/admin-guide')
-rw-r--r--Documentation/admin-guide/ras.rst20
1 files changed, 20 insertions, 0 deletions
diff --git a/Documentation/admin-guide/ras.rst b/Documentation/admin-guide/ras.rst
index d71340e86c27..9939348bd4a3 100644
--- a/Documentation/admin-guide/ras.rst
+++ b/Documentation/admin-guide/ras.rst
@@ -438,11 +438,13 @@ A typical EDAC system has the following structure under
│   │   ├── ce_count
│   │   ├── ce_noinfo_count
│   │   ├── dimm0
+ │   │   │   ├── dimm_ce_count
│   │   │   ├── dimm_dev_type
│   │   │   ├── dimm_edac_mode
│   │   │   ├── dimm_label
│   │   │   ├── dimm_location
│   │   │   ├── dimm_mem_type
+ │   │   │   ├── dimm_ue_count
│   │   │   ├── size
│   │   │   └── uevent
│   │   ├── max_location
@@ -457,11 +459,13 @@ A typical EDAC system has the following structure under
│   │   ├── ce_count
│   │   ├── ce_noinfo_count
│   │   ├── dimm0
+ │   │   │   ├── dimm_ce_count
│   │   │   ├── dimm_dev_type
│   │   │   ├── dimm_edac_mode
│   │   │   ├── dimm_label
│   │   │   ├── dimm_location
│   │   │   ├── dimm_mem_type
+ │   │   │   ├── dimm_ue_count
│   │   │   ├── size
│   │   │   └── uevent
│   │   ├── max_location
@@ -483,6 +487,22 @@ this ``X`` memory module:
This attribute file displays, in count of megabytes, the memory
that this csrow contains.
+- ``dimm_ue_count`` - Uncorrectable Errors count attribute file
+
+ This attribute file displays the total count of uncorrectable
+ errors that have occurred on this DIMM. If panic_on_ue is set
+ this counter will not have a chance to increment, since EDAC
+ will panic the system.
+
+- ``dimm_ce_count`` - Correctable Errors count attribute file
+
+ This attribute file displays the total count of correctable
+ errors that have occurred on this DIMM. This count is very
+ important to examine. CEs provide early indications that a
+ DIMM is beginning to fail. This count field should be
+ monitored for non-zero values and report such information
+ to the system administrator.
+
- ``dimm_dev_type`` - Device type attribute file
This attribute file will display what type of DRAM device is