summaryrefslogtreecommitdiffstats
path: root/Documentation/bpf
diff options
context:
space:
mode:
authorMarek Vasut <marex@denx.de>2022-02-20 05:07:18 +0100
committerMaarten Lankhorst <maarten.lankhorst@linux.intel.com>2022-03-16 16:35:05 +0100
commitfc1b6ef7bfb3d1d4df868b1c3e0480cacda6cd81 (patch)
tree22e691731209edff62d6540b35fe0ecfef4f493f /Documentation/bpf
parentdrm/imx: parallel-display: Remove bus flags check in imx_pd_bridge_atomic_che... (diff)
downloadlinux-fc1b6ef7bfb3d1d4df868b1c3e0480cacda6cd81.tar.xz
linux-fc1b6ef7bfb3d1d4df868b1c3e0480cacda6cd81.zip
drm/panel: simple: Fix Innolux G070Y2-L01 BPP settings
The Innolux G070Y2-L01 supports two modes of operation: 1) FRC=Low/NC ... MEDIA_BUS_FMT_RGB666_1X7X3_SPWG ... BPP=6 2) FRC=High ..... MEDIA_BUS_FMT_RGB888_1X7X4_SPWG ... BPP=8 Currently the panel description mixes both, BPP from 1) and bus format from 2), which triggers a warning at panel-simple.c:615. Pick the later, set bpp=8, fix the warning. Fixes: a5d2ade627dca ("drm/panel: simple: Add support for Innolux G070Y2-L01") Signed-off-by: Marek Vasut <marex@denx.de> Cc: Christoph Fritz <chf.fritz@googlemail.com> Cc: Laurent Pinchart <Laurent.pinchart@ideasonboard.com> Cc: Maxime Ripard <maxime@cerno.tech> Cc: Sam Ravnborg <sam@ravnborg.org> Cc: Thomas Zimmermann <tzimmermann@suse.de> Reviewed-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com> Link: https://patchwork.freedesktop.org/patch/msgid/20220220040718.532866-1-marex@denx.de Signed-off-by: Maarten Lankhorst <maarten.lankhorst@linux.intel.com>
Diffstat (limited to 'Documentation/bpf')
0 files changed, 0 insertions, 0 deletions