summaryrefslogtreecommitdiffstats
path: root/Documentation/devicetree/bindings/net
diff options
context:
space:
mode:
authorDinh Nguyen <dinguyen@kernel.org>2021-03-24 14:52:19 +0100
committerDavid S. Miller <davem@davemloft.net>2021-03-26 00:51:53 +0100
commit3ed14d8d47bff8cd70c357da9b72b1f698bf553b (patch)
tree096723a7046d2f52eb2d9ed91262be2565745700 /Documentation/devicetree/bindings/net
parentnet: axienet: allow setups without MDIO (diff)
downloadlinux-3ed14d8d47bff8cd70c357da9b72b1f698bf553b.tar.xz
linux-3ed14d8d47bff8cd70c357da9b72b1f698bf553b.zip
dt-bindings: net: micrel-ksz90x1.txt: correct documentation
Correct the Micrel phy documentation for the ksz9021 and ksz9031 phys for how the phy skews are set. Signed-off-by: Dinh Nguyen <dinguyen@kernel.org> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'Documentation/devicetree/bindings/net')
-rw-r--r--Documentation/devicetree/bindings/net/micrel-ksz90x1.txt96
1 files changed, 94 insertions, 2 deletions
diff --git a/Documentation/devicetree/bindings/net/micrel-ksz90x1.txt b/Documentation/devicetree/bindings/net/micrel-ksz90x1.txt
index b921731cd970..df9e844dd6bc 100644
--- a/Documentation/devicetree/bindings/net/micrel-ksz90x1.txt
+++ b/Documentation/devicetree/bindings/net/micrel-ksz90x1.txt
@@ -65,6 +65,71 @@ KSZ9031:
step is 60ps. The default value is the neutral setting, so setting
rxc-skew-ps=<0> actually results in -900 picoseconds adjustment.
+ The KSZ9031 hardware supports a range of skew values from negative to
+ positive, where the specific range is property dependent. All values
+ specified in the devicetree are offset by the minimum value so they
+ can be represented as positive integers in the devicetree since it's
+ difficult to represent a negative number in the devictree.
+
+ The following 5-bit values table apply to rxc-skew-ps and txc-skew-ps.
+
+ Pad Skew Value Delay (ps) Devicetree Value
+ ------------------------------------------------------
+ 0_0000 -900ps 0
+ 0_0001 -840ps 60
+ 0_0010 -780ps 120
+ 0_0011 -720ps 180
+ 0_0100 -660ps 240
+ 0_0101 -600ps 300
+ 0_0110 -540ps 360
+ 0_0111 -480ps 420
+ 0_1000 -420ps 480
+ 0_1001 -360ps 540
+ 0_1010 -300ps 600
+ 0_1011 -240ps 660
+ 0_1100 -180ps 720
+ 0_1101 -120ps 780
+ 0_1110 -60ps 840
+ 0_1111 0ps 900
+ 1_0000 60ps 960
+ 1_0001 120ps 1020
+ 1_0010 180ps 1080
+ 1_0011 240ps 1140
+ 1_0100 300ps 1200
+ 1_0101 360ps 1260
+ 1_0110 420ps 1320
+ 1_0111 480ps 1380
+ 1_1000 540ps 1440
+ 1_1001 600ps 1500
+ 1_1010 660ps 1560
+ 1_1011 720ps 1620
+ 1_1100 780ps 1680
+ 1_1101 840ps 1740
+ 1_1110 900ps 1800
+ 1_1111 960ps 1860
+
+ The following 4-bit values table apply to the txdX-skew-ps, rxdX-skew-ps
+ data pads, and the rxdv-skew-ps, txen-skew-ps control pads.
+
+ Pad Skew Value Delay (ps) Devicetree Value
+ ------------------------------------------------------
+ 0000 -420ps 0
+ 0001 -360ps 60
+ 0010 -300ps 120
+ 0011 -240ps 180
+ 0100 -180ps 240
+ 0101 -120ps 300
+ 0110 -60ps 360
+ 0111 0ps 420
+ 1000 60ps 480
+ 1001 120ps 540
+ 1010 180ps 600
+ 1011 240ps 660
+ 1100 300ps 720
+ 1101 360ps 780
+ 1110 420ps 840
+ 1111 480ps 900
+
Optional properties:
Maximum value of 1860, default value 900:
@@ -120,11 +185,21 @@ KSZ9131:
Examples:
+ /* Attach to an Ethernet device with autodetected PHY */
+ &enet {
+ rxc-skew-ps = <1800>;
+ rxdv-skew-ps = <0>;
+ txc-skew-ps = <1800>;
+ txen-skew-ps = <0>;
+ status = "okay";
+ };
+
+ /* Attach to an explicitly-specified PHY */
mdio {
phy0: ethernet-phy@0 {
- rxc-skew-ps = <3000>;
+ rxc-skew-ps = <1800>;
rxdv-skew-ps = <0>;
- txc-skew-ps = <3000>;
+ txc-skew-ps = <1800>;
txen-skew-ps = <0>;
reg = <0>;
};
@@ -133,3 +208,20 @@ Examples:
phy = <&phy0>;
phy-mode = "rgmii-id";
};
+
+References
+
+ Micrel ksz9021rl/rn Data Sheet, Revision 1.2. Dated 2/13/2014.
+ http://www.micrel.com/_PDF/Ethernet/datasheets/ksz9021rl-rn_ds.pdf
+
+ Micrel ksz9031rnx Data Sheet, Revision 2.1. Dated 11/20/2014.
+ http://www.micrel.com/_PDF/Ethernet/datasheets/KSZ9031RNX.pdf
+
+Notes:
+
+ Note that a previous version of the Micrel ksz9021rl/rn Data Sheet
+ was missing extended register 106 (transmit data pad skews), and
+ incorrectly specified the ps per step as 200ps/step instead of
+ 120ps/step. The latest update to this document reflects the latest
+ revision of the Micrel specification even though usage in the kernel
+ still reflects that incorrect document.