hwmon: (adt7475) fan stall prevention
By default adt7475 will stop the fans (pwm duty cycle 0%) when the
temperature drops past Tmin - hysteresis. Some systems want to keep the
fans moving even when the temperature drops so add new sysfs attributes
that configure the enhanced acoustics min 1-3 which allows the fans to
run at the minimum configure pwm duty cycle.
Signed-off-by: Chris Packham <chris.packham@alliedtelesis.co.nz>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'Documentation/hwmon/adt7475')
-rw-r--r-- | Documentation/hwmon/adt7475 | 5 |
1 files changed, 5 insertions, 0 deletions
diff --git a/Documentation/hwmon/adt7475 b/Documentation/hwmon/adt7475 index 0502f2b464e1..dc0b55794c47 100644 --- a/Documentation/hwmon/adt7475 +++ b/Documentation/hwmon/adt7475 @@ -109,6 +109,11 @@ fan speed) is applied. PWM values range from 0 (off) to 255 (full speed). Fan speed may be set to maximum when the temperature sensor associated with the PWM control exceeds temp#_max. +At Tmin - hysteresis the PWM output can either be off (0% duty cycle) or at the +minimum (i.e. auto_point1_pwm). This behaviour can be configured using the +pwm[1-*]_stall_disable sysfs attribute. A value of 0 means the fans will shut +off. A value of 1 means the fans will run at auto_point1_pwm. + Notes ----- |