diff options
author | Mauro Carvalho Chehab <mchehab+samsung@kernel.org> | 2019-04-17 11:46:29 +0200 |
---|---|---|
committer | Guenter Roeck <linux@roeck-us.net> | 2019-04-17 19:37:23 +0200 |
commit | 7ebd8b66dd9e5a0b65e5ee5e2b8e7ca382ec97b7 (patch) | |
tree | 9db30159bd32bec125c7d49e80a79bb7c4da0c8e /Documentation/hwmon/lm95245 | |
parent | docs: hwmon: convert remaining files to ReST format (diff) | |
download | linux-7ebd8b66dd9e5a0b65e5ee5e2b8e7ca382ec97b7.tar.xz linux-7ebd8b66dd9e5a0b65e5ee5e2b8e7ca382ec97b7.zip |
docs: hwmon: Add an index file and rename docs to *.rst
Now that all files were converted to ReST format, rename them
and add an index.
Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'Documentation/hwmon/lm95245')
-rw-r--r-- | Documentation/hwmon/lm95245 | 48 |
1 files changed, 0 insertions, 48 deletions
diff --git a/Documentation/hwmon/lm95245 b/Documentation/hwmon/lm95245 deleted file mode 100644 index 566d1dc8c5a6..000000000000 --- a/Documentation/hwmon/lm95245 +++ /dev/null @@ -1,48 +0,0 @@ -Kernel driver lm95245 -===================== - -Supported chips: - - * TI LM95235 - - Addresses scanned: I2C 0x18, 0x29, 0x4c - - Datasheet: Publicly available at the TI website - - http://www.ti.com/lit/ds/symlink/lm95235.pdf - - * TI / National Semiconductor LM95245 - - Addresses scanned: I2C 0x18, 0x19, 0x29, 0x4c, 0x4d - - Datasheet: Publicly available at the TI website - - http://www.ti.com/lit/ds/symlink/lm95245.pdf - -Author: Alexander Stein <alexander.stein@systec-electronic.com> - -Description ------------ - -LM95235 and LM95245 are 11-bit digital temperature sensors with a 2-wire System -Management Bus (SMBus) interface and TruTherm technology that can monitor -the temperature of a remote diode as well as its own temperature. -The chips can be used to very accurately monitor the temperature of -external devices such as microprocessors. - -All temperature values are given in millidegrees Celsius. Local temperature -is given within a range of -127 to +127.875 degrees. Remote temperatures are -given within a range of -127 to +255 degrees. Resolution depends on -temperature input and range. - -Each sensor has its own critical limit. Additionally, there is a relative -hysteresis value common to both critical limits. To make life easier to -user-space applications, two absolute values are exported, one for each -channel, but these values are of course linked. Only the local hysteresis -can be set from user-space, and the same delta applies to the remote -hysteresis. - -The lm95245 driver can change its update interval to a fixed set of values. -It will round up to the next selectable interval. See the datasheet for exact -values. Reading sensor values more often will do no harm, but will return -'old' values. |