summaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon
diff options
context:
space:
mode:
authorNavin Sankar Velliangiri <navin@linumiz.com>2021-05-24 16:20:38 +0200
committerGuenter Roeck <linux@roeck-us.net>2021-06-17 13:21:45 +0200
commit505c2549373f3aa9ee16493f872e57876ffb70b1 (patch)
tree6b48ea11b9eabd661a5e01eb5ceaf86acbb5ffd5 /Documentation/hwmon
parentdocs: hwmon: Add an entry for mp2888 (diff)
downloadlinux-505c2549373f3aa9ee16493f872e57876ffb70b1.tar.xz
linux-505c2549373f3aa9ee16493f872e57876ffb70b1.zip
hwmon: Add sht4x Temperature and Humidity Sensor Driver
This patch adds a hwmon driver for the SHT4x Temperature and Humidity sensor. Signed-off-by: Navin Sankar Velliangiri <navin@linumiz.com> [groeck: dropped unnecessary empty line and continuation lines] Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r--Documentation/hwmon/index.rst1
-rw-r--r--Documentation/hwmon/sht4x.rst45
2 files changed, 46 insertions, 0 deletions
diff --git a/Documentation/hwmon/index.rst b/Documentation/hwmon/index.rst
index 6925a8a70511..61e5d4532622 100644
--- a/Documentation/hwmon/index.rst
+++ b/Documentation/hwmon/index.rst
@@ -165,6 +165,7 @@ Hardware Monitoring Kernel Drivers
sht15
sht21
sht3x
+ sht4x
shtc1
sis5595
sl28cpld
diff --git a/Documentation/hwmon/sht4x.rst b/Documentation/hwmon/sht4x.rst
new file mode 100644
index 000000000000..3b37abcd4a46
--- /dev/null
+++ b/Documentation/hwmon/sht4x.rst
@@ -0,0 +1,45 @@
+.. SPDX-License-Identifier: GPL-2.0
+
+Kernel driver sht4x
+===================
+
+Supported Chips:
+
+ * Sensirion SHT4X
+
+ Prefix: 'sht4x'
+
+ Addresses scanned: None
+
+ Datasheet:
+
+ English: https://www.sensirion.com/fileadmin/user_upload/customers/sensirion/Dokumente/2_Humidity_Sensors/Datasheets/Sensirion_Humidity_Sensors_SHT4x_Datasheet.pdf
+
+Author: Navin Sankar Velliangiri <navin@linumiz.com>
+
+
+Description
+-----------
+
+This driver implements support for the Sensirion SHT4x chip, a humidity
+and temperature sensor. Temperature is measured in degree celsius, relative
+humidity is expressed as a percentage. In sysfs interface, all values are
+scaled by 1000, i.e. the value for 31.5 degrees celsius is 31500.
+
+Usage Notes
+-----------
+
+The device communicates with the I2C protocol. Sensors can have the I2C
+address 0x44. See Documentation/i2c/instantiating-devices.rst for methods
+to instantiate the device.
+
+Sysfs entries
+-------------
+
+=============== ============================================
+temp1_input Measured temperature in millidegrees Celcius
+humidity1_input Measured humidity in %H
+update_interval The minimum interval for polling the sensor,
+ in milliseconds. Writable. Must be at least
+ 2000.
+============== =============================================