summaryrefslogtreecommitdiffstats
path: root/Documentation/i2c
diff options
context:
space:
mode:
authorWolfram Sang <wsa+renesas@sang-engineering.com>2018-06-29 11:12:47 +0200
committerWolfram Sang <wsa@the-dreams.de>2018-07-03 23:09:36 +0200
commitbbe899700a44af8b81dcef49f4005d9d1afe7c47 (patch)
treed9897ddec44388b3194c2a411221a1cf392a9f11 /Documentation/i2c
parenti2c: gpio: fault-injector: refactor incomplete transfer (diff)
downloadlinux-bbe899700a44af8b81dcef49f4005d9d1afe7c47.tar.xz
linux-bbe899700a44af8b81dcef49f4005d9d1afe7c47.zip
i2c: gpio: fault-injector: add incomplete_write_byte
Add another injector for an incomplete transfer. As mentioned in the docs, this one is important to check bus recovery algorithms with it. Otherwise random data may be sent to devices! Signed-off-by: Wolfram Sang <wsa+renesas@sang-engineering.com> Signed-off-by: Wolfram Sang <wsa@the-dreams.de>
Diffstat (limited to 'Documentation/i2c')
-rw-r--r--Documentation/i2c/gpio-fault-injection19
1 files changed, 19 insertions, 0 deletions
diff --git a/Documentation/i2c/gpio-fault-injection b/Documentation/i2c/gpio-fault-injection
index 37542461cea4..a4ce62090fd5 100644
--- a/Documentation/i2c/gpio-fault-injection
+++ b/Documentation/i2c/gpio-fault-injection
@@ -60,3 +60,22 @@ above, the bus master under test should detect this condition and try a bus
recovery. This time, however, it should succeed and the device should release
SDA after toggling SCL.
+"incomplete_write_byte"
+-----------------------
+
+Similar to above, this file is write only and you need to write the address of
+an existing I2C client device to it.
+
+The injector will again stop at one ACK phase, so the device will keep SDA low
+because it acknowledges data. However, there are two differences compared to
+'incomplete_address_phase':
+
+a) the message sent out will be a write message
+b) after the address byte, a 0x00 byte will be transferred. Then, stop at ACK.
+
+This is a highly delicate state, the device is set up to write any data to
+register 0x00 (if it has registers) when further clock pulses happen on SCL.
+This is why bus recovery (up to 9 clock pulses) must either check SDA or send
+additional STOP conditions to ensure the bus has been released. Otherwise
+random data will be written to a device!
+