authorRoderick Colenbrander <roderick.colenbrander@sony.com>2017-03-08 00:45:00 +0100
committerJiri Kosina <jkosina@suse.cz>2017-03-21 15:11:32 +0100
commit227c011b2e046dd4d36d9e00e3d9c88097b2a4c3 (patch)
tree01d851c728388f115f941de1cd8ff5040e1d49d4 /Documentation/input
parentHID: sony: Use LED_CORE_SUSPENDRESUME (diff)
downloadlinux-227c011b2e046dd4d36d9e00e3d9c88097b2a4c3.tar.xz
linux-227c011b2e046dd4d36d9e00e3d9c88097b2a4c3.zip
HID: sony: Report DS4 motion sensors through a separate device
The DS4 motion sensors are currently mapped by the hid-core driver to non-existing axes in between ABS_MISC and ABS_MT_SLOT, because the device already exhausted ABS_X-ABS_RZ. For a part the mapping by hid-core is accomplished by a fixup in hid-sony as the motion axes actually use vendor specific usage pages. This patch makes the DS4 use a separate input device for the motion sensors and reports acceleration data through ABS_X-ABS_Z and gyroscope data through ABS_RX-ABS_RZ. In addition it extends the event spec to allow gyroscope data through ABS_RX-ABS_RZ when INPUT_PROP_ACCELEROMETER is set. This change was suggested by Peter Hutterer during a discussion on linux-input. [jkosina@suse.cz: rebase onto slightly newer codebase] Signed-off-by: Roderick Colenbrander <roderick.colenbrander@sony.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Diffstat (limited to 'Documentation/input')
-rw-r--r--Documentation/input/event-codes.txt5
1 files changed, 4 insertions, 1 deletions
diff --git a/Documentation/input/event-codes.txt b/Documentation/input/event-codes.txt
index 36ea940e5bb9..575415f4cef0 100644
--- a/Documentation/input/event-codes.txt
+++ b/Documentation/input/event-codes.txt
@@ -301,7 +301,10 @@ them as any other INPUT_PROP_BUTTONPAD device.
INPUT_PROP_ACCELEROMETER
-------------------------
Directional axes on this device (absolute and/or relative x, y, z) represent
-accelerometer data. All other axes retain their meaning. A device must not mix
+accelerometer data. Some devices also report gyroscope data, which devices
+can report through the rotational axes (absolute and/or relative rx, ry, rz).
+
+All other axes retain their meaning. A device must not mix
regular directional axes and accelerometer axes on the same event node.
Guidelines: