summaryrefslogtreecommitdiffstats
path: root/Documentation/power/devices.txt
diff options
context:
space:
mode:
authorRafael J. Wysocki <rjw@sisk.pl>2011-06-23 01:52:55 +0200
committerRafael J. Wysocki <rjw@sisk.pl>2011-07-02 14:29:54 +0200
commit564b905ab10d17fb42f86aa8b7b9b796276d1336 (patch)
treeb191c000e55ae1a354bd67876ca6945d2ad87c93 /Documentation/power/devices.txt
parentPM / Runtime: Update documentation regarding driver removal (diff)
downloadlinux-564b905ab10d17fb42f86aa8b7b9b796276d1336.tar.xz
linux-564b905ab10d17fb42f86aa8b7b9b796276d1336.zip
PM / Domains: Rename struct dev_power_domain to struct dev_pm_domain
The naming convention used by commit 7538e3db6e015e890825fbd9f86599b (PM: Add support for device power domains), which introduced the struct dev_power_domain type for representing device power domains, evidently confuses some developers who tend to think that objects of this type must correspond to "power domains" as defined by hardware, which is not the case. Namely, at the kernel level, a struct dev_power_domain object can represent arbitrary set of devices that are mutually dependent power management-wise and need not belong to one hardware power domain. To avoid that confusion, rename struct dev_power_domain to struct dev_pm_domain and rename the related pointers in struct device and struct pm_clk_notifier_block from pwr_domain to pm_domain. Signed-off-by: Rafael J. Wysocki <rjw@sisk.pl> Acked-by: Kevin Hilman <khilman@ti.com>
Diffstat (limited to 'Documentation/power/devices.txt')
-rw-r--r--Documentation/power/devices.txt8
1 files changed, 4 insertions, 4 deletions
diff --git a/Documentation/power/devices.txt b/Documentation/power/devices.txt
index 64565aac6e40..85c6f980b642 100644
--- a/Documentation/power/devices.txt
+++ b/Documentation/power/devices.txt
@@ -506,8 +506,8 @@ routines. Nevertheless, different callback pointers are used in case there is a
situation where it actually matters.
-Device Power Domains
---------------------
+Device Power Management Domains
+-------------------------------
Sometimes devices share reference clocks or other power resources. In those
cases it generally is not possible to put devices into low-power states
individually. Instead, a set of devices sharing a power resource can be put
@@ -516,8 +516,8 @@ power resource. Of course, they also need to be put into the full-power state
together, by turning the shared power resource on. A set of devices with this
property is often referred to as a power domain.
-Support for power domains is provided through the pwr_domain field of struct
-device. This field is a pointer to an object of type struct dev_power_domain,
+Support for power domains is provided through the pm_domain field of struct
+device. This field is a pointer to an object of type struct dev_pm_domain,
defined in include/linux/pm.h, providing a set of power management callbacks
analogous to the subsystem-level and device driver callbacks that are executed
for the given device during all power transitions, instead of the respective