PM: EM: Clarify abstract scale usage for power values in Energy Model
The Energy Model (EM) can store power values in milli-Watts or in abstract
scale. This might cause issues in the subsystems which use the EM for
estimating the device power, such as:
- mixing of different scales in a subsystem which uses multiple
(cooling) devices (e.g. thermal Intelligent Power Allocation (IPA))
- assuming that energy [milli-Joules] can be derived from the EM power
values which might not be possible since the power scale doesn't have
to be in milli-Watts
To avoid misconfiguration add the requisite documentation to the EM and
related subsystems: EAS and IPA.
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Diffstat (limited to 'Documentation/power/energy-model.rst')
-rw-r--r-- | Documentation/power/energy-model.rst | 13 |
1 files changed, 13 insertions, 0 deletions
diff --git a/Documentation/power/energy-model.rst b/Documentation/power/energy-model.rst index a6fb986abe3c..ba7aa581b307 100644 --- a/Documentation/power/energy-model.rst +++ b/Documentation/power/energy-model.rst @@ -20,6 +20,19 @@ possible source of information on its own, the EM framework intervenes as an abstraction layer which standardizes the format of power cost tables in the kernel, hence enabling to avoid redundant work. +The power values might be expressed in milli-Watts or in an 'abstract scale'. +Multiple subsystems might use the EM and it is up to the system integrator to +check that the requirements for the power value scale types are met. An example +can be found in the Energy-Aware Scheduler documentation +Documentation/scheduler/sched-energy.rst. For some subsystems like thermal or +powercap power values expressed in an 'abstract scale' might cause issues. +These subsystems are more interested in estimation of power used in the past, +thus the real milli-Watts might be needed. An example of these requirements can +be found in the Intelligent Power Allocation in +Documentation/driver-api/thermal/power_allocator.rst. +Important thing to keep in mind is that when the power values are expressed in +an 'abstract scale' deriving real energy in milli-Joules would not be possible. + The figure below depicts an example of drivers (Arm-specific here, but the approach is applicable to any architecture) providing power costs to the EM framework, and interested clients reading the data from it:: |