thermal: of: fix cooling device weights in device tree
Currently you can specify the weight of the cooling device in the device
tree but that information is not populated to the
thermal_bind_params where the fair share governor expects it to
be. The of thermal zone device doesn't have a thermal_bind_params
structure and arguably it's better to pass the weight inside the
thermal_instance as it is specific to the bind of a cooling device to a
thermal zone parameter.
Core thermal code is fixed to populate the weight in the instance from
the thermal_bind_params, so platform code that was passing the weight
inside the thermal_bind_params continue to work seamlessly.
While we are at it, create a default value for the weight parameter for
those thermal zones that currently don't define it and remove the
hardcoded default in of-thermal.
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: "Rafael J. Wysocki" <rjw@rjwysocki.net>
Cc: Len Brown <lenb@kernel.org>
Cc: Peter Feuerer <peter@piie.net>
Cc: Darren Hart <dvhart@infradead.org>
Cc: Eduardo Valentin <edubezval@gmail.com>
Cc: Kukjin Kim <kgene@kernel.org>
Cc: Durgadoss R <durgadoss.r@intel.com>
Signed-off-by: Kapileshwar Singh <kapileshwar.singh@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Diffstat (limited to 'Documentation/thermal/sysfs-api.txt')
-rw-r--r-- | Documentation/thermal/sysfs-api.txt | 4 |
1 files changed, 3 insertions, 1 deletions
diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt index 87519cb379ee..7ec632ed9769 100644 --- a/Documentation/thermal/sysfs-api.txt +++ b/Documentation/thermal/sysfs-api.txt @@ -95,7 +95,7 @@ temperature) and throttle appropriate devices. 1.3 interface for binding a thermal zone device with a thermal cooling device 1.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz, int trip, struct thermal_cooling_device *cdev, - unsigned long upper, unsigned long lower); + unsigned long upper, unsigned long lower, unsigned int weight); This interface function bind a thermal cooling device to the certain trip point of a thermal zone device. @@ -110,6 +110,8 @@ temperature) and throttle appropriate devices. lower:the Minimum cooling state can be used for this trip point. THERMAL_NO_LIMIT means no lower limit, and the cooling device can be in cooling state 0. + weight: the influence of this cooling device in this thermal + zone. See 1.4.1 below for more information. 1.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz, int trip, struct thermal_cooling_device *cdev); |