summaryrefslogtreecommitdiffstats
path: root/Documentation
diff options
context:
space:
mode:
authorViresh Kumar <viresh.kumar@linaro.org>2018-02-09 09:58:10 +0100
committerEduardo Valentin <edubezval@gmail.com>2018-04-18 16:04:28 +0200
commite04907dbc25930b88ee2328fe692c776f63ddf2c (patch)
treecb42b150a52b62e6e101b0b47b805e5939d3c12c /Documentation
parentdt-bindings: thermal: remove no longer needed samsung thermal properties (diff)
downloadlinux-e04907dbc25930b88ee2328fe692c776f63ddf2c.tar.xz
linux-e04907dbc25930b88ee2328fe692c776f63ddf2c.zip
dt-bindings: thermal: Remove "cooling-{min|max}-level" properties
The "cooling-min-level" and "cooling-max-level" properties are not parsed by any part of kernel currently and the max cooling state of a CPU cooling device is found by referring to the cpufreq table instead. Remove the unused bindings. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Reviewed-by: Rob Herring <robh@kernel.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/devicetree/bindings/thermal/thermal.txt16
1 files changed, 1 insertions, 15 deletions
diff --git a/Documentation/devicetree/bindings/thermal/thermal.txt b/Documentation/devicetree/bindings/thermal/thermal.txt
index 1719d47a5e2f..cc553f0952c5 100644
--- a/Documentation/devicetree/bindings/thermal/thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/thermal.txt
@@ -55,8 +55,7 @@ of heat dissipation). For example a fan's cooling states correspond to
the different fan speeds possible. Cooling states are referred to by
single unsigned integers, where larger numbers mean greater heat
dissipation. The precise set of cooling states associated with a device
-(as referred to by the cooling-min-level and cooling-max-level
-properties) should be defined in a particular device's binding.
+should be defined in a particular device's binding.
For more examples of cooling devices, refer to the example sections below.
Required properties:
@@ -69,15 +68,6 @@ Required properties:
See Cooling device maps section below for more details
on how consumers refer to cooling devices.
-Optional properties:
-- cooling-min-level: An integer indicating the smallest
- Type: unsigned cooling state accepted. Typically 0.
- Size: one cell
-
-- cooling-max-level: An integer indicating the largest
- Type: unsigned cooling state accepted.
- Size: one cell
-
* Trip points
The trip node is a node to describe a point in the temperature domain
@@ -226,8 +216,6 @@ cpus {
396000 950000
198000 850000
>;
- cooling-min-level = <0>;
- cooling-max-level = <3>;
#cooling-cells = <2>; /* min followed by max */
};
...
@@ -241,8 +229,6 @@ cpus {
*/
fan0: fan@48 {
...
- cooling-min-level = <0>;
- cooling-max-level = <9>;
#cooling-cells = <2>; /* min followed by max */
};
};