diff options
author | Guenter Roeck <linux@roeck-us.net> | 2013-02-06 18:55:37 +0100 |
---|---|---|
committer | Guenter Roeck <linux@roeck-us.net> | 2013-04-08 06:16:41 +0200 |
commit | a7c69118bdc8647db0e15defa9e399df21a48890 (patch) | |
tree | d0838283520993eee5a014b6a54bab8e79169d63 /Documentation | |
parent | hwmon: (max6697) Use is_visible and sysfs_create_group (diff) | |
download | linux-a7c69118bdc8647db0e15defa9e399df21a48890.tar.xz linux-a7c69118bdc8647db0e15defa9e399df21a48890.zip |
hwmon: (pmbus/lm25066) Report VAUX as vmon
So far the driver reported the voltage on VAUX as "vout2". This was not
entirely appropriate as it is not an output voltage, and complicates
the code. Use the new virtual "VMON" register set and report the voltage
as "vmon" instead.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'Documentation')
-rw-r--r-- | Documentation/hwmon/lm25066 | 16 |
1 files changed, 8 insertions, 8 deletions
diff --git a/Documentation/hwmon/lm25066 b/Documentation/hwmon/lm25066 index 26025e419d35..2bc5ba6aee66 100644 --- a/Documentation/hwmon/lm25066 +++ b/Documentation/hwmon/lm25066 @@ -60,14 +60,14 @@ in1_max Maximum input voltage. in1_min_alarm Input voltage low alarm. in1_max_alarm Input voltage high alarm. -in2_label "vout1" -in2_input Measured output voltage. -in2_average Average measured output voltage. -in2_min Minimum output voltage. -in2_min_alarm Output voltage low alarm. - -in3_label "vout2" -in3_input Measured voltage on vaux pin +in2_label "vmon" +in2_input Measured voltage on VAUX pin + +in3_label "vout1" +in3_input Measured output voltage. +in3_average Average measured output voltage. +in3_min Minimum output voltage. +in3_min_alarm Output voltage low alarm. curr1_label "iin" curr1_input Measured input current. |