diff options
author | Mauro Carvalho Chehab <mchehab+huawei@kernel.org> | 2020-10-30 08:40:54 +0100 |
---|---|---|
committer | Greg Kroah-Hartman <gregkh@linuxfoundation.org> | 2020-10-30 13:14:50 +0100 |
commit | 9e0b29adfb3323ffd250b74373c68209e291b8e5 (patch) | |
tree | ee5748d03a03a3be691be6b09d251031ca2ac8fd /Documentation | |
parent | docs: ABI: unify /sys/class/leds/<led>/brightness documentation (diff) | |
download | linux-9e0b29adfb3323ffd250b74373c68209e291b8e5.tar.xz linux-9e0b29adfb3323ffd250b74373c68209e291b8e5.zip |
docs: ABI: sysfs-class-power: unify duplicated properties
The ABI is not supposed to have duplicated entries, as warned
by get_abi.pl:
$ ./scripts/get_abi.pl validate 2>&1|grep sysfs-class-power
Warning: /sys/class/power_supply/<supply_name>/current_avg is defined 2 times: Documentation/ABI/testing/sysfs-class-power:108 Documentation/ABI/testing/sysfs-class-power:391
Warning: /sys/class/power_supply/<supply_name>/current_max is defined 2 times: Documentation/ABI/testing/sysfs-class-power:121 Documentation/ABI/testing/sysfs-class-power:404
Warning: /sys/class/power_supply/<supply_name>/current_now is defined 2 times: Documentation/ABI/testing/sysfs-class-power:130 Documentation/ABI/testing/sysfs-class-power:414
Warning: /sys/class/power_supply/<supply_name>/temp is defined 2 times: Documentation/ABI/testing/sysfs-class-power:281 Documentation/ABI/testing/sysfs-class-power:493
Warning: /sys/class/power_supply/<supply_name>/temp_alert_max is defined 2 times: Documentation/ABI/testing/sysfs-class-power:291 Documentation/ABI/testing/sysfs-class-power:505
Warning: /sys/class/power_supply/<supply_name>/temp_alert_min is defined 2 times: Documentation/ABI/testing/sysfs-class-power:306 Documentation/ABI/testing/sysfs-class-power:521
Warning: /sys/class/power_supply/<supply_name>/temp_max is defined 2 times: Documentation/ABI/testing/sysfs-class-power:322 Documentation/ABI/testing/sysfs-class-power:537
Warning: /sys/class/power_supply/<supply_name>/temp_min is defined 2 times: Documentation/ABI/testing/sysfs-class-power:333 Documentation/ABI/testing/sysfs-class-power:547
Warning: /sys/class/power_supply/<supply_name>/voltage_max is defined 2 times: Documentation/ABI/testing/sysfs-class-power:356 Documentation/ABI/testing/sysfs-class-power:571
Warning: /sys/class/power_supply/<supply_name>/voltage_min is defined 2 times: Documentation/ABI/testing/sysfs-class-power:367 Documentation/ABI/testing/sysfs-class-power:581
Warning: /sys/class/power_supply/<supply_name>/voltage_now is defined 2 times: Documentation/ABI/testing/sysfs-class-power:378 Documentation/ABI/testing/sysfs-class-power:591
Yet, both USB and Battery share a common set of charging-related
properties.
Unify the entries for such properties in order to avoid
duplication, while preserving the battery and USB-specific
data properly documented.
Acked-by: Jonathan Corbet <corbet@lwn.net>
Signed-off-by: Mauro Carvalho Chehab <mchehab+huawei@kernel.org>
Link: https://lore.kernel.org/r/bcdf5f76326ea48a990a7cac612af216c387537d.1604042072.git.mchehab+huawei@kernel.org
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Diffstat (limited to 'Documentation')
-rw-r--r-- | Documentation/ABI/testing/sysfs-class-power | 486 |
1 files changed, 223 insertions, 263 deletions
diff --git a/Documentation/ABI/testing/sysfs-class-power b/Documentation/ABI/testing/sysfs-class-power index d68ad528a8e5..ca830c6cd809 100644 --- a/Documentation/ABI/testing/sysfs-class-power +++ b/Documentation/ABI/testing/sysfs-class-power @@ -36,7 +36,229 @@ Description: Access: Read Valid values: "Battery", "UPS", "Mains", "USB", "Wireless" -===== Battery Properties ===== +**Battery and USB properties** + +What: /sys/class/power_supply/<supply_name>/current_avg +Date: May 2007 +Contact: linux-pm@vger.kernel.org +Description: + Battery: + + Reports an average IBAT current reading for the battery, over + a fixed period. Normally devices will provide a fixed interval + in which they average readings to smooth out the reported + value. + + USB: + + Reports an average IBUS current reading over a fixed period. + Normally devices will provide a fixed interval in which they + average readings to smooth out the reported value. + + Access: Read + + Valid values: Represented in microamps. Negative values are + used for discharging batteries, positive values for charging + batteries and for USB IBUS current. + +What: /sys/class/power_supply/<supply_name>/current_max +Date: October 2010 +Contact: linux-pm@vger.kernel.org +Description: + Battery: + + Reports the maximum IBAT current allowed into the battery. + + USB: + + Reports the maximum IBUS current the supply can support. + + Access: Read + Valid values: Represented in microamps + +What: /sys/class/power_supply/<supply_name>/current_now +Date: May 2007 +Contact: linux-pm@vger.kernel.org +Description: + + Battery: + + Reports an instant, single IBAT current reading for the + battery. This value is not averaged/smoothed. + + Access: Read + + USB: + + Reports the IBUS current supplied now. This value is generally + read-only reporting, unless the 'online' state of the supply + is set to be programmable, in which case this value can be set + within the reported min/max range. + + Access: Read, Write + + Valid values: Represented in microamps. Negative values are + used for discharging batteries, positive values for charging + batteries and for USB IBUS current. + +What: /sys/class/power_supply/<supply_name>/temp +Date: May 2007 +Contact: linux-pm@vger.kernel.org +Description: + Battery: + + Reports the current TBAT battery temperature reading. + + USB: + + Reports the current supply temperature reading. This would + normally be the internal temperature of the device itself + (e.g TJUNC temperature of an IC) + + Access: Read + + Valid values: Represented in 1/10 Degrees Celsius + +What: /sys/class/power_supply/<supply_name>/temp_alert_max +Date: July 2012 +Contact: linux-pm@vger.kernel.org +Description: + Battery: + + Maximum TBAT temperature trip-wire value where the supply will + notify user-space of the event. + + USB: + + Maximum supply temperature trip-wire value where the supply + will notify user-space of the event. + + This is normally used for the charging scenario where + user-space needs to know if the temperature has crossed an + upper threshold so it can take appropriate action (e.g. warning + user that the temperature is critically high, and charging has + stopped). + + Access: Read + + Valid values: Represented in 1/10 Degrees Celsius + +What: /sys/class/power_supply/<supply_name>/temp_alert_min +Date: July 2012 +Contact: linux-pm@vger.kernel.org +Description: + + Battery: + + Minimum TBAT temperature trip-wire value where the supply will + notify user-space of the event. + + USB: + + Minimum supply temperature trip-wire value where the supply + will notify user-space of the event. + + This is normally used for the charging scenario where user-space + needs to know if the temperature has crossed a lower threshold + so it can take appropriate action (e.g. warning user that + temperature level is high, and charging current has been + reduced accordingly to remedy the situation). + + Access: Read + + Valid values: Represented in 1/10 Degrees Celsius + +What: /sys/class/power_supply/<supply_name>/temp_max +Date: July 2014 +Contact: linux-pm@vger.kernel.org +Description: + Battery: + + Reports the maximum allowed TBAT battery temperature for + charging. + + USB: + + Reports the maximum allowed supply temperature for operation. + + Access: Read + + Valid values: Represented in 1/10 Degrees Celsius + +What: /sys/class/power_supply/<supply_name>/temp_min +Date: July 2014 +Contact: linux-pm@vger.kernel.org +Description: + Battery: + + Reports the minimum allowed TBAT battery temperature for + charging. + + USB: + + Reports the minimum allowed supply temperature for operation. + + Access: Read + + Valid values: Represented in 1/10 Degrees Celsius + +What: /sys/class/power_supply/<supply_name>/voltage_max, +Date: January 2008 +Contact: linux-pm@vger.kernel.org +Description: + Battery: + + Reports the maximum safe VBAT voltage permitted for the + battery, during charging. + + USB: + + Reports the maximum VBUS voltage the supply can support. + + Access: Read + + Valid values: Represented in microvolts + +What: /sys/class/power_supply/<supply_name>/voltage_min, +Date: January 2008 +Contact: linux-pm@vger.kernel.org +Description: + Battery: + + Reports the minimum safe VBAT voltage permitted for the + battery, during discharging. + + USB: + + Reports the minimum VBUS voltage the supply can support. + + Access: Read + + Valid values: Represented in microvolts + +What: /sys/class/power_supply/<supply_name>/voltage_now, +Date: May 2007 +Contact: linux-pm@vger.kernel.org +Description: + Battery: + + Reports an instant, single VBAT voltage reading for the + battery. This value is not averaged/smoothed. + + Access: Read + + USB: + + Reports the VBUS voltage supplied now. This value is generally + read-only reporting, unless the 'online' state of the supply + is set to be programmable, in which case this value can be set + within the reported min/max range. + + Access: Read, Write + + Valid values: Represented in microvolts + +**Battery Properties** What: /sys/class/power_supply/<supply_name>/capacity Date: May 2007 @@ -106,40 +328,6 @@ Description: "Unknown", "Critical", "Low", "Normal", "High", "Full" -What: /sys/class/power_supply/<supply_name>/current_avg -Date: May 2007 -Contact: linux-pm@vger.kernel.org -Description: - Reports an average IBAT current reading for the battery, over a - fixed period. Normally devices will provide a fixed interval in - which they average readings to smooth out the reported value. - - Access: Read - - Valid values: Represented in microamps. Negative values are used - for discharging batteries, positive values for charging batteries. - -What: /sys/class/power_supply/<supply_name>/current_max -Date: October 2010 -Contact: linux-pm@vger.kernel.org -Description: - Reports the maximum IBAT current allowed into the battery. - - Access: Read - Valid values: Represented in microamps - -What: /sys/class/power_supply/<supply_name>/current_now -Date: May 2007 -Contact: linux-pm@vger.kernel.org -Description: - Reports an instant, single IBAT current reading for the battery. - This value is not averaged/smoothed. - - Access: Read - - Valid values: Represented in microamps. Negative values are used - for discharging batteries, positive values for charging batteries. - What: /sys/class/power_supply/<supply_name>/charge_control_limit Date: Oct 2012 Contact: linux-pm@vger.kernel.org @@ -279,68 +467,6 @@ Description: "Unknown", "NiMH", "Li-ion", "Li-poly", "LiFe", "NiCd", "LiMn" -What: /sys/class/power_supply/<supply_name>/temp -Date: May 2007 -Contact: linux-pm@vger.kernel.org -Description: - Reports the current TBAT battery temperature reading. - - Access: Read - - Valid values: Represented in 1/10 Degrees Celsius - -What: /sys/class/power_supply/<supply_name>/temp_alert_max -Date: July 2012 -Contact: linux-pm@vger.kernel.org -Description: - Maximum TBAT temperature trip-wire value where the supply will - notify user-space of the event. This is normally used for the - battery charging scenario where user-space needs to know the - battery temperature has crossed an upper threshold so it can - take appropriate action (e.g. warning user that battery level is - critically high, and charging has stopped). - - Access: Read - - Valid values: Represented in 1/10 Degrees Celsius - -What: /sys/class/power_supply/<supply_name>/temp_alert_min -Date: July 2012 -Contact: linux-pm@vger.kernel.org -Description: - Minimum TBAT temperature trip-wire value where the supply will - notify user-space of the event. This is normally used for the - battery charging scenario where user-space needs to know the - battery temperature has crossed a lower threshold so it can take - appropriate action (e.g. warning user that battery level is - high, and charging current has been reduced accordingly to - remedy the situation). - - Access: Read - - Valid values: Represented in 1/10 Degrees Celsius - -What: /sys/class/power_supply/<supply_name>/temp_max -Date: July 2014 -Contact: linux-pm@vger.kernel.org -Description: - Reports the maximum allowed TBAT battery temperature for - charging. - - Access: Read - - Valid values: Represented in 1/10 Degrees Celsius - -What: /sys/class/power_supply/<supply_name>/temp_min -Date: July 2014 -Contact: linux-pm@vger.kernel.org -Description: - Reports the minimum allowed TBAT battery temperature for - charging. - - Access: Read - - Valid values: Represented in 1/10 Degrees Celsius What: /sys/class/power_supply/<supply_name>/voltage_avg, Date: May 2007 @@ -354,77 +480,8 @@ Description: Valid values: Represented in microvolts -What: /sys/class/power_supply/<supply_name>/voltage_max, -Date: January 2008 -Contact: linux-pm@vger.kernel.org -Description: - Reports the maximum safe VBAT voltage permitted for the battery, - during charging. - - Access: Read - - Valid values: Represented in microvolts - -What: /sys/class/power_supply/<supply_name>/voltage_min, -Date: January 2008 -Contact: linux-pm@vger.kernel.org -Description: - Reports the minimum safe VBAT voltage permitted for the battery, - during discharging. - - Access: Read - - Valid values: Represented in microvolts - -What: /sys/class/power_supply/<supply_name>/voltage_now, -Date: May 2007 -Contact: linux-pm@vger.kernel.org -Description: - Reports an instant, single VBAT voltage reading for the battery. - This value is not averaged/smoothed. - - Access: Read - - Valid values: Represented in microvolts - **USB Properties** -What: /sys/class/power_supply/<supply_name>/current_avg -Date: May 2007 -Contact: linux-pm@vger.kernel.org -Description: - Reports an average IBUS current reading over a fixed period. - Normally devices will provide a fixed interval in which they - average readings to smooth out the reported value. - - Access: Read - - Valid values: Represented in microamps - - -What: /sys/class/power_supply/<supply_name>/current_max -Date: October 2010 -Contact: linux-pm@vger.kernel.org -Description: - Reports the maximum IBUS current the supply can support. - - Access: Read - - Valid values: Represented in microamps - -What: /sys/class/power_supply/<supply_name>/current_now -Date: May 2007 -Contact: linux-pm@vger.kernel.org -Description: - Reports the IBUS current supplied now. This value is generally - read-only reporting, unless the 'online' state of the supply - is set to be programmable, in which case this value can be set - within the reported min/max range. - - Access: Read, Write - - Valid values: Represented in microamps - What: /sys/class/power_supply/<supply_name>/input_current_limit Date: July 2014 Contact: linux-pm@vger.kernel.org @@ -491,70 +548,6 @@ Description: 2: Online Programmable - Programmable Voltage Supply == ================================================== -What: /sys/class/power_supply/<supply_name>/temp -Date: May 2007 -Contact: linux-pm@vger.kernel.org -Description: - Reports the current supply temperature reading. This would - normally be the internal temperature of the device itself (e.g - TJUNC temperature of an IC) - - Access: Read - - Valid values: Represented in 1/10 Degrees Celsius - -What: /sys/class/power_supply/<supply_name>/temp_alert_max -Date: July 2012 -Contact: linux-pm@vger.kernel.org -Description: - Maximum supply temperature trip-wire value where the supply will - notify user-space of the event. This is normally used for the - charging scenario where user-space needs to know the supply - temperature has crossed an upper threshold so it can take - appropriate action (e.g. warning user that the supply - temperature is critically high, and charging has stopped to - remedy the situation). - - Access: Read - - Valid values: Represented in 1/10 Degrees Celsius - -What: /sys/class/power_supply/<supply_name>/temp_alert_min -Date: July 2012 -Contact: linux-pm@vger.kernel.org -Description: - Minimum supply temperature trip-wire value where the supply will - notify user-space of the event. This is normally used for the - charging scenario where user-space needs to know the supply - temperature has crossed a lower threshold so it can take - appropriate action (e.g. warning user that the supply - temperature is high, and charging current has been reduced - accordingly to remedy the situation). - - Access: Read - - Valid values: Represented in 1/10 Degrees Celsius - -What: /sys/class/power_supply/<supply_name>/temp_max -Date: July 2014 -Contact: linux-pm@vger.kernel.org -Description: - Reports the maximum allowed supply temperature for operation. - - Access: Read - - Valid values: Represented in 1/10 Degrees Celsius - -What: /sys/class/power_supply/<supply_name>/temp_min -Date: July 2014 -Contact: linux-pm@vger.kernel.org -Description: - Reports the mainimum allowed supply temperature for operation. - - Access: Read - - Valid values: Represented in 1/10 Degrees Celsius - What: /sys/class/power_supply/<supply_name>/usb_type Date: March 2018 Contact: linux-pm@vger.kernel.org @@ -569,39 +562,6 @@ Description: "Unknown", "SDP", "DCP", "CDP", "ACA", "C", "PD", "PD_DRP", "PD_PPS", "BrickID" -What: /sys/class/power_supply/<supply_name>/voltage_max -Date: January 2008 -Contact: linux-pm@vger.kernel.org -Description: - Reports the maximum VBUS voltage the supply can support. - - Access: Read - - Valid values: Represented in microvolts - -What: /sys/class/power_supply/<supply_name>/voltage_min -Date: January 2008 -Contact: linux-pm@vger.kernel.org -Description: - Reports the minimum VBUS voltage the supply can support. - - Access: Read - - Valid values: Represented in microvolts - -What: /sys/class/power_supply/<supply_name>/voltage_now -Date: May 2007 -Contact: linux-pm@vger.kernel.org -Description: - Reports the VBUS voltage supplied now. This value is generally - read-only reporting, unless the 'online' state of the supply - is set to be programmable, in which case this value can be set - within the reported min/max range. - - Access: Read, Write - - Valid values: Represented in microvolts - **Device Specific Properties** What: /sys/class/power/ds2760-battery.*/charge_now |