scsi: qedf: Add more defensive checks for concurrent error conditions
During an uplink toggle test all error handling is done via timeout and
firmware error conditions which can occur concurrently:
- SCSI layer timeouts
- Error detect CQEs
- Firmware detected underruns
- ABTS timeouts
All these concurrent events require more defensive checks in the driver
including:
- Check both internally and externally generated aborts to make sure the
xid is not already been aborted in another context or in cleanup.
- Check back pointers in qedf_cmd_timeout to verify the context of the
io_req, fcport and qedf_ctx
- Check rport state in host reset handler to not reset the whole host
if the rport is already uploaded or in the process of relogin
- Check to state for an fcport before initiating a middle path ELS
request
Signed-off-by: Chad Dupuis <chad.dupuis@cavium.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>