diff options
author | Linus Torvalds <torvalds@linux-foundation.org> | 2016-05-26 18:23:43 +0200 |
---|---|---|
committer | Linus Torvalds <torvalds@linux-foundation.org> | 2016-05-26 18:23:43 +0200 |
commit | bfb764440d5bee109003295473a0b387bc799222 (patch) | |
tree | 23f4683f6aca3b75d81e009f1c8f9b201a6422c1 /Documentation | |
parent | Merge branch 'for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/jmo... (diff) | |
parent | Merge branches 'thermal-core', 'thermal-intel' and 'thermal-soc' into next (diff) | |
download | linux-bfb764440d5bee109003295473a0b387bc799222.tar.xz linux-bfb764440d5bee109003295473a0b387bc799222.zip |
Merge branch 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux
Pull thermal management updates from Zhang Rui:
- Introduce generic ADC thermal driver, based on OF thermal (Laxman
Dewangan)
- Introduce new thermal driver for Tango chips (Marc Gonzalez)
- Rockchip driver support for RK3399, RK3366, and some fixes (Caesar
Wang, Elaine Zhang and Shawn Lin)
- Add CPU power cooling model to Mediatek thermal driver (Dawei Chien)
- Wider usage of dev_thermal_zone_of_sensor_register (Eduardo Valentin)
- TI thermal driver gained a new maintainer (Keerthy).
- Enabled powerclamp driver by checking CPU feature and package cstate
counter instead of CPU whitelist (Jacob Pan)
- Various fixes on thermal governor, OF thermal, Tegra, and RCAR
* 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux: (50 commits)
thermal: tango: initialize TEMPSI_CFG
thermal: rockchip: use the usleep_range instead of udelay
thermal: rockchip: add the notes for better reading
thermal: rockchip: Support RK3366 SoCs in the thermal driver
thermal: rockchip: handle the power sequence for tsadc controller
thermal: rockchip: update the tsadc table for rk3399
thermal: rockchip: fixes the code_to_temp for tsadc driver
thermal: rockchip: disable thermal->clk in err case
thermal: tegra: add Tegra132 specific SOC_THERM driver
thermal: fix ptr_ret.cocci warnings
thermal: mediatek: Add cpu dynamic power cooling model.
thermal: generic-adc: Add ADC based thermal sensor driver
thermal: generic-adc: Add DT binding for ADC based thermal sensor
thermal: tegra: fix static checker warning
thermal: tegra: mark PM functions __maybe_unused
thermal: add temperature sensor support for tango SoC
thermal: hisilicon: fix IRQ imbalance enabling
thermal: hisilicon: support to use any sensor
thermal: rcar: Remove binding docs for r8a7794
thermal: tegra: add PM support
...
Diffstat (limited to 'Documentation')
5 files changed, 140 insertions, 23 deletions
diff --git a/Documentation/devicetree/bindings/thermal/nvidia,tegra124-soctherm.txt b/Documentation/devicetree/bindings/thermal/nvidia,tegra124-soctherm.txt index 6908d3aca598..edebfa0a985e 100644 --- a/Documentation/devicetree/bindings/thermal/nvidia,tegra124-soctherm.txt +++ b/Documentation/devicetree/bindings/thermal/nvidia,tegra124-soctherm.txt @@ -26,6 +26,10 @@ Required properties : of this property. See <dt-bindings/thermal/tegra124-soctherm.h> for a list of valid values when referring to thermal sensors. +Note: +- the "critical" type trip points will be set to SOC_THERM hardware as the +shut down temperature. Once the temperature of this thermal zone is higher +than it, the system will be shutdown or reset by hardware. Example : @@ -51,5 +55,13 @@ Example: referring to thermal sensors : thermal-sensors = <&soctherm TEGRA124_SOCTHERM_SENSOR_CPU>; + + trips { + cpu_shutdown_trip: shutdown-trip { + temperature = <102500>; + hysteresis = <1000>; + type = "critical"; + }; + }; }; }; diff --git a/Documentation/devicetree/bindings/thermal/rcar-thermal.txt b/Documentation/devicetree/bindings/thermal/rcar-thermal.txt index e5ee3f159893..a8e52c8ccfcc 100644 --- a/Documentation/devicetree/bindings/thermal/rcar-thermal.txt +++ b/Documentation/devicetree/bindings/thermal/rcar-thermal.txt @@ -11,7 +11,6 @@ Required properties: - "renesas,thermal-r8a7791" (R-Car M2-W) - "renesas,thermal-r8a7792" (R-Car V2H) - "renesas,thermal-r8a7793" (R-Car M2-N) - - "renesas,thermal-r8a7794" (R-Car E2) - reg : Address range of the thermal registers. The 1st reg will be recognized as common register if it has "interrupts". diff --git a/Documentation/devicetree/bindings/thermal/tango-thermal.txt b/Documentation/devicetree/bindings/thermal/tango-thermal.txt new file mode 100644 index 000000000000..212198d4b937 --- /dev/null +++ b/Documentation/devicetree/bindings/thermal/tango-thermal.txt @@ -0,0 +1,17 @@ +* Tango Thermal + +The SMP8758 SoC includes 3 instances of this temperature sensor +(in the CPU, video decoder, and PCIe controller). + +Required properties: +- #thermal-sensor-cells: Should be 0 (see thermal.txt) +- compatible: "sigma,smp8758-thermal" +- reg: Address range of the thermal registers + +Example: + + cpu_temp: thermal@920100 { + #thermal-sensor-cells = <0>; + compatible = "sigma,smp8758-thermal"; + reg = <0x920100 12>; + }; diff --git a/Documentation/devicetree/bindings/thermal/thermal-generic-adc.txt b/Documentation/devicetree/bindings/thermal/thermal-generic-adc.txt new file mode 100644 index 000000000000..d72355502b78 --- /dev/null +++ b/Documentation/devicetree/bindings/thermal/thermal-generic-adc.txt @@ -0,0 +1,89 @@ +General Purpose Analog To Digital Converter (ADC) based thermal sensor. + +On some of platforms, thermal sensor like thermistors are connected to +one of ADC channel and sensor resistance is read via voltage across the +sensor resistor. The voltage read across the sensor is mapped to +temperature using voltage-temperature lookup table. + +Required properties: +=================== +- compatible: Must be "generic-adc-thermal". +- temperature-lookup-table: Two dimensional array of Integer; lookup table + to map the relation between ADC value and + temperature. When ADC is read, the value is + looked up on the table to get the equivalent + temperature. + The first value of the each row of array is the + temperature in milliCelsius and second value of + the each row of array is the ADC read value. +- #thermal-sensor-cells: Should be 1. See ./thermal.txt for a description + of this property. + +Example : +#include <dt-bindings/thermal/thermal.h> + +i2c@7000c400 { + ads1015: ads1015@4a { + reg = <0x4a>; + compatible = "ads1015"; + sampling-frequency = <3300>; + #io-channel-cells = <1>; + }; +}; + +tboard_thermistor: thermal-sensor { + compatible = "generic-adc-thermal"; + #thermal-sensor-cells = <0>; + io-channels = <&ads1015 1>; + io-channel-names = "sensor-channel"; + temperature-lookup-table = < (-40000) 2578 + (-39000) 2577 + (-38000) 2576 + (-37000) 2575 + (-36000) 2574 + (-35000) 2573 + (-34000) 2572 + (-33000) 2571 + (-32000) 2569 + (-31000) 2568 + (-30000) 2567 + :::::::::: + 118000 254 + 119000 247 + 120000 240 + 121000 233 + 122000 226 + 123000 220 + 124000 214 + 125000 208>; +}; + +dummy_cool_dev: dummy-cool-dev { + compatible = "dummy-cooling-dev"; + #cooling-cells = <2>; /* min followed by max */ +}; + +thermal-zones { + Tboard { + polling-delay = <15000>; /* milliseconds */ + polling-delay-passive = <0>; /* milliseconds */ + thermal-sensors = <&tboard_thermistor>; + + trips { + therm_est_trip: therm_est_trip { + temperature = <40000>; + type = "active"; + hysteresis = <1000>; + }; + }; + + cooling-maps { + map0 { + trip = <&therm_est_trip>; + cooling-device = <&dummy_cool_dev THERMAL_NO_LIMIT THERMAL_NO_LIMIT>; + contribution = <100>; + }; + + }; + }; +}; diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt index ed419d6c8dec..efc3f3d293c4 100644 --- a/Documentation/thermal/sysfs-api.txt +++ b/Documentation/thermal/sysfs-api.txt @@ -69,8 +69,8 @@ temperature) and throttle appropriate devices. 1.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz) This interface function removes the thermal zone device. - It deletes the corresponding entry form /sys/class/thermal folder and - unbind all the thermal cooling devices it uses. + It deletes the corresponding entry from /sys/class/thermal folder and + unbinds all the thermal cooling devices it uses. 1.1.3 struct thermal_zone_device *thermal_zone_of_sensor_register( struct device *dev, int sensor_id, void *data, @@ -146,32 +146,32 @@ temperature) and throttle appropriate devices. This interface function adds a new thermal cooling device (fan/processor/...) to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself - to all the thermal zone devices register at the same time. + to all the thermal zone devices registered at the same time. name: the cooling device name. devdata: device private data. ops: thermal cooling devices call-backs. .get_max_state: get the Maximum throttle state of the cooling device. - .get_cur_state: get the Current throttle state of the cooling device. + .get_cur_state: get the Currently requested throttle state of the cooling device. .set_cur_state: set the Current throttle state of the cooling device. 1.2.2 void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev) - This interface function remove the thermal cooling device. - It deletes the corresponding entry form /sys/class/thermal folder and - unbind itself from all the thermal zone devices using it. + This interface function removes the thermal cooling device. + It deletes the corresponding entry from /sys/class/thermal folder and + unbinds itself from all the thermal zone devices using it. 1.3 interface for binding a thermal zone device with a thermal cooling device 1.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz, int trip, struct thermal_cooling_device *cdev, unsigned long upper, unsigned long lower, unsigned int weight); - This interface function bind a thermal cooling device to the certain trip + This interface function binds a thermal cooling device to a particular trip point of a thermal zone device. This function is usually called in the thermal zone device .bind callback. tz: the thermal zone device cdev: thermal cooling device - trip: indicates which trip point the cooling devices is associated with - in this thermal zone. + trip: indicates which trip point in this thermal zone the cooling device + is associated with. upper:the Maximum cooling state for this trip point. THERMAL_NO_LIMIT means no upper limit, and the cooling device can be in max_state. @@ -184,13 +184,13 @@ temperature) and throttle appropriate devices. 1.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz, int trip, struct thermal_cooling_device *cdev); - This interface function unbind a thermal cooling device from the certain + This interface function unbinds a thermal cooling device from a particular trip point of a thermal zone device. This function is usually called in the thermal zone device .unbind callback. tz: the thermal zone device cdev: thermal cooling device - trip: indicates which trip point the cooling devices is associated with - in this thermal zone. + trip: indicates which trip point in this thermal zone the cooling device + is associated with. 1.4 Thermal Zone Parameters 1.4.1 struct thermal_bind_params @@ -210,13 +210,13 @@ temperature) and throttle appropriate devices. this thermal zone and cdev, for a particular trip point. If nth bit is set, then the cdev and thermal zone are bound for trip point n. - .limits: This is an array of cooling state limits. Must have exactly - 2 * thermal_zone.number_of_trip_points. It is an array consisting - of tuples <lower-state upper-state> of state limits. Each trip - will be associated with one state limit tuple when binding. - A NULL pointer means <THERMAL_NO_LIMITS THERMAL_NO_LIMITS> - on all trips. These limits are used when binding a cdev to a - trip point. + .binding_limits: This is an array of cooling state limits. Must have + exactly 2 * thermal_zone.number_of_trip_points. It is an + array consisting of tuples <lower-state upper-state> of + state limits. Each trip will be associated with one state + limit tuple when binding. A NULL pointer means + <THERMAL_NO_LIMITS THERMAL_NO_LIMITS> on all trips. + These limits are used when binding a cdev to a trip point. .match: This call back returns success(0) if the 'tz and cdev' need to be bound, as per platform data. 1.4.2 struct thermal_zone_params @@ -351,8 +351,8 @@ cdev[0-*] RO, Optional cdev[0-*]_trip_point - The trip point with which cdev[0-*] is associated in this thermal - zone; -1 means the cooling device is not associated with any trip + The trip point in this thermal zone which cdev[0-*] is associated + with; -1 means the cooling device is not associated with any trip point. RO, Optional |