diff options
author | Geert Uytterhoeven <geert+renesas@linux-m68k.org> | 2014-03-13 15:29:30 +0100 |
---|---|---|
committer | Simon Horman <horms+renesas@verge.net.au> | 2014-04-14 04:30:39 +0200 |
commit | 53cf0cf7ba2ef785b339826a0765bb6b1756adeb (patch) | |
tree | 035e9c2eee5bef0f1fb91bcd820c82125104daae /arch/arm/mach-shmobile/board-koelsch-reference.c | |
parent | ARM: shmobile: lager: Annotate clk_names with __initconst (diff) | |
download | linux-53cf0cf7ba2ef785b339826a0765bb6b1756adeb.tar.xz linux-53cf0cf7ba2ef785b339826a0765bb6b1756adeb.zip |
ARM: shmobile: koelsch-reference: Work around core clock issues
Due to issues with runtime PM clock management, clocks not explicitly
managed by their drivers may not be enabled at all, or be inadvertently
disabled by the clk_disable_unused() late initcall.
Until this is fixed, add a temporary workaround, calling
shmobile_clk_workaround() with enable == true.
For now this enables the clocks for: ether, i2c2, msiof0, qspi_mod, and
thermal. More clocks can be added if needed.
Signed-off-by: Geert Uytterhoeven <geert+renesas@linux-m68k.org>
Signed-off-by: Simon Horman <horms+renesas@verge.net.au>
Diffstat (limited to 'arch/arm/mach-shmobile/board-koelsch-reference.c')
-rw-r--r-- | arch/arm/mach-shmobile/board-koelsch-reference.c | 12 |
1 files changed, 12 insertions, 0 deletions
diff --git a/arch/arm/mach-shmobile/board-koelsch-reference.c b/arch/arm/mach-shmobile/board-koelsch-reference.c index 1e6a4361c0eb..a39114a1fe1b 100644 --- a/arch/arm/mach-shmobile/board-koelsch-reference.c +++ b/arch/arm/mach-shmobile/board-koelsch-reference.c @@ -107,9 +107,21 @@ static const struct clk_name clk_names[] __initconst = { { "lvds0", "lvds.0", "rcar-du-r8a7791" }, }; +/* + * This is a really crude hack to work around core platform clock issues + */ +static const struct clk_name clk_enables[] = { + { "ether", NULL, "ee700000.ethernet" }, + { "i2c2", NULL, "e6530000.i2c" }, + { "msiof0", NULL, "e6e20000.spi" }, + { "qspi_mod", NULL, "e6b10000.spi" }, + { "thermal", NULL, "e61f0000.thermal" }, +}; + static void __init koelsch_add_standard_devices(void) { shmobile_clk_workaround(clk_names, ARRAY_SIZE(clk_names), false); + shmobile_clk_workaround(clk_enables, ARRAY_SIZE(clk_enables), true); r8a7791_add_dt_devices(); of_platform_populate(NULL, of_default_bus_match_table, NULL, NULL); |