diff options
author | Sergio Paracuellos <sergio.paracuellos@gmail.com> | 2023-08-27 04:39:32 +0200 |
---|---|---|
committer | Stephen Boyd <sboyd@kernel.org> | 2023-10-19 02:31:44 +0200 |
commit | 619102313466eaf8a6ac188e711f5df749dac6d4 (patch) | |
tree | 24eb0f7de56583c12fec8016044183a2cdc9b168 /drivers/clk | |
parent | clk: gate: fix comment typo and grammar (diff) | |
download | linux-619102313466eaf8a6ac188e711f5df749dac6d4.tar.xz linux-619102313466eaf8a6ac188e711f5df749dac6d4.zip |
clk: ralink: mtmips: quiet unused variable warning
When CONFIG_OF is disabled then the matching table is not referenced and
the following warning appears:
drivers/clk/ralink/clk-mtmips.c:821:34: warning: unused variable 'mtmips_of_match' [-Wunused-const-variable]
821 | static const struct of_device_id mtmips_of_match[] = {
| ^
There are two match tables in the driver: one for the clock driver and the
other for the reset driver. The only difference between them is that the
clock driver uses 'data' and does not have 'ralink,rt2880-reset' compatible.
Both just can be merged into a single one just by adding the compatible
'ralink,rt2880-reset' entry to 'mtmips_of_match[]', which will allow it to
be used for 'mtmips_clk_driver' (which doesn't use the data) as well as for
'mtmips_clk_init()' (which doesn't need get called for 'ralink,rt2880-reset').
Doing in this way ensures that 'CONFIG_OF' is not disabled anymore so the
above warning disapears.
Fixes: 6f3b15586eef ("clk: ralink: add clock and reset driver for MTMIPS SoCs")
Reported-by: kernel test robot <lkp@intel.com>
Closes: https://lore.kernel.org/oe-kbuild-all/202307242310.CdOnd2py-lkp@intel.com/
Suggested-by: Arnd Bergmann <arnd@kernel.org>
Signed-off-by: Sergio Paracuellos <sergio.paracuellos@gmail.com>
Link: https://lore.kernel.org/r/20230827023932.501102-1-sergio.paracuellos@gmail.com
Reviewed-by: Nathan Chancellor <nathan@kernel.org>
Signed-off-by: Stephen Boyd <sboyd@kernel.org>
Diffstat (limited to 'drivers/clk')
-rw-r--r-- | drivers/clk/ralink/clk-mtmips.c | 20 |
1 files changed, 5 insertions, 15 deletions
diff --git a/drivers/clk/ralink/clk-mtmips.c b/drivers/clk/ralink/clk-mtmips.c index 1e7991439527..50a443bf79ec 100644 --- a/drivers/clk/ralink/clk-mtmips.c +++ b/drivers/clk/ralink/clk-mtmips.c @@ -822,6 +822,10 @@ static const struct mtmips_clk_data mt76x8_clk_data = { static const struct of_device_id mtmips_of_match[] = { { + .compatible = "ralink,rt2880-reset", + .data = NULL, + }, + { .compatible = "ralink,rt2880-sysc", .data = &rt2880_clk_data, }, @@ -1088,25 +1092,11 @@ static int mtmips_clk_probe(struct platform_device *pdev) return 0; } -static const struct of_device_id mtmips_clk_of_match[] = { - { .compatible = "ralink,rt2880-reset" }, - { .compatible = "ralink,rt2880-sysc" }, - { .compatible = "ralink,rt3050-sysc" }, - { .compatible = "ralink,rt3052-sysc" }, - { .compatible = "ralink,rt3352-sysc" }, - { .compatible = "ralink,rt3883-sysc" }, - { .compatible = "ralink,rt5350-sysc" }, - { .compatible = "ralink,mt7620-sysc" }, - { .compatible = "ralink,mt7628-sysc" }, - { .compatible = "ralink,mt7688-sysc" }, - {} -}; - static struct platform_driver mtmips_clk_driver = { .probe = mtmips_clk_probe, .driver = { .name = "mtmips-clk", - .of_match_table = mtmips_clk_of_match, + .of_match_table = mtmips_of_match, }, }; |