diff options
author | Linus Torvalds <torvalds@linux-foundation.org> | 2017-07-14 22:12:32 +0200 |
---|---|---|
committer | Linus Torvalds <torvalds@linux-foundation.org> | 2017-07-14 22:12:32 +0200 |
commit | 4d25ec19669292a65a32498eabdabdd32b1a8747 (patch) | |
tree | c05bcadf3c4f24dedac48a3256add87a5af7655e /drivers/cpufreq | |
parent | Merge tag 'mmc-v4.13-2' of git://git.kernel.org/pub/scm/linux/kernel/git/ulfh... (diff) | |
parent | Merge branches 'thermal-core', 'thermal-intel' and 'thermal-soc' into next (diff) | |
download | linux-4d25ec19669292a65a32498eabdabdd32b1a8747.tar.xz linux-4d25ec19669292a65a32498eabdabdd32b1a8747.zip |
Merge branch 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux
Pull thermal management updates from Zhang Rui:
- Improve thermal cpu_cooling interaction with cpufreq core.
The cpu_cooling driver is designed to use CPU frequency scaling to
avoid high thermal states for a platform. But it wasn't glued really
well with cpufreq core.
For example clipped-cpus is copied from the policy structure and its
much better to use the policy->cpus (or related_cpus) fields directly
as they may have got updated. Not that things were broken before this
series, but they can be optimized a bit more.
This series tries to improve interactions between cpufreq core and
cpu_cooling driver and does some fixes/cleanups to the cpu_cooling
driver. (Viresh Kumar)
- A couple of fixes and cleanups in thermal core and imx, hisilicon,
bcm_2835, int340x thermal drivers. (Arvind Yadav, Dan Carpenter,
Sumeet Pawnikar, Srinivas Pandruvada, Willy WOLFF)
* 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux: (24 commits)
thermal: bcm2835: fix an error code in probe()
thermal: hisilicon: Handle return value of clk_prepare_enable
thermal: imx: Handle return value of clk_prepare_enable
thermal: int340x: check for sensor when PTYP is missing
Thermal/int340x: Fix few typos and kernel-doc style
thermal: fix source code documentation for parameters
thermal: cpu_cooling: Replace kmalloc with kmalloc_array
thermal: cpu_cooling: Rearrange struct cpufreq_cooling_device
thermal: cpu_cooling: 'freq' can't be zero in cpufreq_state2power()
thermal: cpu_cooling: don't store cpu_dev in cpufreq_cdev
thermal: cpu_cooling: get_level() can't fail
thermal: cpu_cooling: create structure for idle time stats
thermal: cpu_cooling: merge frequency and power tables
thermal: cpu_cooling: get rid of 'allowed_cpus'
thermal: cpu_cooling: OPPs are registered for all CPUs
thermal: cpu_cooling: store cpufreq policy
cpufreq: create cpufreq_table_count_valid_entries()
thermal: cpu_cooling: use cpufreq_policy to register cooling device
thermal: cpu_cooling: get rid of a variable in cpufreq_set_cur_state()
thermal: cpu_cooling: remove cpufreq_cooling_get_level()
...
Diffstat (limited to 'drivers/cpufreq')
-rw-r--r-- | drivers/cpufreq/arm_big_little.c | 2 | ||||
-rw-r--r-- | drivers/cpufreq/cpufreq-dt.c | 2 | ||||
-rw-r--r-- | drivers/cpufreq/cpufreq_stats.c | 13 | ||||
-rw-r--r-- | drivers/cpufreq/dbx500-cpufreq.c | 2 | ||||
-rw-r--r-- | drivers/cpufreq/mt8173-cpufreq.c | 4 | ||||
-rw-r--r-- | drivers/cpufreq/qoriq-cpufreq.c | 3 |
6 files changed, 9 insertions, 17 deletions
diff --git a/drivers/cpufreq/arm_big_little.c b/drivers/cpufreq/arm_big_little.c index 418042201e6d..ea6d62547b10 100644 --- a/drivers/cpufreq/arm_big_little.c +++ b/drivers/cpufreq/arm_big_little.c @@ -540,7 +540,7 @@ static void bL_cpufreq_ready(struct cpufreq_policy *policy) &power_coefficient); cdev[cur_cluster] = of_cpufreq_power_cooling_register(np, - policy->related_cpus, power_coefficient, NULL); + policy, power_coefficient, NULL); if (IS_ERR(cdev[cur_cluster])) { dev_err(cpu_dev, "running cpufreq without cooling device: %ld\n", diff --git a/drivers/cpufreq/cpufreq-dt.c b/drivers/cpufreq/cpufreq-dt.c index c943787d761e..fef3c2160691 100644 --- a/drivers/cpufreq/cpufreq-dt.c +++ b/drivers/cpufreq/cpufreq-dt.c @@ -326,7 +326,7 @@ static void cpufreq_ready(struct cpufreq_policy *policy) &power_coefficient); priv->cdev = of_cpufreq_power_cooling_register(np, - policy->related_cpus, power_coefficient, NULL); + policy, power_coefficient, NULL); if (IS_ERR(priv->cdev)) { dev_err(priv->cpu_dev, "running cpufreq without cooling device: %ld\n", diff --git a/drivers/cpufreq/cpufreq_stats.c b/drivers/cpufreq/cpufreq_stats.c index d362739a71f3..e75880eb037d 100644 --- a/drivers/cpufreq/cpufreq_stats.c +++ b/drivers/cpufreq/cpufreq_stats.c @@ -170,11 +170,10 @@ void cpufreq_stats_create_table(struct cpufreq_policy *policy) unsigned int i = 0, count = 0, ret = -ENOMEM; struct cpufreq_stats *stats; unsigned int alloc_size; - struct cpufreq_frequency_table *pos, *table; + struct cpufreq_frequency_table *pos; - /* We need cpufreq table for creating stats table */ - table = policy->freq_table; - if (unlikely(!table)) + count = cpufreq_table_count_valid_entries(policy); + if (!count) return; /* stats already initialized */ @@ -185,10 +184,6 @@ void cpufreq_stats_create_table(struct cpufreq_policy *policy) if (!stats) return; - /* Find total allocation size */ - cpufreq_for_each_valid_entry(pos, table) - count++; - alloc_size = count * sizeof(int) + count * sizeof(u64); alloc_size += count * count * sizeof(int); @@ -205,7 +200,7 @@ void cpufreq_stats_create_table(struct cpufreq_policy *policy) stats->max_state = count; /* Find valid-unique entries */ - cpufreq_for_each_valid_entry(pos, table) + cpufreq_for_each_valid_entry(pos, policy->freq_table) if (freq_table_get_index(stats, pos->frequency) == -1) stats->freq_table[i++] = pos->frequency; diff --git a/drivers/cpufreq/dbx500-cpufreq.c b/drivers/cpufreq/dbx500-cpufreq.c index 3575b82210ba..4ee0431579c1 100644 --- a/drivers/cpufreq/dbx500-cpufreq.c +++ b/drivers/cpufreq/dbx500-cpufreq.c @@ -43,7 +43,7 @@ static int dbx500_cpufreq_exit(struct cpufreq_policy *policy) static void dbx500_cpufreq_ready(struct cpufreq_policy *policy) { - cdev = cpufreq_cooling_register(policy->cpus); + cdev = cpufreq_cooling_register(policy); if (IS_ERR(cdev)) pr_err("Failed to register cooling device %ld\n", PTR_ERR(cdev)); else diff --git a/drivers/cpufreq/mt8173-cpufreq.c b/drivers/cpufreq/mt8173-cpufreq.c index fd1886faf33a..f9f00fb4bc3a 100644 --- a/drivers/cpufreq/mt8173-cpufreq.c +++ b/drivers/cpufreq/mt8173-cpufreq.c @@ -320,9 +320,7 @@ static void mtk_cpufreq_ready(struct cpufreq_policy *policy) of_property_read_u32(np, DYNAMIC_POWER, &capacitance); info->cdev = of_cpufreq_power_cooling_register(np, - policy->related_cpus, - capacitance, - NULL); + policy, capacitance, NULL); if (IS_ERR(info->cdev)) { dev_err(info->cpu_dev, diff --git a/drivers/cpufreq/qoriq-cpufreq.c b/drivers/cpufreq/qoriq-cpufreq.c index e2ea433a5f9c..4ada55b8856e 100644 --- a/drivers/cpufreq/qoriq-cpufreq.c +++ b/drivers/cpufreq/qoriq-cpufreq.c @@ -278,8 +278,7 @@ static void qoriq_cpufreq_ready(struct cpufreq_policy *policy) struct device_node *np = of_get_cpu_node(policy->cpu, NULL); if (of_find_property(np, "#cooling-cells", NULL)) { - cpud->cdev = of_cpufreq_cooling_register(np, - policy->related_cpus); + cpud->cdev = of_cpufreq_cooling_register(np, policy); if (IS_ERR(cpud->cdev) && PTR_ERR(cpud->cdev) != -ENOSYS) { pr_err("cpu%d is not running as cooling device: %ld\n", |