diff options
author | Dmitry Torokhov <dmitry.torokhov@gmail.com> | 2018-07-13 16:13:52 +0200 |
---|---|---|
committer | Jiri Kosina <jkosina@suse.cz> | 2018-07-17 15:33:47 +0200 |
commit | 9152c7d77d87e2b6b9ccc21bb52f8eea15744f50 (patch) | |
tree | e0a8982cdfac38df1fc87796179e37278766de8b /drivers/hid | |
parent | HID: microsoft: support the Surface Dial (diff) | |
download | linux-9152c7d77d87e2b6b9ccc21bb52f8eea15744f50.tar.xz linux-9152c7d77d87e2b6b9ccc21bb52f8eea15744f50.zip |
HID: multitouch: report MT_TOOL_PALM for non-confident touches
According to Microsoft specification [1] for Precision Touchpads (and
Touchscreens) the devices use "confidence" reports to signal accidental
touches, or contacts that are "too large to be a finger". Instead of
simply marking contact inactive in this case (which causes issues if
contact was originally proper and we lost confidence in it later, as
this results in accidental clicks, drags, etc), let's report such
contacts as MT_TOOL_PALM and let userspace decide what to do.
[1] https://docs.microsoft.com/en-us/windows-hardware/design/component-guidelines/touchpad-windows-precision-touchpad-collection
Signed-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>
[splitted and rebased]
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Diffstat (limited to 'drivers/hid')
-rw-r--r-- | drivers/hid/hid-multitouch.c | 19 |
1 files changed, 14 insertions, 5 deletions
diff --git a/drivers/hid/hid-multitouch.c b/drivers/hid/hid-multitouch.c index a4a274ebfbef..587369443f50 100644 --- a/drivers/hid/hid-multitouch.c +++ b/drivers/hid/hid-multitouch.c @@ -736,6 +736,13 @@ static int mt_touch_input_mapping(struct hid_device *hdev, struct hid_input *hi, cls->name == MT_CLS_WIN_8_DUAL) && field->application == HID_DG_TOUCHPAD) app->quirks |= MT_QUIRK_CONFIDENCE; + + if (app->quirks & MT_QUIRK_CONFIDENCE) + input_set_abs_params(hi->input, + ABS_MT_TOOL_TYPE, + MT_TOOL_FINGER, + MT_TOOL_PALM, 0, 0); + MT_STORE_FIELD(confidence_state); return 1; case HID_DG_TIPSWITCH: @@ -958,10 +965,12 @@ static int mt_process_slot(struct mt_device *td, struct input_dev *input, if (quirks & MT_QUIRK_HOVERING) inrange_state = *slot->inrange_state; - active = (*slot->tip_state || inrange_state) && confidence_state; + active = *slot->tip_state || inrange_state; if (app->application == HID_GD_SYSTEM_MULTIAXIS) tool = MT_TOOL_DIAL; + else if (unlikely(!confidence_state)) + tool = MT_TOOL_PALM; input_mt_slot(input, slotnum); input_mt_report_slot_state(input, tool, active); @@ -993,11 +1002,11 @@ static int mt_process_slot(struct mt_device *td, struct input_dev *input, orientation = -azimuth; } - /* - * divided by two to match visual scale of touch - * for devices with this quirk - */ if (quirks & MT_QUIRK_TOUCH_SIZE_SCALING) { + /* + * divided by two to match visual scale of touch + * for devices with this quirk + */ major = major >> 1; minor = minor >> 1; } |