diff options
author | Guenter Roeck <guenter.roeck@ericsson.com> | 2011-03-09 08:00:10 +0100 |
---|---|---|
committer | Guenter Roeck <guenter.roeck@ericsson.com> | 2011-05-19 17:19:38 +0200 |
commit | 2cfa6aedb32c9c1226094ed383dc3c9b3e2ecddb (patch) | |
tree | 75f7a7d3c90d8416370300f5bec2ee45bcc2b44b /drivers/hwmon/max34440.c | |
parent | hwmon: (pmbus) Introduce infrastructure to detect sensors and limit registers (diff) | |
download | linux-2cfa6aedb32c9c1226094ed383dc3c9b3e2ecddb.tar.xz linux-2cfa6aedb32c9c1226094ed383dc3c9b3e2ecddb.zip |
hwmon: (pmbus) Expand scope of device specific get_status function
Some devices use non-standard registers to access various functionality.
This does not only affect status registers, but other registers as well.
Rename local get_status function to get_byte_data to reflect this requirement.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Tom Grennan <tom.grennan@ericsson.com>
Diffstat (limited to 'drivers/hwmon/max34440.c')
-rw-r--r-- | drivers/hwmon/max34440.c | 6 |
1 files changed, 3 insertions, 3 deletions
diff --git a/drivers/hwmon/max34440.c b/drivers/hwmon/max34440.c index 992b701b4c5e..db11e1a175b2 100644 --- a/drivers/hwmon/max34440.c +++ b/drivers/hwmon/max34440.c @@ -32,7 +32,7 @@ enum chips { max34440, max34441 }; #define MAX34440_STATUS_OT_FAULT (1 << 5) #define MAX34440_STATUS_OT_WARN (1 << 6) -static int max34440_get_status(struct i2c_client *client, int page, int reg) +static int max34440_read_byte_data(struct i2c_client *client, int page, int reg) { int ret; int mfg_status; @@ -108,7 +108,7 @@ static struct pmbus_driver_info max34440_info[] = { .func[11] = PMBUS_HAVE_TEMP | PMBUS_HAVE_STATUS_TEMP, .func[12] = PMBUS_HAVE_TEMP | PMBUS_HAVE_STATUS_TEMP, .func[13] = PMBUS_HAVE_TEMP | PMBUS_HAVE_STATUS_TEMP, - .get_status = max34440_get_status, + .read_byte_data = max34440_read_byte_data, }, [max34441] = { .pages = 12, @@ -149,7 +149,7 @@ static struct pmbus_driver_info max34440_info[] = { .func[9] = PMBUS_HAVE_TEMP | PMBUS_HAVE_STATUS_TEMP, .func[10] = PMBUS_HAVE_TEMP | PMBUS_HAVE_STATUS_TEMP, .func[11] = PMBUS_HAVE_TEMP | PMBUS_HAVE_STATUS_TEMP, - .get_status = max34440_get_status, + .read_byte_data = max34440_read_byte_data, }, }; |