iio: adc: Add support for PMIC7 ADC
The ADC architecture on PMIC7 is changed as compared to PMIC5. The
major change from PMIC5 is that all SW communication to ADC goes through
PMK8350, which communicates with other PMICs through PBS when the ADC
on PMK8350 works in master mode. The SID register is used to identify the
PMICs with which the PBS needs to communicate. Add support for the same.
Signed-off-by: Jishnu Prakash <jprakash@codeaurora.org>
Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Diffstat (limited to 'drivers/iio/adc/qcom-vadc-common.h')
-rw-r--r-- | drivers/iio/adc/qcom-vadc-common.h | 14 |
1 files changed, 14 insertions, 0 deletions
diff --git a/drivers/iio/adc/qcom-vadc-common.h b/drivers/iio/adc/qcom-vadc-common.h index 6a7553fe3642..17b2fc4d8bf2 100644 --- a/drivers/iio/adc/qcom-vadc-common.h +++ b/drivers/iio/adc/qcom-vadc-common.h @@ -49,6 +49,14 @@ #define ADC5_FULL_SCALE_CODE 0x70e4 #define ADC5_USR_DATA_CHECK 0x8000 +#define R_PU_100K 100000 +#define RATIO_MAX_ADC7 BIT(14) + +#define DIE_TEMP_ADC7_SCALE_1 -60000 +#define DIE_TEMP_ADC7_SCALE_2 20000 +#define DIE_TEMP_ADC7_SCALE_FACTOR 1000 +#define DIE_TEMP_ADC7_MAX 160000 + /** * struct vadc_map_pt - Map the graph representation for ADC channel * @x: Represent the ADC digitized code. @@ -110,8 +118,12 @@ struct vadc_prescale_ratio { * lookup table. The hardware applies offset/slope to adc code. * SCALE_HW_CALIB_XOTHERM: Returns XO thermistor voltage in millidegC using * 100k pullup. The hardware applies offset/slope to adc code. + * SCALE_HW_CALIB_THERM_100K_PU_PM7: Returns temperature in millidegC using + * lookup table for PMIC7. The hardware applies offset/slope to adc code. * SCALE_HW_CALIB_PMIC_THERM: Returns result in milli degree's Centigrade. * The hardware applies offset/slope to adc code. + * SCALE_HW_CALIB_PMIC_THERM: Returns result in milli degree's Centigrade. + * The hardware applies offset/slope to adc code. This is for PMIC7. * SCALE_HW_CALIB_PM5_CHG_TEMP: Returns result in millidegrees for PMIC5 * charger temperature. * SCALE_HW_CALIB_PM5_SMB_TEMP: Returns result in millidegrees for PMIC5 @@ -126,7 +138,9 @@ enum vadc_scale_fn_type { SCALE_HW_CALIB_DEFAULT, SCALE_HW_CALIB_THERM_100K_PULLUP, SCALE_HW_CALIB_XOTHERM, + SCALE_HW_CALIB_THERM_100K_PU_PM7, SCALE_HW_CALIB_PMIC_THERM, + SCALE_HW_CALIB_PMIC_THERM_PM7, SCALE_HW_CALIB_PM5_CHG_TEMP, SCALE_HW_CALIB_PM5_SMB_TEMP, SCALE_HW_CALIB_INVALID, |