summaryrefslogtreecommitdiffstats
path: root/drivers/iio/humidity
diff options
context:
space:
mode:
authorGreg Kroah-Hartman <gregkh@linuxfoundation.org>2016-06-20 17:25:44 +0200
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>2016-06-20 17:25:44 +0200
commitaf52739b922f656eb1f39016fabaabe4baeda2e2 (patch)
tree79a7aa810d0493cd0cf4adebac26d37f12e8b545 /drivers/iio/humidity
parentstaging/lustre: Update FID documentation link. (diff)
parentLinux 4.7-rc4 (diff)
downloadlinux-af52739b922f656eb1f39016fabaabe4baeda2e2.tar.xz
linux-af52739b922f656eb1f39016fabaabe4baeda2e2.zip
Merge 4.7-rc4 into staging-next
We want the fixes in here, and we can resolve a merge issue in drivers/iio/industrialio-trigger.c Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Diffstat (limited to 'drivers/iio/humidity')
-rw-r--r--drivers/iio/humidity/am2315.c4
-rw-r--r--drivers/iio/humidity/hdc100x.c20
2 files changed, 11 insertions, 13 deletions
diff --git a/drivers/iio/humidity/am2315.c b/drivers/iio/humidity/am2315.c
index 8de39bd349f9..3e200f69e886 100644
--- a/drivers/iio/humidity/am2315.c
+++ b/drivers/iio/humidity/am2315.c
@@ -165,10 +165,8 @@ static irqreturn_t am2315_trigger_handler(int irq, void *p)
struct am2315_sensor_data sensor_data;
ret = am2315_read_data(data, &sensor_data);
- if (ret < 0) {
- mutex_unlock(&data->lock);
+ if (ret < 0)
goto err;
- }
mutex_lock(&data->lock);
if (*(indio_dev->active_scan_mask) == AM2315_ALL_CHANNEL_MASK) {
diff --git a/drivers/iio/humidity/hdc100x.c b/drivers/iio/humidity/hdc100x.c
index fa4767613173..a03832a5fc95 100644
--- a/drivers/iio/humidity/hdc100x.c
+++ b/drivers/iio/humidity/hdc100x.c
@@ -55,7 +55,7 @@ static const struct {
},
{ /* IIO_HUMIDITYRELATIVE channel */
.shift = 8,
- .mask = 2,
+ .mask = 3,
},
};
@@ -164,14 +164,14 @@ static int hdc100x_get_measurement(struct hdc100x_data *data,
dev_err(&client->dev, "cannot read high byte measurement");
return ret;
}
- val = ret << 6;
+ val = ret << 8;
ret = i2c_smbus_read_byte(client);
if (ret < 0) {
dev_err(&client->dev, "cannot read low byte measurement");
return ret;
}
- val |= ret >> 2;
+ val |= ret;
return val;
}
@@ -211,18 +211,18 @@ static int hdc100x_read_raw(struct iio_dev *indio_dev,
return IIO_VAL_INT_PLUS_MICRO;
case IIO_CHAN_INFO_SCALE:
if (chan->type == IIO_TEMP) {
- *val = 165;
- *val2 = 65536 >> 2;
+ *val = 165000;
+ *val2 = 65536;
return IIO_VAL_FRACTIONAL;
} else {
- *val = 0;
- *val2 = 10000;
- return IIO_VAL_INT_PLUS_MICRO;
+ *val = 100;
+ *val2 = 65536;
+ return IIO_VAL_FRACTIONAL;
}
break;
case IIO_CHAN_INFO_OFFSET:
- *val = -3971;
- *val2 = 879096;
+ *val = -15887;
+ *val2 = 515151;
return IIO_VAL_INT_PLUS_MICRO;
default:
return -EINVAL;