diff options
author | Konrad Dybcio <konrad.dybcio@linaro.org> | 2023-06-19 15:04:41 +0200 |
---|---|---|
committer | Bjorn Andersson <andersson@kernel.org> | 2023-07-15 18:54:45 +0200 |
commit | 9d0a282c3e26c59c5a90d5fb4c167fe103f53bc8 (patch) | |
tree | 5f0835bd2e1b9a48f28d41386c3ebd74dd9fe940 /drivers/interconnect | |
parent | interconnect: qcom: msm8916: Hook up RPM bus clk definitions (diff) | |
download | linux-9d0a282c3e26c59c5a90d5fb4c167fe103f53bc8.tar.xz linux-9d0a282c3e26c59c5a90d5fb4c167fe103f53bc8.zip |
interconnect: qcom: qcm2290: Hook up RPM bus clk definitions
Assign the necessary definitions to migrate to the new bus clock
handling mechanism.
Reviewed-by: Dmitry Baryshkov <dmitry.baryshkov@linaro.org>
Signed-off-by: Konrad Dybcio <konrad.dybcio@linaro.org>
Acked-by: Georgi Djakov <djakov@kernel.org>
Link: https://lore.kernel.org/r/20230526-topic-smd_icc-v7-16-09c78c175546@linaro.org
Signed-off-by: Bjorn Andersson <andersson@kernel.org>
Diffstat (limited to 'drivers/interconnect')
-rw-r--r-- | drivers/interconnect/qcom/qcm2290.c | 6 |
1 files changed, 6 insertions, 0 deletions
diff --git a/drivers/interconnect/qcom/qcm2290.c b/drivers/interconnect/qcom/qcm2290.c index 36a53add866d..8fc4acc4220b 100644 --- a/drivers/interconnect/qcom/qcm2290.c +++ b/drivers/interconnect/qcom/qcm2290.c @@ -1195,6 +1195,7 @@ static const struct qcom_icc_desc qcm2290_bimc = { .type = QCOM_ICC_BIMC, .nodes = qcm2290_bimc_nodes, .num_nodes = ARRAY_SIZE(qcm2290_bimc_nodes), + .bus_clk_desc = &bimc_clk, .regmap_cfg = &qcm2290_bimc_regmap_config, /* M_REG_BASE() in vendor msm_bus_bimc_adhoc driver */ .qos_offset = 0x8000, @@ -1250,6 +1251,7 @@ static const struct qcom_icc_desc qcm2290_cnoc = { .type = QCOM_ICC_NOC, .nodes = qcm2290_cnoc_nodes, .num_nodes = ARRAY_SIZE(qcm2290_cnoc_nodes), + .bus_clk_desc = &bus_1_clk, .regmap_cfg = &qcm2290_cnoc_regmap_config, }; @@ -1291,6 +1293,7 @@ static const struct qcom_icc_desc qcm2290_snoc = { .type = QCOM_ICC_QNOC, .nodes = qcm2290_snoc_nodes, .num_nodes = ARRAY_SIZE(qcm2290_snoc_nodes), + .bus_clk_desc = &bus_2_clk, .regmap_cfg = &qcm2290_snoc_regmap_config, /* Vendor DT node fab-sys_noc property 'qcom,base-offset' */ .qos_offset = 0x15000, @@ -1305,6 +1308,7 @@ static const struct qcom_icc_desc qcm2290_qup_virt = { .type = QCOM_ICC_QNOC, .nodes = qcm2290_qup_virt_nodes, .num_nodes = ARRAY_SIZE(qcm2290_qup_virt_nodes), + .bus_clk_desc = &qup_clk, }; static struct qcom_icc_node * const qcm2290_mmnrt_virt_nodes[] = { @@ -1318,6 +1322,7 @@ static const struct qcom_icc_desc qcm2290_mmnrt_virt = { .type = QCOM_ICC_QNOC, .nodes = qcm2290_mmnrt_virt_nodes, .num_nodes = ARRAY_SIZE(qcm2290_mmnrt_virt_nodes), + .bus_clk_desc = &mmaxi_0_clk, .regmap_cfg = &qcm2290_snoc_regmap_config, .qos_offset = 0x15000, }; @@ -1332,6 +1337,7 @@ static const struct qcom_icc_desc qcm2290_mmrt_virt = { .type = QCOM_ICC_QNOC, .nodes = qcm2290_mmrt_virt_nodes, .num_nodes = ARRAY_SIZE(qcm2290_mmrt_virt_nodes), + .bus_clk_desc = &mmaxi_1_clk, .regmap_cfg = &qcm2290_snoc_regmap_config, .qos_offset = 0x15000, }; |