summaryrefslogtreecommitdiffstats
path: root/drivers/iommu/io-pgtable-arm-v7s.c
diff options
context:
space:
mode:
authorYong Wu <yong.wu@mediatek.com>2018-03-18 02:52:54 +0100
committerJoerg Roedel <jroedel@suse.de>2018-03-21 12:13:57 +0100
commit70ca608b2ec6dafa6bb1c2b0691852fc78f8f717 (patch)
tree9e1bc273b91fefbde05e482bd7a7539ba37430a4 /drivers/iommu/io-pgtable-arm-v7s.c
parentiommu/mediatek: Move attach_device after iommu-group is ready for M4Uv1 (diff)
downloadlinux-70ca608b2ec6dafa6bb1c2b0691852fc78f8f717.tar.xz
linux-70ca608b2ec6dafa6bb1c2b0691852fc78f8f717.zip
iommu/mediatek: Fix protect memory setting
In MediaTek's IOMMU design, When a iommu translation fault occurs (HW can NOT translate the destination address to a valid physical address), the IOMMU HW output the dirty data into a special memory to avoid corrupting the main memory, this is called "protect memory". the register(0x114) for protect memory is a little different between mt8173 and mt2712. In the mt8173, bit[30:6] in the register represents [31:7] of the physical address. In the 4GB mode, the register bit[31] should be 1. While in the mt2712, the bits don't shift. bit[31:7] in the register represents [31:7] in the physical address, and bit[1:0] in the register represents bit[33:32] of the physical address if it has. Fixes: e6dec9230862 ("iommu/mediatek: Add mt2712 IOMMU support") Reported-by: Honghui Zhang <honghui.zhang@mediatek.com> Signed-off-by: Yong Wu <yong.wu@mediatek.com> Signed-off-by: Joerg Roedel <jroedel@suse.de>
Diffstat (limited to 'drivers/iommu/io-pgtable-arm-v7s.c')
0 files changed, 0 insertions, 0 deletions