diff options
author | Michael Chan <mchan@broadcom.com> | 2008-11-13 01:02:20 +0100 |
---|---|---|
committer | David S. Miller <davem@davemloft.net> | 2008-11-13 01:02:20 +0100 |
commit | d8026d939495c105cf747c0196a8fa738cf2ad20 (patch) | |
tree | 9240f3af1002c84bfdedbc4c952234684eef3a92 /drivers/net/bnx2.h | |
parent | bnx2: Restrict WoL support. (diff) | |
download | linux-d8026d939495c105cf747c0196a8fa738cf2ad20.tar.xz linux-d8026d939495c105cf747c0196a8fa738cf2ad20.zip |
bnx2: Set rx buffer water marks based on MTU.
The default rx buffer water marks for XOFF/XON are for 1500 MTU. At
larger MTUs, these water marks need to be adjusted for effective
flow control.
Signed-off-by: Michael Chan <mchan@broadcom.com>
Signed-off-by: Matt Carlson <mcarlson@broadcom.com>
Signed-off-by: Benjamin Li <benli@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to '')
-rw-r--r-- | drivers/net/bnx2.h | 21 |
1 files changed, 21 insertions, 0 deletions
diff --git a/drivers/net/bnx2.h b/drivers/net/bnx2.h index 617d95340160..2b9649ae6307 100644 --- a/drivers/net/bnx2.h +++ b/drivers/net/bnx2.h @@ -4199,7 +4199,14 @@ struct l2_fhdr { #define BNX2_RBUF_CONFIG 0x0020000c #define BNX2_RBUF_CONFIG_XOFF_TRIP (0x3ffL<<0) +#define BNX2_RBUF_CONFIG_XOFF_TRIP_VAL(mtu) \ + ((((mtu) - 1500) * 31 / 1000) + 54) #define BNX2_RBUF_CONFIG_XON_TRIP (0x3ffL<<16) +#define BNX2_RBUF_CONFIG_XON_TRIP_VAL(mtu) \ + ((((mtu) - 1500) * 39 / 1000) + 66) +#define BNX2_RBUF_CONFIG_VAL(mtu) \ + (BNX2_RBUF_CONFIG_XOFF_TRIP_VAL(mtu) | \ + (BNX2_RBUF_CONFIG_XON_TRIP_VAL(mtu) << 16)) #define BNX2_RBUF_FW_BUF_ALLOC 0x00200010 #define BNX2_RBUF_FW_BUF_ALLOC_VALUE (0x1ffL<<7) @@ -4221,11 +4228,25 @@ struct l2_fhdr { #define BNX2_RBUF_CONFIG2 0x0020001c #define BNX2_RBUF_CONFIG2_MAC_DROP_TRIP (0x3ffL<<0) +#define BNX2_RBUF_CONFIG2_MAC_DROP_TRIP_VAL(mtu) \ + ((((mtu) - 1500) * 4 / 1000) + 5) #define BNX2_RBUF_CONFIG2_MAC_KEEP_TRIP (0x3ffL<<16) +#define BNX2_RBUF_CONFIG2_MAC_KEEP_TRIP_VAL(mtu) \ + ((((mtu) - 1500) * 2 / 100) + 30) +#define BNX2_RBUF_CONFIG2_VAL(mtu) \ + (BNX2_RBUF_CONFIG2_MAC_DROP_TRIP_VAL(mtu) | \ + (BNX2_RBUF_CONFIG2_MAC_KEEP_TRIP_VAL(mtu) << 16)) #define BNX2_RBUF_CONFIG3 0x00200020 #define BNX2_RBUF_CONFIG3_CU_DROP_TRIP (0x3ffL<<0) +#define BNX2_RBUF_CONFIG3_CU_DROP_TRIP_VAL(mtu) \ + ((((mtu) - 1500) * 12 / 1000) + 18) #define BNX2_RBUF_CONFIG3_CU_KEEP_TRIP (0x3ffL<<16) +#define BNX2_RBUF_CONFIG3_CU_KEEP_TRIP_VAL(mtu) \ + ((((mtu) - 1500) * 2 / 100) + 30) +#define BNX2_RBUF_CONFIG3_VAL(mtu) \ + (BNX2_RBUF_CONFIG3_CU_DROP_TRIP_VAL(mtu) | \ + (BNX2_RBUF_CONFIG3_CU_KEEP_TRIP_VAL(mtu) << 16)) #define BNX2_RBUF_PKT_DATA 0x00208000 #define BNX2_RBUF_CLIST_DATA 0x00210000 |