power: move power supply drivers to power/supply
This moves all power supply drivers from drivers/power/ to drivers/power/supply/. The intention is a cleaner source tree, since drivers/power/ also contains frameworks unrelated to power supply, like adaptive voltage scaling. Signed-off-by: Sebastian Reichel <sre@kernel.org>
Diffstat (limited to 'drivers/power/ab8500_bmdata.c')
-rw-r--r--drivers/power/ab8500_bmdata.c605
1 files changed, 0 insertions, 605 deletions
diff --git a/drivers/power/ab8500_bmdata.c b/drivers/power/ab8500_bmdata.c
deleted file mode 100644
index d29864533093..000000000000
--- a/drivers/power/ab8500_bmdata.c
+++ /dev/null
@@ -1,605 +0,0 @@
-#include <linux/export.h>
-#include <linux/power_supply.h>
-#include <linux/of.h>
-#include <linux/mfd/abx500.h>
-#include <linux/mfd/abx500/ab8500.h>
-#include <linux/mfd/abx500/ab8500-bm.h>
-
-/*
- * These are the defined batteries that uses a NTC and ID resistor placed
- * inside of the battery pack.
- * Note that the res_to_temp table must be strictly sorted by falling resistance
- * values to work.
- */
-const struct abx500_res_to_temp ab8500_temp_tbl_a_thermistor[] = {
- {-5, 53407},
- { 0, 48594},
- { 5, 43804},
- {10, 39188},
- {15, 34870},
- {20, 30933},
- {25, 27422},
- {30, 24347},
- {35, 21694},
- {40, 19431},
- {45, 17517},
- {50, 15908},
- {55, 14561},
- {60, 13437},
- {65, 12500},
-};
-EXPORT_SYMBOL(ab8500_temp_tbl_a_thermistor);
-
-const int ab8500_temp_tbl_a_size = ARRAY_SIZE(ab8500_temp_tbl_a_thermistor);
-EXPORT_SYMBOL(ab8500_temp_tbl_a_size);
-
-const struct abx500_res_to_temp ab8500_temp_tbl_b_thermistor[] = {
- {-5, 200000},
- { 0, 159024},
- { 5, 151921},
- {10, 144300},
- {15, 136424},
- {20, 128565},
- {25, 120978},
- {30, 113875},
- {35, 107397},
- {40, 101629},
- {45, 96592},
- {50, 92253},
- {55, 88569},
- {60, 85461},
- {65, 82869},
-};
-EXPORT_SYMBOL(ab8500_temp_tbl_b_thermistor);
-
-const int ab8500_temp_tbl_b_size = ARRAY_SIZE(ab8500_temp_tbl_b_thermistor);
-EXPORT_SYMBOL(ab8500_temp_tbl_b_size);
-
-static const struct abx500_v_to_cap cap_tbl_a_thermistor[] = {
- {4171, 100},
- {4114, 95},
- {4009, 83},
- {3947, 74},
- {3907, 67},
- {3863, 59},
- {3830, 56},
- {3813, 53},
- {3791, 46},
- {3771, 33},
- {3754, 25},
- {3735, 20},
- {3717, 17},
- {3681, 13},
- {3664, 8},
- {3651, 6},
- {3635, 5},
- {3560, 3},
- {3408, 1},
- {3247, 0},
-};
-
-static const struct abx500_v_to_cap cap_tbl_b_thermistor[] = {
- {4161, 100},
- {4124, 98},
- {4044, 90},
- {4003, 85},
- {3966, 80},
- {3933, 75},
- {3888, 67},
- {3849, 60},
- {3813, 55},
- {3787, 47},
- {3772, 30},
- {3751, 25},
- {3718, 20},
- {3681, 16},
- {3660, 14},
- {3589, 10},
- {3546, 7},
- {3495, 4},
- {3404, 2},
- {3250, 0},
-};
-
-static const struct abx500_v_to_cap cap_tbl[] = {
- {4186, 100},
- {4163, 99},
- {4114, 95},
- {4068, 90},
- {3990, 80},
- {3926, 70},
- {3898, 65},
- {3866, 60},
- {3833, 55},
- {3812, 50},
- {3787, 40},
- {3768, 30},
- {3747, 25},
- {3730, 20},
- {3705, 15},
- {3699, 14},
- {3684, 12},
- {3672, 9},
- {3657, 7},
- {3638, 6},
- {3556, 4},
- {3424, 2},
- {3317, 1},
- {3094, 0},
-};
-
-/*
- * Note that the res_to_temp table must be strictly sorted by falling
- * resistance values to work.
- */
-static const struct abx500_res_to_temp temp_tbl[] = {
- {-5, 214834},
- { 0, 162943},
- { 5, 124820},
- {10, 96520},
- {15, 75306},
- {20, 59254},
- {25, 47000},
- {30, 37566},
- {35, 30245},
- {40, 24520},
- {45, 20010},
- {50, 16432},
- {55, 13576},
- {60, 11280},
- {65, 9425},
-};
-
-/*
- * Note that the batres_vs_temp table must be strictly sorted by falling
- * temperature values to work.
- */
-static const struct batres_vs_temp temp_to_batres_tbl_thermistor[] = {
- { 40, 120},
- { 30, 135},
- { 20, 165},
- { 10, 230},
- { 00, 325},
- {-10, 445},
- {-20, 595},
-};
-
-/*
- * Note that the batres_vs_temp table must be strictly sorted by falling
- * temperature values to work.
- */
-static const struct batres_vs_temp temp_to_batres_tbl_ext_thermistor[] = {
- { 60, 300},
- { 30, 300},
- { 20, 300},
- { 10, 300},
- { 00, 300},
- {-10, 300},
- {-20, 300},
-};
-
-/* battery resistance table for LI ION 9100 battery */
-static const struct batres_vs_temp temp_to_batres_tbl_9100[] = {
- { 60, 180},
- { 30, 180},
- { 20, 180},
- { 10, 180},
- { 00, 180},
- {-10, 180},
- {-20, 180},
-};
-
-static struct abx500_battery_type bat_type_thermistor[] = {
- [BATTERY_UNKNOWN] = {
- /* First element always represent the UNKNOWN battery */
- .name = POWER_SUPPLY_TECHNOLOGY_UNKNOWN,
- .resis_high = 0,
- .resis_low = 0,
- .battery_resistance = 300,
- .charge_full_design = 612,
- .nominal_voltage = 3700,
- .termination_vol = 4050,
- .termination_curr = 200,
- .recharge_cap = 95,
- .normal_cur_lvl = 400,
- .normal_vol_lvl = 4100,
- .maint_a_cur_lvl = 400,
- .maint_a_vol_lvl = 4050,
- .maint_a_chg_timer_h = 60,
- .maint_b_cur_lvl = 400,
- .maint_b_vol_lvl = 4000,
- .maint_b_chg_timer_h = 200,
- .low_high_cur_lvl = 300,
- .low_high_vol_lvl = 4000,
- .n_temp_tbl_elements = ARRAY_SIZE(temp_tbl),
- .r_to_t_tbl = temp_tbl,
- .n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl),
- .v_to_cap_tbl = cap_tbl,
- .n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor),
- .batres_tbl = temp_to_batres_tbl_thermistor,
- },
- {
- .name = POWER_SUPPLY_TECHNOLOGY_LIPO,
- .resis_high = 53407,
- .resis_low = 12500,
- .battery_resistance = 300,
- .charge_full_design = 900,
- .nominal_voltage = 3600,
- .termination_vol = 4150,
- .termination_curr = 80,
- .recharge_cap = 95,
- .normal_cur_lvl = 700,
- .normal_vol_lvl = 4200,
- .maint_a_cur_lvl = 600,
- .maint_a_vol_lvl = 4150,
- .maint_a_chg_timer_h = 60,
- .maint_b_cur_lvl = 600,
- .maint_b_vol_lvl = 4100,
- .maint_b_chg_timer_h = 200,
- .low_high_cur_lvl = 300,
- .low_high_vol_lvl = 4000,
- .n_temp_tbl_elements = ARRAY_SIZE(ab8500_temp_tbl_a_thermistor),
- .r_to_t_tbl = ab8500_temp_tbl_a_thermistor,
- .n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl_a_thermistor),
- .v_to_cap_tbl = cap_tbl_a_thermistor,
- .n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor),
- .batres_tbl = temp_to_batres_tbl_thermistor,
-
- },
- {
- .name = POWER_SUPPLY_TECHNOLOGY_LIPO,
- .resis_high = 200000,
- .resis_low = 82869,
- .battery_resistance = 300,
- .charge_full_design = 900,
- .nominal_voltage = 3600,
- .termination_vol = 4150,
- .termination_curr = 80,
- .recharge_cap = 95,
- .normal_cur_lvl = 700,
- .normal_vol_lvl = 4200,
- .maint_a_cur_lvl = 600,
- .maint_a_vol_lvl = 4150,
- .maint_a_chg_timer_h = 60,
- .maint_b_cur_lvl = 600,
- .maint_b_vol_lvl = 4100,
- .maint_b_chg_timer_h = 200,
- .low_high_cur_lvl = 300,
- .low_high_vol_lvl = 4000,
- .n_temp_tbl_elements = ARRAY_SIZE(ab8500_temp_tbl_b_thermistor),
- .r_to_t_tbl = ab8500_temp_tbl_b_thermistor,
- .n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl_b_thermistor),
- .v_to_cap_tbl = cap_tbl_b_thermistor,
- .n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor),
- .batres_tbl = temp_to_batres_tbl_thermistor,
- },
-};
-
-static struct abx500_battery_type bat_type_ext_thermistor[] = {
- [BATTERY_UNKNOWN] = {
- /* First element always represent the UNKNOWN battery */
- .name = POWER_SUPPLY_TECHNOLOGY_UNKNOWN,
- .resis_high = 0,
- .resis_low = 0,
- .battery_resistance = 300,
- .charge_full_design = 612,
- .nominal_voltage = 3700,
- .termination_vol = 4050,
- .termination_curr = 200,
- .recharge_cap = 95,
- .normal_cur_lvl = 400,
- .normal_vol_lvl = 4100,
- .maint_a_cur_lvl = 400,
- .maint_a_vol_lvl = 4050,
- .maint_a_chg_timer_h = 60,
- .maint_b_cur_lvl = 400,
- .maint_b_vol_lvl = 4000,
- .maint_b_chg_timer_h = 200,
- .low_high_cur_lvl = 300,
- .low_high_vol_lvl = 4000,
- .n_temp_tbl_elements = ARRAY_SIZE(temp_tbl),
- .r_to_t_tbl = temp_tbl,
- .n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl),
- .v_to_cap_tbl = cap_tbl,
- .n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor),
- .batres_tbl = temp_to_batres_tbl_thermistor,
- },
-/*
- * These are the batteries that doesn't have an internal NTC resistor to measure
- * its temperature. The temperature in this case is measure with a NTC placed
- * near the battery but on the PCB.
- */
- {
- .name = POWER_SUPPLY_TECHNOLOGY_LIPO,
- .resis_high = 76000,
- .resis_low = 53000,
- .battery_resistance = 300,
- .charge_full_design = 900,
- .nominal_voltage = 3700,
- .termination_vol = 4150,
- .termination_curr = 100,
- .recharge_cap = 95,
- .normal_cur_lvl = 700,
- .normal_vol_lvl = 4200,
- .maint_a_cur_lvl = 600,
- .maint_a_vol_lvl = 4150,
- .maint_a_chg_timer_h = 60,
- .maint_b_cur_lvl = 600,
- .maint_b_vol_lvl = 4100,
- .maint_b_chg_timer_h = 200,
- .low_high_cur_lvl = 300,
- .low_high_vol_lvl = 4000,
- .n_temp_tbl_elements = ARRAY_SIZE(temp_tbl),
- .r_to_t_tbl = temp_tbl,
- .n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl),
- .v_to_cap_tbl = cap_tbl,
- .n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor),
- .batres_tbl = temp_to_batres_tbl_thermistor,
- },
- {
- .name = POWER_SUPPLY_TECHNOLOGY_LION,
- .resis_high = 30000,
- .resis_low = 10000,
- .battery_resistance = 300,
- .charge_full_design = 950,
- .nominal_voltage = 3700,
- .termination_vol = 4150,
- .termination_curr = 100,
- .recharge_cap = 95,
- .normal_cur_lvl = 700,
- .normal_vol_lvl = 4200,
- .maint_a_cur_lvl = 600,
- .maint_a_vol_lvl = 4150,
- .maint_a_chg_timer_h = 60,
- .maint_b_cur_lvl = 600,
- .maint_b_vol_lvl = 4100,
- .maint_b_chg_timer_h = 200,
- .low_high_cur_lvl = 300,
- .low_high_vol_lvl = 4000,
- .n_temp_tbl_elements = ARRAY_SIZE(temp_tbl),
- .r_to_t_tbl = temp_tbl,
- .n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl),
- .v_to_cap_tbl = cap_tbl,
- .n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor),
- .batres_tbl = temp_to_batres_tbl_thermistor,
- },
- {
- .name = POWER_SUPPLY_TECHNOLOGY_LION,
- .resis_high = 95000,
- .resis_low = 76001,
- .battery_resistance = 300,
- .charge_full_design = 950,
- .nominal_voltage = 3700,
- .termination_vol = 4150,
- .termination_curr = 100,
- .recharge_cap = 95,
- .normal_cur_lvl = 700,
- .normal_vol_lvl = 4200,
- .maint_a_cur_lvl = 600,
- .maint_a_vol_lvl = 4150,
- .maint_a_chg_timer_h = 60,
- .maint_b_cur_lvl = 600,
- .maint_b_vol_lvl = 4100,
- .maint_b_chg_timer_h = 200,
- .low_high_cur_lvl = 300,
- .low_high_vol_lvl = 4000,
- .n_temp_tbl_elements = ARRAY_SIZE(temp_tbl),
- .r_to_t_tbl = temp_tbl,
- .n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl),
- .v_to_cap_tbl = cap_tbl,
- .n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor),
- .batres_tbl = temp_to_batres_tbl_thermistor,
- },
-};
-
-static const struct abx500_bm_capacity_levels cap_levels = {
- .critical = 2,
- .low = 10,
- .normal = 70,
- .high = 95,
- .full = 100,
-};
-
-static const struct abx500_fg_parameters fg = {
- .recovery_sleep_timer = 10,
- .recovery_total_time = 100,
- .init_timer = 1,
- .init_discard_time = 5,
- .init_total_time = 40,
- .high_curr_time = 60,
- .accu_charging = 30,
- .accu_high_curr = 30,
- .high_curr_threshold = 50,
- .lowbat_threshold = 3100,
- .battok_falling_th_sel0 = 2860,
- .battok_raising_th_sel1 = 2860,
- .maint_thres = 95,
- .user_cap_limit = 15,
- .pcut_enable = 1,
- .pcut_max_time = 127,
- .pcut_flag_time = 112,
- .pcut_max_restart = 15,
- .pcut_debounce_time = 2,
-};
-
-static const struct abx500_maxim_parameters ab8500_maxi_params = {
- .ena_maxi = true,
- .chg_curr = 910,
- .wait_cycles = 10,
- .charger_curr_step = 100,
-};
-
-static const struct abx500_maxim_parameters abx540_maxi_params = {
- .ena_maxi = true,
- .chg_curr = 3000,
- .wait_cycles = 10,
- .charger_curr_step = 200,
-};
-
-static const struct abx500_bm_charger_parameters chg = {
- .usb_volt_max = 5500,
- .usb_curr_max = 1500,
- .ac_volt_max = 7500,
- .ac_curr_max = 1500,
-};
-
-/*
- * This array maps the raw hex value to charger output current used by the
- * AB8500 values
- */
-static int ab8500_charge_output_curr_map[] = {
- 100, 200, 300, 400, 500, 600, 700, 800,
- 900, 1000, 1100, 1200, 1300, 1400, 1500, 1500,
-};
-
-static int ab8540_charge_output_curr_map[] = {
- 0, 0, 0, 75, 100, 125, 150, 175,
- 200, 225, 250, 275, 300, 325, 350, 375,
- 400, 425, 450, 475, 500, 525, 550, 575,
- 600, 625, 650, 675, 700, 725, 750, 775,
- 800, 825, 850, 875, 900, 925, 950, 975,
- 1000, 1025, 1050, 1075, 1100, 1125, 1150, 1175,
- 1200, 1225, 1250, 1275, 1300, 1325, 1350, 1375,
- 1400, 1425, 1450, 1500, 1600, 1700, 1900, 2000,
-};
-
-/*
- * This array maps the raw hex value to charger input current used by the
- * AB8500 values
- */
-static int ab8500_charge_input_curr_map[] = {
- 50, 98, 193, 290, 380, 450, 500, 600,
- 700, 800, 900, 1000, 1100, 1300, 1400, 1500,
-};
-
-static int ab8540_charge_input_curr_map[] = {
- 25, 50, 75, 100, 125, 150, 175, 200,
- 225, 250, 275, 300, 325, 350, 375, 400,
- 425, 450, 475, 500, 525, 550, 575, 600,
- 625, 650, 675, 700, 725, 750, 775, 800,
- 825, 850, 875, 900, 925, 950, 975, 1000,
- 1025, 1050, 1075, 1100, 1125, 1150, 1175, 1200,
- 1225, 1250, 1275, 1300, 1325, 1350, 1375, 1400,
- 1425, 1450, 1475, 1500, 1500, 1500, 1500, 1500,
-};
-
-struct abx500_bm_data ab8500_bm_data = {
- .temp_under = 3,
- .temp_low = 8,
- .temp_high = 43,
- .temp_over = 48,
- .main_safety_tmr_h = 4,
- .temp_interval_chg = 20,
- .temp_interval_nochg = 120,
- .usb_safety_tmr_h = 4,
- .bkup_bat_v = BUP_VCH_SEL_2P6V,
- .bkup_bat_i = BUP_ICH_SEL_150UA,
- .no_maintenance = false,
- .capacity_scaling = false,
- .adc_therm = ABx500_ADC_THERM_BATCTRL,
- .chg_unknown_bat = false,
- .enable_overshoot = false,
- .fg_res = 100,
- .cap_levels = &cap_levels,
- .bat_type = bat_type_thermistor,
- .n_btypes = ARRAY_SIZE(bat_type_thermistor),
- .batt_id = 0,
- .interval_charging = 5,
- .interval_not_charging = 120,
- .temp_hysteresis = 3,
- .gnd_lift_resistance = 34,
- .chg_output_curr = ab8500_charge_output_curr_map,
- .n_chg_out_curr = ARRAY_SIZE(ab8500_charge_output_curr_map),
- .maxi = &ab8500_maxi_params,
- .chg_params = &chg,
- .fg_params = &fg,
- .chg_input_curr = ab8500_charge_input_curr_map,
- .n_chg_in_curr = ARRAY_SIZE(ab8500_charge_input_curr_map),
-};
-
-struct abx500_bm_data ab8540_bm_data = {
- .temp_under = 3,
- .temp_low = 8,
- .temp_high = 43,
- .temp_over = 48,
- .main_safety_tmr_h = 4,
- .temp_interval_chg = 20,
- .temp_interval_nochg = 120,
- .usb_safety_tmr_h = 4,
- .bkup_bat_v = BUP_VCH_SEL_2P6V,
- .bkup_bat_i = BUP_ICH_SEL_150UA,
- .no_maintenance = false,
- .capacity_scaling = false,
- .adc_therm = ABx500_ADC_THERM_BATCTRL,
- .chg_unknown_bat = false,
- .enable_overshoot = false,
- .fg_res = 100,
- .cap_levels = &cap_levels,
- .bat_type = bat_type_thermistor,
- .n_btypes = ARRAY_SIZE(bat_type_thermistor),
- .batt_id = 0,
- .interval_charging = 5,
- .interval_not_charging = 120,
- .temp_hysteresis = 3,
- .gnd_lift_resistance = 0,
- .maxi = &abx540_maxi_params,
- .chg_params = &chg,
- .fg_params = &fg,
- .chg_output_curr = ab8540_charge_output_curr_map,
- .n_chg_out_curr = ARRAY_SIZE(ab8540_charge_output_curr_map),
- .chg_input_curr = ab8540_charge_input_curr_map,
- .n_chg_in_curr = ARRAY_SIZE(ab8540_charge_input_curr_map),
-};
-
-int ab8500_bm_of_probe(struct device *dev,
- struct device_node *np,
- struct abx500_bm_data *bm)
-{
- const struct batres_vs_temp *tmp_batres_tbl;
- struct device_node *battery_node;
- const char *btech;
- int i;
-
- /* get phandle to 'battery-info' node */
- battery_node = of_parse_phandle(np, "battery", 0);
- if (!battery_node) {
- dev_err(dev, "battery node or reference missing\n");
- return -EINVAL;
- }
-
- btech = of_get_property(battery_node, "stericsson,battery-type", NULL);
- if (!btech) {
- dev_warn(dev, "missing property battery-name/type\n");
- return -EINVAL;
- }
-
- if (strncmp(btech, "LION", 4) == 0) {
- bm->no_maintenance = true;
- bm->chg_unknown_bat = true;
- bm->bat_type[BATTERY_UNKNOWN].charge_full_design = 2600;
- bm->bat_type[BATTERY_UNKNOWN].termination_vol = 4150;
- bm->bat_type[BATTERY_UNKNOWN].recharge_cap = 95;
- bm->bat_type[BATTERY_UNKNOWN].normal_cur_lvl = 520;
- bm->bat_type[BATTERY_UNKNOWN].normal_vol_lvl = 4200;
- }
-
- if (of_property_read_bool(battery_node, "thermistor-on-batctrl")) {
- if (strncmp(btech, "LION", 4) == 0)
- tmp_batres_tbl = temp_to_batres_tbl_9100;
- else
- tmp_batres_tbl = temp_to_batres_tbl_thermistor;
- } else {
- bm->n_btypes = 4;
- bm->bat_type = bat_type_ext_thermistor;
- bm->adc_therm = ABx500_ADC_THERM_BATTEMP;
- tmp_batres_tbl = temp_to_batres_tbl_ext_thermistor;
- }
-
- /* select the battery resolution table */
- for (i = 0; i < bm->n_btypes; ++i)
- bm->bat_type[i].batres_tbl = tmp_batres_tbl;
-
- of_node_put(battery_node);
-
- return 0;
-}