diff options
author | Linus Walleij <linus.walleij@linaro.org> | 2021-11-20 16:53:15 +0100 |
---|---|---|
committer | Sebastian Reichel <sebastian.reichel@collabora.com> | 2021-11-22 17:16:25 +0100 |
commit | e5dff305ab5c539320f1e30db44604e9977c3504 (patch) | |
tree | b2d11da4a72355054eeba88380fbf72343d1b6fc /drivers/power/supply/ab8500-bm.h | |
parent | power: supply: ab8500: Drop unused battery types (diff) | |
download | linux-e5dff305ab5c539320f1e30db44604e9977c3504.tar.xz linux-e5dff305ab5c539320f1e30db44604e9977c3504.zip |
power: supply: ab8500: Use only one battery type
The code was going through hoops and loops to detect what
battery is connected and check the resistance for this battery
etc.
Skip this trouble: we will support one battery (currently
"unknown") then we will find the connected battery in the
device tree using a compatible string. The battery resistance
may be used to double-check that the right battery is
connected.
Convert the array of battery types into one battery type so
we can next move over the properties of this one type into
the standard struct power_supply_battery_info.
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Diffstat (limited to 'drivers/power/supply/ab8500-bm.h')
-rw-r--r-- | drivers/power/supply/ab8500-bm.h | 4 |
1 files changed, 0 insertions, 4 deletions
diff --git a/drivers/power/supply/ab8500-bm.h b/drivers/power/supply/ab8500-bm.h index fe783610bc54..99ada7f08ec7 100644 --- a/drivers/power/supply/ab8500-bm.h +++ b/drivers/power/supply/ab8500-bm.h @@ -475,8 +475,6 @@ struct ab8500_bm_charger_parameters { * @enable_overshoot flag to enable VBAT overshoot control * @auto_trig flag to enable auto adc trigger * @fg_res resistance of FG resistor in 0.1mOhm - * @n_btypes number of elements in array bat_type - * @batt_id index of the identified battery in array bat_type * @interval_charging charge alg cycle period time when charging (sec) * @interval_not_charging charge alg cycle period time when not charging (sec) * @temp_hysteresis temperature hysteresis @@ -503,8 +501,6 @@ struct ab8500_bm_data { bool auto_trig; enum ab8500_adc_therm adc_therm; int fg_res; - int n_btypes; - int batt_id; int interval_charging; int interval_not_charging; int temp_hysteresis; |