diff options
author | Krzysztof Kozlowski <krzk@kernel.org> | 2019-01-08 13:12:12 +0100 |
---|---|---|
committer | Sebastian Reichel <sebastian.reichel@collabora.com> | 2019-01-20 22:45:08 +0100 |
commit | 02276af2fcf809b00b1fc1aede7cae6f25849e4d (patch) | |
tree | 36908c019b9f8fe6415ada9ff11b376be9c8c81e /drivers/power | |
parent | cpcap-charger: generate events for userspace (diff) | |
download | linux-02276af2fcf809b00b1fc1aede7cae6f25849e4d.tar.xz linux-02276af2fcf809b00b1fc1aede7cae6f25849e4d.zip |
power: supply: charger-manager: Fix trivial language typos
Fix few trivial language typos.
Signed-off-by: Krzysztof Kozlowski <krzk@kernel.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Diffstat (limited to 'drivers/power')
-rw-r--r-- | drivers/power/supply/charger-manager.c | 18 |
1 files changed, 9 insertions, 9 deletions
diff --git a/drivers/power/supply/charger-manager.c b/drivers/power/supply/charger-manager.c index 38be91f21cc4..2e8db5e6de0b 100644 --- a/drivers/power/supply/charger-manager.c +++ b/drivers/power/supply/charger-manager.c @@ -4,7 +4,7 @@ * * This driver enables to monitor battery health and control charger * during suspend-to-mem. - * Charger manager depends on other devices. register this later than + * Charger manager depends on other devices. Register this later than * the depending devices. * * This program is free software; you can redistribute it and/or modify @@ -29,7 +29,7 @@ #include <linux/thermal.h> /* - * Default termperature threshold for charging. + * Default temperature threshold for charging. * Every temperature units are in tenth of centigrade. */ #define CM_DEFAULT_RECHARGE_TEMP_DIFF 50 @@ -356,7 +356,7 @@ static bool is_polling_required(struct charger_manager *cm) * Note that Charger Manager keeps the charger enabled regardless whether * the charger is charging or not (because battery is full or no external * power source exists) except when CM needs to disable chargers forcibly - * bacause of emergency causes; when the battery is overheated or too cold. + * because of emergency causes; when the battery is overheated or too cold. */ static int try_charger_enable(struct charger_manager *cm, bool enable) { @@ -643,7 +643,7 @@ static int cm_check_thermal_status(struct charger_manager *cm) if (ret) { /* FIXME: * No information of battery temperature might - * occur hazadous result. We have to handle it + * occur hazardous result. We have to handle it * depending on battery type. */ dev_err(cm->dev, "Failed to get battery temperature\n"); @@ -693,7 +693,7 @@ static bool _cm_monitor(struct charger_manager *cm) uevent_notify(cm, default_event_names[temp_alrt]); /* - * Check whole charging duration and discharing duration + * Check whole charging duration and discharging duration * after full-batt. */ } else if (!cm->emergency_stop && check_charging_duration(cm)) { @@ -866,7 +866,7 @@ static void battout_handler(struct charger_manager *cm) } /** - * misc_event_handler - Handler for other evnets + * misc_event_handler - Handler for other events * @cm: the Charger Manager representing the battery. * @type: the Charger Manager representing the battery. */ @@ -1218,7 +1218,7 @@ static int charger_extcon_init(struct charger_manager *cm, } /** - * charger_manager_register_extcon - Register extcon device to recevie state + * charger_manager_register_extcon - Register extcon device to receive state * of charger cable. * @cm: the Charger Manager representing the battery. * @@ -1538,7 +1538,7 @@ static struct charger_desc *of_cm_parse_desc(struct device *dev) of_property_read_u32(np, "cm-discharging-max", &desc->discharging_max_duration_ms); - /* battery charger regualtors */ + /* battery charger regulators */ desc->num_charger_regulators = of_get_child_count(np); if (desc->num_charger_regulators) { struct charger_regulator *chg_regs; @@ -1801,7 +1801,7 @@ static int charger_manager_probe(struct platform_device *pdev) /* * Charger-manager have to check the charging state right after - * tialization of charger-manager and then update current charging + * initialization of charger-manager and then update current charging * state. */ cm_monitor(); |