summaryrefslogtreecommitdiffstats
path: root/drivers/power
diff options
context:
space:
mode:
authorHakan Berg <hakan.berg@stericsson.com>2013-01-11 14:13:01 +0100
committerAnton Vorontsov <anton@enomsg.org>2013-01-16 02:44:38 +0100
commit8bcf3b39a8776630eeec51aa1180626d66dc51aa (patch)
tree498b875b057fc752b0e527ec21d05986512efebd /drivers/power
parentab8500_btemp: Remove superfluous BTEMP thermal comp (diff)
downloadlinux-8bcf3b39a8776630eeec51aa1180626d66dc51aa.tar.xz
linux-8bcf3b39a8776630eeec51aa1180626d66dc51aa.zip
ab8500_fg: Added support for BATT_OVV
Add support for the battery over-voltage situation Signed-off-by: Lee Jones <lee.jones@linaro.org> Signed-off-by: Hakan Berg <hakan.berg@stericsson.com> Reviewed-by: Karl KOMIEROWSKI <karl.komierowski@stericsson.com> Signed-off-by: Anton Vorontsov <anton@enomsg.org>
Diffstat (limited to 'drivers/power')
-rw-r--r--drivers/power/ab8500_fg.c30
1 files changed, 15 insertions, 15 deletions
diff --git a/drivers/power/ab8500_fg.c b/drivers/power/ab8500_fg.c
index af0374620681..2917def7621c 100644
--- a/drivers/power/ab8500_fg.c
+++ b/drivers/power/ab8500_fg.c
@@ -1840,24 +1840,26 @@ static void ab8500_fg_check_hw_failure_work(struct work_struct *work)
* If we have had a battery over-voltage situation,
* check ovv-bit to see if it should be reset.
*/
- if (di->flags.bat_ovv) {
- ret = abx500_get_register_interruptible(di->dev,
- AB8500_CHARGER, AB8500_CH_STAT_REG,
- &reg_value);
- if (ret < 0) {
- dev_err(di->dev, "%s ab8500 read failed\n", __func__);
- return;
- }
- if ((reg_value & BATT_OVV) != BATT_OVV) {
- dev_dbg(di->dev, "Battery recovered from OVV\n");
- di->flags.bat_ovv = false;
+ ret = abx500_get_register_interruptible(di->dev,
+ AB8500_CHARGER, AB8500_CH_STAT_REG,
+ &reg_value);
+ if (ret < 0) {
+ dev_err(di->dev, "%s ab8500 read failed\n", __func__);
+ return;
+ }
+ if ((reg_value & BATT_OVV) == BATT_OVV) {
+ if (!di->flags.bat_ovv) {
+ dev_dbg(di->dev, "Battery OVV\n");
+ di->flags.bat_ovv = true;
power_supply_changed(&di->fg_psy);
- return;
}
-
/* Not yet recovered from ovv, reschedule this test */
queue_delayed_work(di->fg_wq, &di->fg_check_hw_failure_work,
round_jiffies(HZ));
+ } else {
+ dev_dbg(di->dev, "Battery recovered from OVV\n");
+ di->flags.bat_ovv = false;
+ power_supply_changed(&di->fg_psy);
}
}
@@ -2037,8 +2039,6 @@ static irqreturn_t ab8500_fg_batt_ovv_handler(int irq, void *_di)
struct ab8500_fg *di = _di;
dev_dbg(di->dev, "Battery OVV\n");
- di->flags.bat_ovv = true;
- power_supply_changed(&di->fg_psy);
/* Schedule a new HW failure check */
queue_delayed_work(di->fg_wq, &di->fg_check_hw_failure_work, 0);