scsi: storvsc: use default I/O timeout handler for FC devices
FC disks issue I/O directly to the host storage port driver, this is diffirent to VHD disks where I/O is virtualized and timeout is handled by the host VSP (Virtualization Service Provider). FC disks are usually setup in a multipath system, and they don't want to reset timer on I/O timeout. Timeout is detected by multipath as a good time to failover and recover. Signed-off-by: Long Li <longli@microsoft.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Diffstat (limited to 'drivers/scsi/storvsc_drv.c')
-rw-r--r--drivers/scsi/storvsc_drv.c4
1 files changed, 4 insertions, 0 deletions
diff --git a/drivers/scsi/storvsc_drv.c b/drivers/scsi/storvsc_drv.c
index 8d955db6424f..3cc8d67783a1 100644
--- a/drivers/scsi/storvsc_drv.c
+++ b/drivers/scsi/storvsc_drv.c
@@ -1495,6 +1495,10 @@ static int storvsc_host_reset_handler(struct scsi_cmnd *scmnd)
*/
static enum blk_eh_timer_return storvsc_eh_timed_out(struct scsi_cmnd *scmnd)
{
+#if IS_ENABLED(CONFIG_SCSI_FC_ATTRS)
+ if (scmnd->device->host->transportt == fc_transport_template)
+ return fc_eh_timed_out(scmnd);
+#endif
return BLK_EH_RESET_TIMER;
}