diff options
author | David Disseldorp <ddiss@suse.de> | 2018-12-05 13:18:34 +0100 |
---|---|---|
committer | Martin K. Petersen <martin.petersen@oracle.com> | 2018-12-08 03:54:33 +0100 |
commit | 0de263577de5d5e052be5f4f93334e63cc8a7f0b (patch) | |
tree | 32adf2a6187cb914ab834142c9b27f03ee72b46b /drivers/target | |
parent | scsi: qla2xxx: NULL check before some freeing functions is not needed (diff) | |
download | linux-0de263577de5d5e052be5f4f93334e63cc8a7f0b.tar.xz linux-0de263577de5d5e052be5f4f93334e63cc8a7f0b.zip |
scsi: target: use consistent left-aligned ASCII INQUIRY data
spc5r17.pdf specifies:
4.3.1 ASCII data field requirements
ASCII data fields shall contain only ASCII printable characters (i.e.,
code values 20h to 7Eh) and may be terminated with one or more ASCII null
(00h) characters. ASCII data fields described as being left-aligned
shall have any unused bytes at the end of the field (i.e., highest
offset) and the unused bytes shall be filled with ASCII space characters
(20h).
LIO currently space-pads the T10 VENDOR IDENTIFICATION and PRODUCT
IDENTIFICATION fields in the standard INQUIRY data. However, the PRODUCT
REVISION LEVEL field in the standard INQUIRY data as well as the T10 VENDOR
IDENTIFICATION field in the INQUIRY Device Identification VPD Page are
zero-terminated/zero-padded.
Fix this inconsistency by using space-padding for all of the above fields.
Signed-off-by: David Disseldorp <ddiss@suse.de>
Reviewed-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Bryant G. Ly <bly@catalogicsoftware.com>
Reviewed-by: Lee Duncan <lduncan@suse.com>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Reviewed-by: Roman Bolshakov <r.bolshakov@yadro.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Diffstat (limited to 'drivers/target')
-rw-r--r-- | drivers/target/target_core_spc.c | 17 |
1 files changed, 12 insertions, 5 deletions
diff --git a/drivers/target/target_core_spc.c b/drivers/target/target_core_spc.c index 5c49eb6f4929..e01ba2945a97 100644 --- a/drivers/target/target_core_spc.c +++ b/drivers/target/target_core_spc.c @@ -108,12 +108,17 @@ spc_emulate_inquiry_std(struct se_cmd *cmd, unsigned char *buf) buf[7] = 0x2; /* CmdQue=1 */ - memcpy(&buf[8], "LIO-ORG ", 8); - memset(&buf[16], 0x20, 16); + /* + * ASCII data fields described as being left-aligned shall have any + * unused bytes at the end of the field (i.e., highest offset) and the + * unused bytes shall be filled with ASCII space characters (20h). + */ + memset(&buf[8], 0x20, 8 + 16 + 4); + memcpy(&buf[8], "LIO-ORG", sizeof("LIO-ORG") - 1); memcpy(&buf[16], dev->t10_wwn.model, - min_t(size_t, strlen(dev->t10_wwn.model), 16)); + strnlen(dev->t10_wwn.model, 16)); memcpy(&buf[32], dev->t10_wwn.revision, - min_t(size_t, strlen(dev->t10_wwn.revision), 4)); + strnlen(dev->t10_wwn.revision, 4)); buf[4] = 31; /* Set additional length to 31 */ return 0; @@ -251,7 +256,9 @@ check_t10_vend_desc: buf[off] = 0x2; /* ASCII */ buf[off+1] = 0x1; /* T10 Vendor ID */ buf[off+2] = 0x0; - memcpy(&buf[off+4], "LIO-ORG", 8); + /* left align Vendor ID and pad with spaces */ + memset(&buf[off+4], 0x20, 8); + memcpy(&buf[off+4], "LIO-ORG", sizeof("LIO-ORG") - 1); /* Extra Byte for NULL Terminator */ id_len++; /* Identifier Length */ |