diff options
author | Kant Fan <kant@allwinnertech.com> | 2022-03-25 08:30:30 +0100 |
---|---|---|
committer | Rafael J. Wysocki <rafael.j.wysocki@intel.com> | 2022-04-13 16:49:43 +0200 |
commit | b947769b8f778db130aad834257fcaca25df2edc (patch) | |
tree | a6b1c5177df06e899e6b55690ef7079312b07e5a /drivers/thermal/devfreq_cooling.c | |
parent | thermal: hisi_termal: Switch from CONFIG_PM_SLEEP guards to pm_sleep_ptr() (diff) | |
download | linux-b947769b8f778db130aad834257fcaca25df2edc.tar.xz linux-b947769b8f778db130aad834257fcaca25df2edc.zip |
thermal: devfreq_cooling: use local ops instead of global ops
Fix access illegal address problem in following condition:
There are multiple devfreq cooling devices in system, some of them has
EM model but others do not. Energy model ops such as state2power will
append to global devfreq_cooling_ops when the cooling device with
EM model is registered. It makes the cooling device without EM model
also use devfreq_cooling_ops after appending when registered later by
of_devfreq_cooling_register_power() or of_devfreq_cooling_register().
The IPA governor regards the cooling devices without EM model as a power
actor, because they also have energy model ops, and will access illegal
address at dfc->em_pd when execute cdev->ops->get_requested_power,
cdev->ops->state2power or cdev->ops->power2state.
Fixes: 615510fe13bd2 ("thermal: devfreq_cooling: remove old power model and use EM")
Cc: 5.13+ <stable@vger.kernel.org> # 5.13+
Signed-off-by: Kant Fan <kant@allwinnertech.com>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Diffstat (limited to 'drivers/thermal/devfreq_cooling.c')
-rw-r--r-- | drivers/thermal/devfreq_cooling.c | 25 |
1 files changed, 18 insertions, 7 deletions
diff --git a/drivers/thermal/devfreq_cooling.c b/drivers/thermal/devfreq_cooling.c index 4310cb342a9f..d38a80adec73 100644 --- a/drivers/thermal/devfreq_cooling.c +++ b/drivers/thermal/devfreq_cooling.c @@ -358,21 +358,28 @@ of_devfreq_cooling_register_power(struct device_node *np, struct devfreq *df, struct thermal_cooling_device *cdev; struct device *dev = df->dev.parent; struct devfreq_cooling_device *dfc; + struct thermal_cooling_device_ops *ops; char *name; int err, num_opps; - dfc = kzalloc(sizeof(*dfc), GFP_KERNEL); - if (!dfc) + ops = kmemdup(&devfreq_cooling_ops, sizeof(*ops), GFP_KERNEL); + if (!ops) return ERR_PTR(-ENOMEM); + dfc = kzalloc(sizeof(*dfc), GFP_KERNEL); + if (!dfc) { + err = -ENOMEM; + goto free_ops; + } + dfc->devfreq = df; dfc->em_pd = em_pd_get(dev); if (dfc->em_pd) { - devfreq_cooling_ops.get_requested_power = + ops->get_requested_power = devfreq_cooling_get_requested_power; - devfreq_cooling_ops.state2power = devfreq_cooling_state2power; - devfreq_cooling_ops.power2state = devfreq_cooling_power2state; + ops->state2power = devfreq_cooling_state2power; + ops->power2state = devfreq_cooling_power2state; dfc->power_ops = dfc_power; @@ -407,8 +414,7 @@ of_devfreq_cooling_register_power(struct device_node *np, struct devfreq *df, if (!name) goto remove_qos_req; - cdev = thermal_of_cooling_device_register(np, name, dfc, - &devfreq_cooling_ops); + cdev = thermal_of_cooling_device_register(np, name, dfc, ops); kfree(name); if (IS_ERR(cdev)) { @@ -429,6 +435,8 @@ free_table: kfree(dfc->freq_table); free_dfc: kfree(dfc); +free_ops: + kfree(ops); return ERR_PTR(err); } @@ -510,11 +518,13 @@ EXPORT_SYMBOL_GPL(devfreq_cooling_em_register); void devfreq_cooling_unregister(struct thermal_cooling_device *cdev) { struct devfreq_cooling_device *dfc; + const struct thermal_cooling_device_ops *ops; struct device *dev; if (IS_ERR_OR_NULL(cdev)) return; + ops = cdev->ops; dfc = cdev->devdata; dev = dfc->devfreq->dev.parent; @@ -525,5 +535,6 @@ void devfreq_cooling_unregister(struct thermal_cooling_device *cdev) kfree(dfc->freq_table); kfree(dfc); + kfree(ops); } EXPORT_SYMBOL_GPL(devfreq_cooling_unregister); |