summaryrefslogtreecommitdiffstats
path: root/drivers/thermal
diff options
context:
space:
mode:
authorLukasz Luba <lukasz.luba@arm.com>2016-05-31 12:32:02 +0200
committerZhang Rui <rui.zhang@intel.com>2016-06-01 16:21:19 +0200
commitf840ab18bdf2e415dac21d09fbbbd2873111bd48 (patch)
tree41c3ba2ccc87af930cfaa0e2c523a9b118e3747f /drivers/thermal
parentMerge branch 'uuid' (lib/uuid fixes from Andy) (diff)
downloadlinux-f840ab18bdf2e415dac21d09fbbbd2873111bd48.tar.xz
linux-f840ab18bdf2e415dac21d09fbbbd2873111bd48.zip
thermal: cpu_cooling: fix improper order during initialization
The freq_table array is not populated before calling thermal_of_cooling_register. The code which populates the freq table was introduced in commit f6859014. This should be done before registering new thermal cooling device. The log shows effects of this wrong decision. [ 2.172614] cpu cpu1: Failed to get voltage for frequency 1984518656000: -34 [ 2.220863] cpu cpu0: Failed to get voltage for frequency 1984524416000: -34 Cc: <stable@vger.kernel.org> # 3.19+ Fixes: f6859014c7e7 ("thermal: cpu_cooling: Store frequencies in descending order") Signed-off-by: Lukasz Luba <lukasz.luba@arm.com> Acked-by: Javi Merino <javi.merino@arm.com> Acked-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Diffstat (limited to 'drivers/thermal')
-rw-r--r--drivers/thermal/cpu_cooling.c16
1 files changed, 8 insertions, 8 deletions
diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
index 6ceac4f2d4b2..5b4b47ed948b 100644
--- a/drivers/thermal/cpu_cooling.c
+++ b/drivers/thermal/cpu_cooling.c
@@ -857,14 +857,6 @@ __cpufreq_cooling_register(struct device_node *np,
goto free_power_table;
}
- snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",
- cpufreq_dev->id);
-
- cool_dev = thermal_of_cooling_device_register(np, dev_name, cpufreq_dev,
- &cpufreq_cooling_ops);
- if (IS_ERR(cool_dev))
- goto remove_idr;
-
/* Fill freq-table in descending order of frequencies */
for (i = 0, freq = -1; i <= cpufreq_dev->max_level; i++) {
freq = find_next_max(table, freq);
@@ -877,6 +869,14 @@ __cpufreq_cooling_register(struct device_node *np,
pr_debug("%s: freq:%u KHz\n", __func__, freq);
}
+ snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",
+ cpufreq_dev->id);
+
+ cool_dev = thermal_of_cooling_device_register(np, dev_name, cpufreq_dev,
+ &cpufreq_cooling_ops);
+ if (IS_ERR(cool_dev))
+ goto remove_idr;
+
cpufreq_dev->clipped_freq = cpufreq_dev->freq_table[0];
cpufreq_dev->cool_dev = cool_dev;