USB-serial: pl2303: fix baud rate handling in case of unsupported values
According to the datasheets, the PL2303 supports a set of 25 baudrates.
The baudrate is set as a 4 byte value directly.
During my experiments with device 067b:2303 (PL2303X), I noticed that
- the bridge-controller always uses 9600 baud if invalid/unsupported baud rate
values are set
- the baud rate value returned by usb_control_msg(..., GET_LINE_REQUEST, ...)
does not reflect the actually used baudrate. Always the last set value is
returned, even if it was invalid and not used by the controller.
This patch fixes the following issues with the current code:
1.) make sure that only supported baudrates are set (are there any buggy
chip revisions out there which don't "like" other values... ?).
2.) always set the baudrate to the next nearest supported baudrate.
3.) applications can now read back the resulting baudrate properly, because
tty_encode_baud_rate(...) is now fed with the actually used baudrate.
Signed-off-by: Frank Schaefer <schaefer.frank@gmx.net>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
Diffstat (limited to '')
-rw-r--r-- | drivers/usb/serial/pl2303.c | 40 |
1 files changed, 38 insertions, 2 deletions
diff --git a/drivers/usb/serial/pl2303.c b/drivers/usb/serial/pl2303.c index 4cbe59c4ae7f..82055b07e02c 100644 --- a/drivers/usb/serial/pl2303.c +++ b/drivers/usb/serial/pl2303.c @@ -528,6 +528,12 @@ static void pl2303_set_termios(struct tty_struct *tty, int baud; int i; u8 control; + const int baud_sup[] = { 75, 150, 300, 600, 1200, 1800, 2400, 3600, + 4800, 7200, 9600, 14400, 19200, 28800, 38400, + 57600, 115200, 230400, 460800, 614400, + 921600, 1228800, 2457600, 3000000, 6000000 }; + int baud_floor, baud_ceil; + int k; dbg("%s - port %d", __func__, port->number); @@ -573,9 +579,39 @@ static void pl2303_set_termios(struct tty_struct *tty, dbg("%s - data bits = %d", __func__, buf[6]); } + /* For reference buf[0]:buf[3] baud rate value */ + /* NOTE: Only the values defined in baud_sup are supported ! + * => if unsupported values are set, the PL2303 seems to use + * 9600 baud (at least my PL2303X always does) + */ baud = tty_get_baud_rate(tty); - dbg("%s - baud = %d", __func__, baud); + dbg("%s - baud requested = %d", __func__, baud); if (baud) { + /* Set baudrate to nearest supported value */ + for (k=0; k<ARRAY_SIZE(baud_sup); k++) { + if (baud_sup[k] / baud) { + baud_ceil = baud_sup[k]; + if (k==0) { + baud = baud_ceil; + } else { + baud_floor = baud_sup[k-1]; + if ((baud_ceil % baud) + > (baud % baud_floor)) + baud = baud_floor; + else + baud = baud_ceil; + } + break; + } + } + if (baud > 1228800) { + /* type_0, type_1 only support up to 1228800 baud */ + if (priv->type != HX) + baud = 1228800; + else if (baud > 6000000) + baud = 6000000; + } + dbg("%s - baud set = %d", __func__, baud); buf[0] = baud & 0xff; buf[1] = (baud >> 8) & 0xff; buf[2] = (baud >> 16) & 0xff; @@ -648,7 +684,7 @@ static void pl2303_set_termios(struct tty_struct *tty, pl2303_vendor_write(0x0, 0x0, serial); } - /* FIXME: Need to read back resulting baud rate */ + /* Save resulting baud rate */ if (baud) tty_encode_baud_rate(tty, baud, baud); |