diff options
author | Jon Mason <jdmason@kudzu.us> | 2013-09-11 20:22:39 +0200 |
---|---|---|
committer | David S. Miller <davem@davemloft.net> | 2013-09-14 02:13:00 +0200 |
commit | 29ed74c35088a775807743a5c84eecf6efa85d9f (patch) | |
tree | ef8b6b3e22cb04b7404ce343c3cf4866b67627ae /drivers | |
parent | alx: remove redundant D0 power state set (diff) | |
download | linux-29ed74c35088a775807743a5c84eecf6efa85d9f.tar.xz linux-29ed74c35088a775807743a5c84eecf6efa85d9f.zip |
bnx2x: Use pci_dev pm_cap
Use the already existing pm_cap variable in struct pci_dev for
determining the power management offset. This saves the driver from
having to keep track of an extra variable.
Signed-off-by: Jon Mason <jdmason@kudzu.us>
Cc: Eilon Greenstein <eilong@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers')
-rw-r--r-- | drivers/net/ethernet/broadcom/bnx2x/bnx2x.h | 1 | ||||
-rw-r--r-- | drivers/net/ethernet/broadcom/bnx2x/bnx2x_cmn.c | 8 | ||||
-rw-r--r-- | drivers/net/ethernet/broadcom/bnx2x/bnx2x_ethtool.c | 4 | ||||
-rw-r--r-- | drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c | 10 |
4 files changed, 11 insertions, 12 deletions
diff --git a/drivers/net/ethernet/broadcom/bnx2x/bnx2x.h b/drivers/net/ethernet/broadcom/bnx2x/bnx2x.h index 0c338026ce01..70b6a05834d1 100644 --- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x.h +++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x.h @@ -1542,7 +1542,6 @@ struct bnx2x { */ bool fcoe_init; - int pm_cap; int mrrs; struct delayed_work sp_task; diff --git a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_cmn.c b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_cmn.c index 90045c920d09..61726af1de6e 100644 --- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_cmn.c +++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_cmn.c @@ -3008,16 +3008,16 @@ int bnx2x_set_power_state(struct bnx2x *bp, pci_power_t state) u16 pmcsr; /* If there is no power capability, silently succeed */ - if (!bp->pm_cap) { + if (!bp->pdev->pm_cap) { BNX2X_DEV_INFO("No power capability. Breaking.\n"); return 0; } - pci_read_config_word(bp->pdev, bp->pm_cap + PCI_PM_CTRL, &pmcsr); + pci_read_config_word(bp->pdev, bp->pdev->pm_cap + PCI_PM_CTRL, &pmcsr); switch (state) { case PCI_D0: - pci_write_config_word(bp->pdev, bp->pm_cap + PCI_PM_CTRL, + pci_write_config_word(bp->pdev, bp->pdev->pm_cap + PCI_PM_CTRL, ((pmcsr & ~PCI_PM_CTRL_STATE_MASK) | PCI_PM_CTRL_PME_STATUS)); @@ -3041,7 +3041,7 @@ int bnx2x_set_power_state(struct bnx2x *bp, pci_power_t state) if (bp->wol) pmcsr |= PCI_PM_CTRL_PME_ENABLE; - pci_write_config_word(bp->pdev, bp->pm_cap + PCI_PM_CTRL, + pci_write_config_word(bp->pdev, bp->pdev->pm_cap + PCI_PM_CTRL, pmcsr); /* No more memory access after this point until diff --git a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_ethtool.c b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_ethtool.c index 2612e3c715d4..324de5f05332 100644 --- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_ethtool.c +++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_ethtool.c @@ -1387,9 +1387,9 @@ static bool bnx2x_is_nvm_accessible(struct bnx2x *bp) u16 pm = 0; struct net_device *dev = pci_get_drvdata(bp->pdev); - if (bp->pm_cap) + if (bp->pdev->pm_cap) rc = pci_read_config_word(bp->pdev, - bp->pm_cap + PCI_PM_CTRL, &pm); + bp->pdev->pm_cap + PCI_PM_CTRL, &pm); if ((rc && !netif_running(dev)) || (!rc && ((pm & PCI_PM_CTRL_STATE_MASK) != (__force u16)PCI_D0))) diff --git a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c index 2f8dbbbd7a86..62c59eda1239 100644 --- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c +++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c @@ -8652,6 +8652,7 @@ u32 bnx2x_send_unload_req(struct bnx2x *bp, int unload_mode) else if (bp->wol) { u32 emac_base = port ? GRCBASE_EMAC1 : GRCBASE_EMAC0; u8 *mac_addr = bp->dev->dev_addr; + struct pci_dev *pdev = bp->pdev; u32 val; u16 pmc; @@ -8668,9 +8669,9 @@ u32 bnx2x_send_unload_req(struct bnx2x *bp, int unload_mode) EMAC_WR(bp, EMAC_REG_EMAC_MAC_MATCH + entry + 4, val); /* Enable the PME and clear the status */ - pci_read_config_word(bp->pdev, bp->pm_cap + PCI_PM_CTRL, &pmc); + pci_read_config_word(pdev, pdev->pm_cap + PCI_PM_CTRL, &pmc); pmc |= PCI_PM_CTRL_PME_ENABLE | PCI_PM_CTRL_PME_STATUS; - pci_write_config_word(bp->pdev, bp->pm_cap + PCI_PM_CTRL, pmc); + pci_write_config_word(pdev, pdev->pm_cap + PCI_PM_CTRL, pmc); reset_code = DRV_MSG_CODE_UNLOAD_REQ_WOL_EN; @@ -10399,7 +10400,7 @@ static void bnx2x_get_common_hwinfo(struct bnx2x *bp) break; } - pci_read_config_word(bp->pdev, bp->pm_cap + PCI_PM_PMC, &pmc); + pci_read_config_word(bp->pdev, bp->pdev->pm_cap + PCI_PM_PMC, &pmc); bp->flags |= (pmc & PCI_PM_CAP_PME_D3cold) ? 0 : NO_WOL_FLAG; BNX2X_DEV_INFO("%sWoL capable\n", @@ -12141,8 +12142,7 @@ static int bnx2x_init_dev(struct bnx2x *bp, struct pci_dev *pdev, } if (IS_PF(bp)) { - bp->pm_cap = pdev->pm_cap; - if (bp->pm_cap == 0) { + if (!pdev->pm_cap) { dev_err(&bp->pdev->dev, "Cannot find power management capability, aborting\n"); rc = -EIO; |