diff options
author | Alexandre Rames <arames@solarflare.com> | 2013-06-10 12:03:21 +0200 |
---|---|---|
committer | Ben Hutchings <bhutchings@solarflare.com> | 2013-08-29 19:12:13 +0200 |
commit | 3881d8ab065b23bb07400aa820e737d80fdaced3 (patch) | |
tree | 646f9543591f8cfcf20d40e1cdb0d7046f9fa9cc /drivers | |
parent | sfc: Prepare for RX scatter on EF10 (diff) | |
download | linux-3881d8ab065b23bb07400aa820e737d80fdaced3.tar.xz linux-3881d8ab065b23bb07400aa820e737d80fdaced3.zip |
sfc: Use a global count of active queues instead of pending drains
On EF10, the firmware will initiate a queue flush in certain
error cases. We need to accept that flush events might appear
at any time after a queue has been initialised, not just when
we try to flush them.
We can handle Falcon-architecture in just the same way.
Signed-off-by: Ben Hutchings <bhutchings@solarflare.com>
Diffstat (limited to 'drivers')
-rw-r--r-- | drivers/net/ethernet/sfc/efx.c | 5 | ||||
-rw-r--r-- | drivers/net/ethernet/sfc/farch.c | 18 | ||||
-rw-r--r-- | drivers/net/ethernet/sfc/net_driver.h | 4 |
3 files changed, 14 insertions, 13 deletions
diff --git a/drivers/net/ethernet/sfc/efx.c b/drivers/net/ethernet/sfc/efx.c index b4832230d744..34788fbb4c66 100644 --- a/drivers/net/ethernet/sfc/efx.c +++ b/drivers/net/ethernet/sfc/efx.c @@ -631,11 +631,14 @@ static void efx_start_datapath(struct efx_nic *efx) /* Initialise the channels */ efx_for_each_channel(channel, efx) { - efx_for_each_channel_tx_queue(tx_queue, channel) + efx_for_each_channel_tx_queue(tx_queue, channel) { efx_init_tx_queue(tx_queue); + atomic_inc(&efx->active_queues); + } efx_for_each_channel_rx_queue(rx_queue, channel) { efx_init_rx_queue(rx_queue); + atomic_inc(&efx->active_queues); efx_nic_generate_fill_event(rx_queue); } diff --git a/drivers/net/ethernet/sfc/farch.c b/drivers/net/ethernet/sfc/farch.c index eb754cfff1ef..842f92e45517 100644 --- a/drivers/net/ethernet/sfc/farch.c +++ b/drivers/net/ethernet/sfc/farch.c @@ -594,7 +594,7 @@ static bool efx_farch_flush_wake(struct efx_nic *efx) /* Ensure that all updates are visible to efx_farch_flush_queues() */ smp_mb(); - return (atomic_read(&efx->drain_pending) == 0 || + return (atomic_read(&efx->active_queues) == 0 || (atomic_read(&efx->rxq_flush_outstanding) < EFX_RX_FLUSH_COUNT && atomic_read(&efx->rxq_flush_pending) > 0)); } @@ -626,7 +626,7 @@ static bool efx_check_tx_flush_complete(struct efx_nic *efx) netif_dbg(efx, hw, efx->net_dev, "flush complete on TXQ %d, so drain " "the queue\n", tx_queue->queue); - /* Don't need to increment drain_pending as it + /* Don't need to increment active_queues as it * has already been incremented for the queues * which did not drain */ @@ -653,17 +653,15 @@ static int efx_farch_do_flush(struct efx_nic *efx) efx_for_each_channel(channel, efx) { efx_for_each_channel_tx_queue(tx_queue, channel) { - atomic_inc(&efx->drain_pending); efx_farch_flush_tx_queue(tx_queue); } efx_for_each_channel_rx_queue(rx_queue, channel) { - atomic_inc(&efx->drain_pending); rx_queue->flush_pending = true; atomic_inc(&efx->rxq_flush_pending); } } - while (timeout && atomic_read(&efx->drain_pending) > 0) { + while (timeout && atomic_read(&efx->active_queues) > 0) { /* If SRIOV is enabled, then offload receive queue flushing to * the firmware (though we will still have to poll for * completion). If that fails, fall back to the old scheme. @@ -699,15 +697,15 @@ static int efx_farch_do_flush(struct efx_nic *efx) timeout); } - if (atomic_read(&efx->drain_pending) && + if (atomic_read(&efx->active_queues) && !efx_check_tx_flush_complete(efx)) { netif_err(efx, hw, efx->net_dev, "failed to flush %d queues " - "(rx %d+%d)\n", atomic_read(&efx->drain_pending), + "(rx %d+%d)\n", atomic_read(&efx->active_queues), atomic_read(&efx->rxq_flush_outstanding), atomic_read(&efx->rxq_flush_pending)); rc = -ETIMEDOUT; - atomic_set(&efx->drain_pending, 0); + atomic_set(&efx->active_queues, 0); atomic_set(&efx->rxq_flush_pending, 0); atomic_set(&efx->rxq_flush_outstanding, 0); } @@ -1123,8 +1121,8 @@ efx_farch_handle_drain_event(struct efx_channel *channel) { struct efx_nic *efx = channel->efx; - WARN_ON(atomic_read(&efx->drain_pending) == 0); - atomic_dec(&efx->drain_pending); + WARN_ON(atomic_read(&efx->active_queues) == 0); + atomic_dec(&efx->active_queues); if (efx_farch_flush_wake(efx)) wake_up(&efx->flush_wq); } diff --git a/drivers/net/ethernet/sfc/net_driver.h b/drivers/net/ethernet/sfc/net_driver.h index 5341c76b1d02..c9b6f2dcb539 100644 --- a/drivers/net/ethernet/sfc/net_driver.h +++ b/drivers/net/ethernet/sfc/net_driver.h @@ -723,7 +723,7 @@ struct vfdi_status; * @rps_flow_id: Flow IDs of filters allocated for accelerated RFS, * indexed by filter ID * @rps_expire_index: Next index to check for expiry in @rps_flow_id - * @drain_pending: Count of RX and TX queues that haven't been flushed and drained. + * @active_queues: Count of RX and TX queues that haven't been flushed and drained. * @rxq_flush_pending: Count of number of receive queues that need to be flushed. * Decremented when the efx_flush_rx_queue() is called. * @rxq_flush_outstanding: Count of number of RX flushes started but not yet @@ -864,7 +864,7 @@ struct efx_nic { unsigned int rps_expire_index; #endif - atomic_t drain_pending; + atomic_t active_queues; atomic_t rxq_flush_pending; atomic_t rxq_flush_outstanding; wait_queue_head_t flush_wq; |