diff options
author | Damien Le Moal <damien.lemoal@opensource.wdc.com> | 2022-11-24 11:43:30 +0100 |
---|---|---|
committer | Damien Le Moal <damien.lemoal@opensource.wdc.com> | 2023-01-23 01:25:51 +0100 |
commit | 34422914dc00b291d1c47dbdabe93b154c2f2b25 (patch) | |
tree | cfdee6d1827c4ae351743d38e4086457958fd96b /fs/zonefs | |
parent | zonefs: Simplify IO error handling (diff) | |
download | linux-34422914dc00b291d1c47dbdabe93b154c2f2b25.tar.xz linux-34422914dc00b291d1c47dbdabe93b154c2f2b25.zip |
zonefs: Reduce struct zonefs_inode_info size
Instead of using the i_ztype field in struct zonefs_inode_info to
indicate the zone type of an inode, introduce the new inode flag
ZONEFS_ZONE_CNV to be set in the i_flags field of struct
zonefs_inode_info to identify conventional zones. If this flag is not
set, the zone of an inode is considered to be a sequential zone.
The helpers zonefs_zone_is_cnv(), zonefs_zone_is_seq(),
zonefs_inode_is_cnv() and zonefs_inode_is_seq() are introduced to
simplify testing the zone type of a struct zonefs_inode_info and of a
struct inode.
Signed-off-by: Damien Le Moal <damien.lemoal@opensource.wdc.com>
Reviewed-by: Johannes Thumshirn <johannes.thumshirn@wdc.com>
Diffstat (limited to 'fs/zonefs')
-rw-r--r-- | fs/zonefs/file.c | 35 | ||||
-rw-r--r-- | fs/zonefs/super.c | 12 | ||||
-rw-r--r-- | fs/zonefs/zonefs.h | 24 |
3 files changed, 42 insertions, 29 deletions
diff --git a/fs/zonefs/file.c b/fs/zonefs/file.c index ece0f3959b6d..64873d31d75d 100644 --- a/fs/zonefs/file.c +++ b/fs/zonefs/file.c @@ -77,8 +77,7 @@ static int zonefs_write_iomap_begin(struct inode *inode, loff_t offset, * checked when writes are issued, so warn if we see a page writeback * operation. */ - if (WARN_ON_ONCE(zi->i_ztype == ZONEFS_ZTYPE_SEQ && - !(flags & IOMAP_DIRECT))) + if (WARN_ON_ONCE(zonefs_zone_is_seq(zi) && !(flags & IOMAP_DIRECT))) return -EIO; /* @@ -128,7 +127,7 @@ static int zonefs_write_map_blocks(struct iomap_writepage_ctx *wpc, { struct zonefs_inode_info *zi = ZONEFS_I(inode); - if (WARN_ON_ONCE(zi->i_ztype != ZONEFS_ZTYPE_CNV)) + if (WARN_ON_ONCE(zonefs_zone_is_seq(zi))) return -EIO; if (WARN_ON_ONCE(offset >= i_size_read(inode))) return -EIO; @@ -158,9 +157,8 @@ static int zonefs_swap_activate(struct swap_info_struct *sis, struct file *swap_file, sector_t *span) { struct inode *inode = file_inode(swap_file); - struct zonefs_inode_info *zi = ZONEFS_I(inode); - if (zi->i_ztype != ZONEFS_ZTYPE_CNV) { + if (zonefs_inode_is_seq(inode)) { zonefs_err(inode->i_sb, "swap file: not a conventional zone file\n"); return -EINVAL; @@ -196,7 +194,7 @@ int zonefs_file_truncate(struct inode *inode, loff_t isize) * only down to a 0 size, which is equivalent to a zone reset, and to * the maximum file size, which is equivalent to a zone finish. */ - if (zi->i_ztype != ZONEFS_ZTYPE_SEQ) + if (!zonefs_zone_is_seq(zi)) return -EPERM; if (!isize) @@ -266,7 +264,7 @@ static int zonefs_file_fsync(struct file *file, loff_t start, loff_t end, * Since only direct writes are allowed in sequential files, page cache * flush is needed only for conventional zone files. */ - if (ZONEFS_I(inode)->i_ztype == ZONEFS_ZTYPE_CNV) + if (zonefs_inode_is_cnv(inode)) ret = file_write_and_wait_range(file, start, end); if (!ret) ret = blkdev_issue_flush(inode->i_sb->s_bdev); @@ -280,7 +278,6 @@ static int zonefs_file_fsync(struct file *file, loff_t start, loff_t end, static vm_fault_t zonefs_filemap_page_mkwrite(struct vm_fault *vmf) { struct inode *inode = file_inode(vmf->vma->vm_file); - struct zonefs_inode_info *zi = ZONEFS_I(inode); vm_fault_t ret; if (unlikely(IS_IMMUTABLE(inode))) @@ -290,7 +287,7 @@ static vm_fault_t zonefs_filemap_page_mkwrite(struct vm_fault *vmf) * Sanity check: only conventional zone files can have shared * writeable mappings. */ - if (WARN_ON_ONCE(zi->i_ztype != ZONEFS_ZTYPE_CNV)) + if (zonefs_inode_is_seq(inode)) return VM_FAULT_NOPAGE; sb_start_pagefault(inode->i_sb); @@ -319,7 +316,7 @@ static int zonefs_file_mmap(struct file *file, struct vm_area_struct *vma) * mappings are possible since there are no guarantees for write * ordering between msync() and page cache writeback. */ - if (ZONEFS_I(file_inode(file))->i_ztype == ZONEFS_ZTYPE_SEQ && + if (zonefs_inode_is_seq(file_inode(file)) && (vma->vm_flags & VM_SHARED) && (vma->vm_flags & VM_MAYWRITE)) return -EINVAL; @@ -352,7 +349,7 @@ static int zonefs_file_write_dio_end_io(struct kiocb *iocb, ssize_t size, return error; } - if (size && zi->i_ztype != ZONEFS_ZTYPE_CNV) { + if (size && zonefs_zone_is_seq(zi)) { /* * Note that we may be seeing completions out of order, * but that is not a problem since a write completed @@ -491,7 +488,7 @@ static ssize_t zonefs_write_checks(struct kiocb *iocb, struct iov_iter *from) return -EINVAL; if (iocb->ki_flags & IOCB_APPEND) { - if (zi->i_ztype != ZONEFS_ZTYPE_SEQ) + if (zonefs_zone_is_cnv(zi)) return -EINVAL; mutex_lock(&zi->i_truncate_mutex); iocb->ki_pos = zi->i_wpoffset; @@ -531,8 +528,7 @@ static ssize_t zonefs_file_dio_write(struct kiocb *iocb, struct iov_iter *from) * as this can cause write reordering (e.g. the first aio gets EAGAIN * on the inode lock but the second goes through but is now unaligned). */ - if (zi->i_ztype == ZONEFS_ZTYPE_SEQ && !sync && - (iocb->ki_flags & IOCB_NOWAIT)) + if (zonefs_zone_is_seq(zi) && !sync && (iocb->ki_flags & IOCB_NOWAIT)) return -EOPNOTSUPP; if (iocb->ki_flags & IOCB_NOWAIT) { @@ -554,7 +550,7 @@ static ssize_t zonefs_file_dio_write(struct kiocb *iocb, struct iov_iter *from) } /* Enforce sequential writes (append only) in sequential zones */ - if (zi->i_ztype == ZONEFS_ZTYPE_SEQ) { + if (zonefs_zone_is_seq(zi)) { mutex_lock(&zi->i_truncate_mutex); if (iocb->ki_pos != zi->i_wpoffset) { mutex_unlock(&zi->i_truncate_mutex); @@ -570,7 +566,7 @@ static ssize_t zonefs_file_dio_write(struct kiocb *iocb, struct iov_iter *from) else ret = iomap_dio_rw(iocb, from, &zonefs_write_iomap_ops, &zonefs_write_dio_ops, 0, NULL, 0); - if (zi->i_ztype == ZONEFS_ZTYPE_SEQ && + if (zonefs_zone_is_seq(zi) && (ret > 0 || ret == -EIOCBQUEUED)) { if (ret > 0) count = ret; @@ -596,14 +592,13 @@ static ssize_t zonefs_file_buffered_write(struct kiocb *iocb, struct iov_iter *from) { struct inode *inode = file_inode(iocb->ki_filp); - struct zonefs_inode_info *zi = ZONEFS_I(inode); ssize_t ret; /* * Direct IO writes are mandatory for sequential zone files so that the * write IO issuing order is preserved. */ - if (zi->i_ztype != ZONEFS_ZTYPE_CNV) + if (zonefs_inode_is_seq(inode)) return -EIO; if (iocb->ki_flags & IOCB_NOWAIT) { @@ -731,9 +726,7 @@ inode_unlock: static inline bool zonefs_seq_file_need_wro(struct inode *inode, struct file *file) { - struct zonefs_inode_info *zi = ZONEFS_I(inode); - - if (zi->i_ztype != ZONEFS_ZTYPE_SEQ) + if (zonefs_inode_is_cnv(inode)) return false; if (!(file->f_mode & FMODE_WRITE)) diff --git a/fs/zonefs/super.c b/fs/zonefs/super.c index 6307cc95be06..a4af29dc32e7 100644 --- a/fs/zonefs/super.c +++ b/fs/zonefs/super.c @@ -37,7 +37,7 @@ void zonefs_account_active(struct inode *inode) lockdep_assert_held(&zi->i_truncate_mutex); - if (zi->i_ztype != ZONEFS_ZTYPE_SEQ) + if (zonefs_zone_is_cnv(zi)) return; /* @@ -177,14 +177,14 @@ static loff_t zonefs_check_zone_condition(struct inode *inode, zonefs_warn(inode->i_sb, "inode %lu: read-only zone\n", inode->i_ino); zi->i_flags |= ZONEFS_ZONE_READONLY; - if (zi->i_ztype == ZONEFS_ZTYPE_CNV) + if (zonefs_zone_is_cnv(zi)) return zi->i_max_size; return zi->i_wpoffset; case BLK_ZONE_COND_FULL: /* The write pointer of full zones is invalid. */ return zi->i_max_size; default: - if (zi->i_ztype == ZONEFS_ZTYPE_CNV) + if (zonefs_zone_is_cnv(zi)) return zi->i_max_size; return (zone->wp - zone->start) << SECTOR_SHIFT; } @@ -260,7 +260,7 @@ static int zonefs_io_error_cb(struct blk_zone *zone, unsigned int idx, * In all cases, warn about inode size inconsistency and handle the * IO error according to the zone condition and to the mount options. */ - if (zi->i_ztype == ZONEFS_ZTYPE_SEQ && isize != data_size) + if (zonefs_zone_is_seq(zi) && isize != data_size) zonefs_warn(sb, "inode %lu: invalid size %lld (should be %lld)\n", inode->i_ino, isize, data_size); @@ -584,7 +584,9 @@ static int zonefs_init_file_inode(struct inode *inode, struct blk_zone *zone, inode->i_ino = zone->start >> sbi->s_zone_sectors_shift; inode->i_mode = S_IFREG | sbi->s_perm; - zi->i_ztype = type; + if (type == ZONEFS_ZTYPE_CNV) + zi->i_flags |= ZONEFS_ZONE_CNV; + zi->i_zsector = zone->start; zi->i_zone_size = zone->len << SECTOR_SHIFT; if (zi->i_zone_size > bdev_zone_sectors(sb->s_bdev) << SECTOR_SHIFT && diff --git a/fs/zonefs/zonefs.h b/fs/zonefs/zonefs.h index 439096445ee5..1a225f74015a 100644 --- a/fs/zonefs/zonefs.h +++ b/fs/zonefs/zonefs.h @@ -44,6 +44,7 @@ static inline enum zonefs_ztype zonefs_zone_type(struct blk_zone *zone) #define ZONEFS_ZONE_ACTIVE (1U << 2) #define ZONEFS_ZONE_OFFLINE (1U << 3) #define ZONEFS_ZONE_READONLY (1U << 4) +#define ZONEFS_ZONE_CNV (1U << 31) /* * In-memory inode data. @@ -51,9 +52,6 @@ static inline enum zonefs_ztype zonefs_zone_type(struct blk_zone *zone) struct zonefs_inode_info { struct inode i_vnode; - /* File zone type */ - enum zonefs_ztype i_ztype; - /* File zone start sector (512B unit) */ sector_t i_zsector; @@ -91,6 +89,26 @@ static inline struct zonefs_inode_info *ZONEFS_I(struct inode *inode) return container_of(inode, struct zonefs_inode_info, i_vnode); } +static inline bool zonefs_zone_is_cnv(struct zonefs_inode_info *zi) +{ + return zi->i_flags & ZONEFS_ZONE_CNV; +} + +static inline bool zonefs_zone_is_seq(struct zonefs_inode_info *zi) +{ + return !zonefs_zone_is_cnv(zi); +} + +static inline bool zonefs_inode_is_cnv(struct inode *inode) +{ + return zonefs_zone_is_cnv(ZONEFS_I(inode)); +} + +static inline bool zonefs_inode_is_seq(struct inode *inode) +{ + return zonefs_zone_is_seq(ZONEFS_I(inode)); +} + /* * On-disk super block (block 0). */ |