diff options
author | Vincent Guittot <vincent.guittot@linaro.org> | 2023-02-01 15:36:28 +0100 |
---|---|---|
committer | Peter Zijlstra <peterz@infradead.org> | 2023-02-11 11:18:09 +0100 |
commit | a2e90611b9f425adbbfcdaa5b5e49958ddf6f61b (patch) | |
tree | f9274d67b2d1ef68b9c972176386ff225d982105 /kernel/sched | |
parent | sched/fair: unlink misfit task from cpu overutilized (diff) | |
download | linux-a2e90611b9f425adbbfcdaa5b5e49958ddf6f61b.tar.xz linux-a2e90611b9f425adbbfcdaa5b5e49958ddf6f61b.zip |
sched/fair: Remove capacity inversion detection
Remove the capacity inversion detection which is now handled by
util_fits_cpu() returning -1 when we need to continue to look for a
potential CPU with better performance.
This ends up almost reverting patches below except for some comments:
commit da07d2f9c153 ("sched/fair: Fixes for capacity inversion detection")
commit aa69c36f31aa ("sched/fair: Consider capacity inversion in util_fits_cpu()")
commit 44c7b80bffc3 ("sched/fair: Detect capacity inversion")
Signed-off-by: Vincent Guittot <vincent.guittot@linaro.org>
Signed-off-by: Peter Zijlstra (Intel) <peterz@infradead.org>
Link: https://lore.kernel.org/r/20230201143628.270912-3-vincent.guittot@linaro.org
Diffstat (limited to 'kernel/sched')
-rw-r--r-- | kernel/sched/fair.c | 84 | ||||
-rw-r--r-- | kernel/sched/sched.h | 19 |
2 files changed, 5 insertions, 98 deletions
diff --git a/kernel/sched/fair.c b/kernel/sched/fair.c index 074742f107c0..c6c8e7f52935 100644 --- a/kernel/sched/fair.c +++ b/kernel/sched/fair.c @@ -4476,17 +4476,9 @@ static inline int util_fits_cpu(unsigned long util, * * For uclamp_max, we can tolerate a drop in performance level as the * goal is to cap the task. So it's okay if it's getting less. - * - * In case of capacity inversion we should honour the inverted capacity - * for both uclamp_min and uclamp_max all the time. */ - capacity_orig = cpu_in_capacity_inversion(cpu); - if (capacity_orig) { - capacity_orig_thermal = capacity_orig; - } else { - capacity_orig = capacity_orig_of(cpu); - capacity_orig_thermal = capacity_orig - arch_scale_thermal_pressure(cpu); - } + capacity_orig = capacity_orig_of(cpu); + capacity_orig_thermal = capacity_orig - arch_scale_thermal_pressure(cpu); /* * We want to force a task to fit a cpu as implied by uclamp_max. @@ -9027,82 +9019,16 @@ static unsigned long scale_rt_capacity(int cpu) static void update_cpu_capacity(struct sched_domain *sd, int cpu) { - unsigned long capacity_orig = arch_scale_cpu_capacity(cpu); unsigned long capacity = scale_rt_capacity(cpu); struct sched_group *sdg = sd->groups; - struct rq *rq = cpu_rq(cpu); - rq->cpu_capacity_orig = capacity_orig; + cpu_rq(cpu)->cpu_capacity_orig = arch_scale_cpu_capacity(cpu); if (!capacity) capacity = 1; - rq->cpu_capacity = capacity; - - /* - * Detect if the performance domain is in capacity inversion state. - * - * Capacity inversion happens when another perf domain with equal or - * lower capacity_orig_of() ends up having higher capacity than this - * domain after subtracting thermal pressure. - * - * We only take into account thermal pressure in this detection as it's - * the only metric that actually results in *real* reduction of - * capacity due to performance points (OPPs) being dropped/become - * unreachable due to thermal throttling. - * - * We assume: - * * That all cpus in a perf domain have the same capacity_orig - * (same uArch). - * * Thermal pressure will impact all cpus in this perf domain - * equally. - */ - if (sched_energy_enabled()) { - unsigned long inv_cap = capacity_orig - thermal_load_avg(rq); - struct perf_domain *pd; - - rcu_read_lock(); - - pd = rcu_dereference(rq->rd->pd); - rq->cpu_capacity_inverted = 0; - - for (; pd; pd = pd->next) { - struct cpumask *pd_span = perf_domain_span(pd); - unsigned long pd_cap_orig, pd_cap; - - /* We can't be inverted against our own pd */ - if (cpumask_test_cpu(cpu_of(rq), pd_span)) - continue; - - cpu = cpumask_any(pd_span); - pd_cap_orig = arch_scale_cpu_capacity(cpu); - - if (capacity_orig < pd_cap_orig) - continue; - - /* - * handle the case of multiple perf domains have the - * same capacity_orig but one of them is under higher - * thermal pressure. We record it as capacity - * inversion. - */ - if (capacity_orig == pd_cap_orig) { - pd_cap = pd_cap_orig - thermal_load_avg(cpu_rq(cpu)); - - if (pd_cap > inv_cap) { - rq->cpu_capacity_inverted = inv_cap; - break; - } - } else if (pd_cap_orig > inv_cap) { - rq->cpu_capacity_inverted = inv_cap; - break; - } - } - - rcu_read_unlock(); - } - - trace_sched_cpu_capacity_tp(rq); + cpu_rq(cpu)->cpu_capacity = capacity; + trace_sched_cpu_capacity_tp(cpu_rq(cpu)); sdg->sgc->capacity = capacity; sdg->sgc->min_capacity = capacity; diff --git a/kernel/sched/sched.h b/kernel/sched/sched.h index 1072502976df..3e8df6d31c1e 100644 --- a/kernel/sched/sched.h +++ b/kernel/sched/sched.h @@ -1044,7 +1044,6 @@ struct rq { unsigned long cpu_capacity; unsigned long cpu_capacity_orig; - unsigned long cpu_capacity_inverted; struct balance_callback *balance_callback; @@ -2899,24 +2898,6 @@ static inline unsigned long capacity_orig_of(int cpu) return cpu_rq(cpu)->cpu_capacity_orig; } -/* - * Returns inverted capacity if the CPU is in capacity inversion state. - * 0 otherwise. - * - * Capacity inversion detection only considers thermal impact where actual - * performance points (OPPs) gets dropped. - * - * Capacity inversion state happens when another performance domain that has - * equal or lower capacity_orig_of() becomes effectively larger than the perf - * domain this CPU belongs to due to thermal pressure throttling it hard. - * - * See comment in update_cpu_capacity(). - */ -static inline unsigned long cpu_in_capacity_inversion(int cpu) -{ - return cpu_rq(cpu)->cpu_capacity_inverted; -} - /** * enum cpu_util_type - CPU utilization type * @FREQUENCY_UTIL: Utilization used to select frequency |