summaryrefslogtreecommitdiffstats
path: root/net/bridge
diff options
context:
space:
mode:
authorVladimir Oltean <olteanv@gmail.com>2019-08-30 02:53:24 +0200
committerDavid S. Miller <davem@davemloft.net>2019-08-31 22:21:19 +0200
commitf40d9b20864ae571c31f57989fd869958ce675c2 (patch)
tree378b6fe6794fbb184cf04b207f627cb9f73bbdf4 /net/bridge
parentMerge tag 'batadv-next-for-davem-20190830' of git://git.open-mesh.org/linux-m... (diff)
downloadlinux-f40d9b20864ae571c31f57989fd869958ce675c2.tar.xz
linux-f40d9b20864ae571c31f57989fd869958ce675c2.zip
net: bridge: Populate the pvid flag in br_vlan_get_info
Currently this simplified code snippet fails: br_vlan_get_pvid(netdev, &pvid); br_vlan_get_info(netdev, pvid, &vinfo); ASSERT(!(vinfo.flags & BRIDGE_VLAN_INFO_PVID)); It is intuitive that the pvid of a netdevice should have the BRIDGE_VLAN_INFO_PVID flag set. However I can't seem to pinpoint a commit where this behavior was introduced. It seems like it's been like that since forever. At a first glance it would make more sense to just handle the BRIDGE_VLAN_INFO_PVID flag in __vlan_add_flags. However, as Nikolay explains: There are a few reasons why we don't do it, most importantly because we need to have only one visible pvid at any single time, even if it's stale - it must be just one. Right now that rule will not be violated by this change, but people will try using this flag and could see two pvids simultaneously. You can see that the pvid code is even using memory barriers to propagate the new value faster and everywhere the pvid is read only once. That is the reason the flag is set dynamically when dumping entries, too. A second (weaker) argument against would be given the above we don't want another way to do the same thing, specifically if it can provide us with two pvids (e.g. if walking the vlan list) or if it can provide us with a pvid different from the one set in the vg. [Obviously, I'm talking about RCU pvid/vlan use cases similar to the dumps. The locked cases are fine. I would like to avoid explaining why this shouldn't be relied upon without locking] So instead of introducing the above change and making sure of the pvid uniqueness under RCU, simply dynamically populate the pvid flag in br_vlan_get_info(). Signed-off-by: Vladimir Oltean <olteanv@gmail.com> Acked-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'net/bridge')
-rw-r--r--net/bridge/br_vlan.c2
1 files changed, 2 insertions, 0 deletions
diff --git a/net/bridge/br_vlan.c b/net/bridge/br_vlan.c
index f5b2aeebbfe9..bb98984cd27d 100644
--- a/net/bridge/br_vlan.c
+++ b/net/bridge/br_vlan.c
@@ -1281,6 +1281,8 @@ int br_vlan_get_info(const struct net_device *dev, u16 vid,
p_vinfo->vid = vid;
p_vinfo->flags = v->flags;
+ if (vid == br_get_pvid(vg))
+ p_vinfo->flags |= BRIDGE_VLAN_INFO_PVID;
return 0;
}
EXPORT_SYMBOL_GPL(br_vlan_get_info);