diff options
author | Erik J. Staab <ejs@insightbb.com> | 2010-09-22 11:07:41 +0200 |
---|---|---|
committer | Takashi Iwai <tiwai@suse.de> | 2010-09-22 10:04:08 +0200 |
commit | 0873a5ae747847ee55a63db409dff3476e45bcd9 (patch) | |
tree | f2ce79f043f6249b3c702c82f1fe0a1d585a8ce0 /sound | |
parent | Linux 2.6.36-rc5 (diff) | |
download | linux-0873a5ae747847ee55a63db409dff3476e45bcd9.tar.xz linux-0873a5ae747847ee55a63db409dff3476e45bcd9.zip |
ALSA: oxygen: fix analog capture on Claro halo cards
On the HT-Omega Claro halo card, the ADC data must be captured from the
second I2S input. Using the default first input, which isn't connected
to anything, would result in silence.
Signed-off-by: Erik J. Staab <ejs@insightbb.com>
Signed-off-by: Clemens Ladisch <clemens@ladisch.de>
Cc: <stable@kernel.org>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
Diffstat (limited to 'sound')
-rw-r--r-- | sound/pci/oxygen/oxygen.c | 4 |
1 files changed, 4 insertions, 0 deletions
diff --git a/sound/pci/oxygen/oxygen.c b/sound/pci/oxygen/oxygen.c index 289cb4dacfc7..6c0a11adb2a8 100644 --- a/sound/pci/oxygen/oxygen.c +++ b/sound/pci/oxygen/oxygen.c @@ -543,6 +543,10 @@ static int __devinit get_oxygen_model(struct oxygen *chip, chip->model.suspend = claro_suspend; chip->model.resume = claro_resume; chip->model.set_adc_params = set_ak5385_params; + chip->model.device_config = PLAYBACK_0_TO_I2S | + PLAYBACK_1_TO_SPDIF | + CAPTURE_0_FROM_I2S_2 | + CAPTURE_1_FROM_SPDIF; break; } if (id->driver_data == MODEL_MERIDIAN || |