summaryrefslogtreecommitdiffstats
path: root/tools/iio
diff options
context:
space:
mode:
authorTomasz Duszynski <tduszyns@gmail.com>2018-12-14 19:28:01 +0100
committerJonathan Cameron <Jonathan.Cameron@huawei.com>2018-12-16 15:05:57 +0100
commit17abc9ec68b73ddeb262a507a62421016b9c54d5 (patch)
tree765effd1562e97ea39fd1f2ed330849a756f4aa8 /tools/iio
parentstaging: iio: ad7816: drop unnecessary initialization of variables (diff)
downloadlinux-17abc9ec68b73ddeb262a507a62421016b9c54d5.tar.xz
linux-17abc9ec68b73ddeb262a507a62421016b9c54d5.zip
iio: add IIO_MASSCONCENTRATION channel type
Measuring particulate matter in ug / m3 (micro-grams per cubic meter) is de facto standard. Existing air quality sensors usually follow this convention and are capable of returning measurements using this unit. IIO currently does not offer suitable channel type for this type of measurements hence this patch adds this. In addition, extra modifiers are introduced used for distinguishing between fine pm1, pm2p5 and coarse pm4, pm10 particle measurements, i.e IIO_MOD_PM1, IIO_MOD_PM25 and IIO_MOD_PM4, IIO_MOD_PM10. pmX consists of particles with aerodynamic diameter less or equal to X micrometers. Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com> Acked-by: Matt Ranostay <matt.ranostay@konsulko.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Diffstat (limited to 'tools/iio')
-rw-r--r--tools/iio/iio_event_monitor.c10
1 files changed, 10 insertions, 0 deletions
diff --git a/tools/iio/iio_event_monitor.c b/tools/iio/iio_event_monitor.c
index ac2de6b7e89f..f6b8003fbe3c 100644
--- a/tools/iio/iio_event_monitor.c
+++ b/tools/iio/iio_event_monitor.c
@@ -60,6 +60,7 @@ static const char * const iio_chan_type_name_spec[] = {
[IIO_GRAVITY] = "gravity",
[IIO_POSITIONRELATIVE] = "positionrelative",
[IIO_PHASE] = "phase",
+ [IIO_MASSCONCENTRATION] = "massconcentration",
};
static const char * const iio_ev_type_text[] = {
@@ -115,6 +116,10 @@ static const char * const iio_modifier_names[] = {
[IIO_MOD_Q] = "q",
[IIO_MOD_CO2] = "co2",
[IIO_MOD_VOC] = "voc",
+ [IIO_MOD_PM1] = "pm1",
+ [IIO_MOD_PM2P5] = "pm2p5",
+ [IIO_MOD_PM4] = "pm4",
+ [IIO_MOD_PM10] = "pm10",
};
static bool event_is_known(struct iio_event_data *event)
@@ -156,6 +161,7 @@ static bool event_is_known(struct iio_event_data *event)
case IIO_GRAVITY:
case IIO_POSITIONRELATIVE:
case IIO_PHASE:
+ case IIO_MASSCONCENTRATION:
break;
default:
return false;
@@ -200,6 +206,10 @@ static bool event_is_known(struct iio_event_data *event)
case IIO_MOD_Q:
case IIO_MOD_CO2:
case IIO_MOD_VOC:
+ case IIO_MOD_PM1:
+ case IIO_MOD_PM2P5:
+ case IIO_MOD_PM4:
+ case IIO_MOD_PM10:
break;
default:
return false;