summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
-rw-r--r--Documentation/devicetree/bindings/regulator/pwm-regulator.txt11
-rw-r--r--drivers/regulator/pwm-regulator.c9
2 files changed, 4 insertions, 16 deletions
diff --git a/Documentation/devicetree/bindings/regulator/pwm-regulator.txt b/Documentation/devicetree/bindings/regulator/pwm-regulator.txt
index 23b47720b2e4..ed936f0f34f2 100644
--- a/Documentation/devicetree/bindings/regulator/pwm-regulator.txt
+++ b/Documentation/devicetree/bindings/regulator/pwm-regulator.txt
@@ -29,15 +29,14 @@ Required properties:
- pwms: PWM specification (See: ../pwm/pwm.txt)
-One of these must be provided:
+Only required for Voltage Table Mode:
- voltage-table: Voltage and Duty-Cycle table consisting of 2 cells
First cell is voltage in microvolts (uV)
Second cell is duty-cycle in percent (%)
-- max-duty-cycle: Maximum Duty-Cycle value -- this will normally be
- 255 (0xff) for an 8 bit PWM device
-
-If both are provided, the current default is voltage-table mode.
+NB: To be clear, if voltage-table is provided, then the device will be used
+in Voltage Table Mode. If no voltage-table is provided, then the device will
+be used in Continuous Voltage Mode.
Any property defined as part of the core regulator binding can also be used.
(See: ../regulator/regulator.txt)
@@ -49,8 +48,6 @@ Continuous Voltage Example:
regulator-min-microvolt = <1016000>;
regulator-max-microvolt = <1114000>;
regulator-name = "vdd_logic";
-
- max-duty-cycle = <255>; /* 8bit PWM */
};
Voltage Table Example:
diff --git a/drivers/regulator/pwm-regulator.c b/drivers/regulator/pwm-regulator.c
index cb482089050b..d92e66772ec0 100644
--- a/drivers/regulator/pwm-regulator.c
+++ b/drivers/regulator/pwm-regulator.c
@@ -30,7 +30,6 @@ struct pwm_regulator_data {
int state;
/* Continuous voltage */
- u32 max_duty_cycle;
int volt_uV;
};
@@ -201,14 +200,6 @@ static int pwm_regulator_init_continuous(struct platform_device *pdev,
struct pwm_regulator_data *drvdata)
{
struct device_node *np = pdev->dev.of_node;
- int ret;
-
- ret = of_property_read_u32(np, "max-duty-cycle",
- &drvdata->max_duty_cycle);
- if (ret) {
- dev_err(&pdev->dev, "Failed to read \"pwm-max-value\"\n");
- return ret;
- }
pwm_regulator_desc.ops = &pwm_regulator_voltage_continuous_ops;
pwm_regulator_desc.continuous_voltage_range = true;