summaryrefslogtreecommitdiffstats
path: root/Documentation/ABI/testing/sysfs-bus-iio-temperature-max31856
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/ABI/testing/sysfs-bus-iio-temperature-max31856')
-rw-r--r--Documentation/ABI/testing/sysfs-bus-iio-temperature-max3185619
1 files changed, 13 insertions, 6 deletions
diff --git a/Documentation/ABI/testing/sysfs-bus-iio-temperature-max31856 b/Documentation/ABI/testing/sysfs-bus-iio-temperature-max31856
index 3b3509a3ef2f..e5ef6d8e5da1 100644
--- a/Documentation/ABI/testing/sysfs-bus-iio-temperature-max31856
+++ b/Documentation/ABI/testing/sysfs-bus-iio-temperature-max31856
@@ -5,9 +5,12 @@ Description:
Open-circuit fault. The detection of open-circuit faults,
such as those caused by broken thermocouple wires.
Reading returns either '1' or '0'.
- '1' = An open circuit such as broken thermocouple wires
- has been detected.
- '0' = No open circuit or broken thermocouple wires are detected
+
+ === =======================================================
+ '1' An open circuit such as broken thermocouple wires
+ has been detected.
+ '0' No open circuit or broken thermocouple wires are detected
+ === =======================================================
What: /sys/bus/iio/devices/iio:deviceX/fault_ovuv
KernelVersion: 5.1
@@ -18,7 +21,11 @@ Description:
cables by integrated MOSFETs at the T+ and T- inputs, and the
BIAS output. These MOSFETs turn off when the input voltage is
negative or greater than VDD.
+
Reading returns either '1' or '0'.
- '1' = The input voltage is negative or greater than VDD.
- '0' = The input voltage is positive and less than VDD (normal
- state).
+
+ === =======================================================
+ '1' The input voltage is negative or greater than VDD.
+ '0' The input voltage is positive and less than VDD (normal
+ state).
+ === =======================================================