summaryrefslogtreecommitdiffstats
path: root/Documentation/admin-guide
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/admin-guide')
-rw-r--r--Documentation/admin-guide/perf/hisi-pcie-pmu.rst32
-rw-r--r--Documentation/admin-guide/perf/index.rst1
-rw-r--r--Documentation/admin-guide/perf/starfive_starlink_pmu.rst46
3 files changed, 71 insertions, 8 deletions
diff --git a/Documentation/admin-guide/perf/hisi-pcie-pmu.rst b/Documentation/admin-guide/perf/hisi-pcie-pmu.rst
index 7e863662e2d4..5541ff40e06a 100644
--- a/Documentation/admin-guide/perf/hisi-pcie-pmu.rst
+++ b/Documentation/admin-guide/perf/hisi-pcie-pmu.rst
@@ -37,9 +37,21 @@ Example usage of perf::
hisi_pcie0_core0/rx_mwr_cnt/ [kernel PMU event]
------------------------------------------
- $# perf stat -e hisi_pcie0_core0/rx_mwr_latency/
- $# perf stat -e hisi_pcie0_core0/rx_mwr_cnt/
- $# perf stat -g -e hisi_pcie0_core0/rx_mwr_latency/ -e hisi_pcie0_core0/rx_mwr_cnt/
+ $# perf stat -e hisi_pcie0_core0/rx_mwr_latency,port=0xffff/
+ $# perf stat -e hisi_pcie0_core0/rx_mwr_cnt,port=0xffff/
+
+The related events usually used to calculate the bandwidth, latency or others.
+They need to start and end counting at the same time, therefore related events
+are best used in the same event group to get the expected value. There are two
+ways to know if they are related events:
+
+a) By event name, such as the latency events "xxx_latency, xxx_cnt" or
+ bandwidth events "xxx_flux, xxx_time".
+b) By event type, such as "event=0xXXXX, event=0x1XXXX".
+
+Example usage of perf group::
+
+ $# perf stat -e "{hisi_pcie0_core0/rx_mwr_latency,port=0xffff/,hisi_pcie0_core0/rx_mwr_cnt,port=0xffff/}"
The current driver does not support sampling. So "perf record" is unsupported.
Also attach to a task is unsupported for PCIe PMU.
@@ -51,8 +63,12 @@ Filter options
PMU could only monitor the performance of traffic downstream target Root
Ports or downstream target Endpoint. PCIe PMU driver support "port" and
- "bdf" interfaces for users, and these two interfaces aren't supported at the
- same time.
+ "bdf" interfaces for users.
+ Please notice that, one of these two interfaces must be set, and these two
+ interfaces aren't supported at the same time. If they are both set, only
+ "port" filter is valid.
+ If "port" filter not being set or is set explicitly to zero (default), the
+ "bdf" filter will be in effect, because "bdf=0" meaning 0000:000:00.0.
- port
@@ -95,7 +111,7 @@ Filter options
Example usage of perf::
- $# perf stat -e hisi_pcie0_core0/rx_mrd_flux,trig_len=0x4,trig_mode=1/ sleep 5
+ $# perf stat -e hisi_pcie0_core0/rx_mrd_flux,port=0xffff,trig_len=0x4,trig_mode=1/ sleep 5
3. Threshold filter
@@ -109,7 +125,7 @@ Filter options
Example usage of perf::
- $# perf stat -e hisi_pcie0_core0/rx_mrd_flux,thr_len=0x4,thr_mode=1/ sleep 5
+ $# perf stat -e hisi_pcie0_core0/rx_mrd_flux,port=0xffff,thr_len=0x4,thr_mode=1/ sleep 5
4. TLP Length filter
@@ -127,4 +143,4 @@ Filter options
Example usage of perf::
- $# perf stat -e hisi_pcie0_core0/rx_mrd_flux,len_mode=0x1/ sleep 5
+ $# perf stat -e hisi_pcie0_core0/rx_mrd_flux,port=0xffff,len_mode=0x1/ sleep 5
diff --git a/Documentation/admin-guide/perf/index.rst b/Documentation/admin-guide/perf/index.rst
index f4a4513c526f..7eb3dcd6f4da 100644
--- a/Documentation/admin-guide/perf/index.rst
+++ b/Documentation/admin-guide/perf/index.rst
@@ -13,6 +13,7 @@ Performance monitor support
imx-ddr
qcom_l2_pmu
qcom_l3_pmu
+ starfive_starlink_pmu
arm-ccn
arm-cmn
xgene-pmu
diff --git a/Documentation/admin-guide/perf/starfive_starlink_pmu.rst b/Documentation/admin-guide/perf/starfive_starlink_pmu.rst
new file mode 100644
index 000000000000..2932ddb4eb76
--- /dev/null
+++ b/Documentation/admin-guide/perf/starfive_starlink_pmu.rst
@@ -0,0 +1,46 @@
+================================================
+StarFive StarLink Performance Monitor Unit (PMU)
+================================================
+
+StarFive StarLink Performance Monitor Unit (PMU) exists within the
+StarLink Coherent Network on Chip (CNoC) that connects multiple CPU
+clusters with an L3 memory system.
+
+The uncore PMU supports overflow interrupt, up to 16 programmable 64bit
+event counters, and an independent 64bit cycle counter.
+The PMU can only be accessed via Memory Mapped I/O and are common to the
+cores connected to the same PMU.
+
+Driver exposes supported PMU events in sysfs "events" directory under::
+
+ /sys/bus/event_source/devices/starfive_starlink_pmu/events/
+
+Driver exposes cpu used to handle PMU events in sysfs "cpumask" directory
+under::
+
+ /sys/bus/event_source/devices/starfive_starlink_pmu/cpumask/
+
+Driver describes the format of config (event ID) in sysfs "format" directory
+under::
+
+ /sys/bus/event_source/devices/starfive_starlink_pmu/format/
+
+Example of perf usage::
+
+ $ perf list
+
+ starfive_starlink_pmu/cycles/ [Kernel PMU event]
+ starfive_starlink_pmu/read_hit/ [Kernel PMU event]
+ starfive_starlink_pmu/read_miss/ [Kernel PMU event]
+ starfive_starlink_pmu/read_request/ [Kernel PMU event]
+ starfive_starlink_pmu/release_request/ [Kernel PMU event]
+ starfive_starlink_pmu/write_hit/ [Kernel PMU event]
+ starfive_starlink_pmu/write_miss/ [Kernel PMU event]
+ starfive_starlink_pmu/write_request/ [Kernel PMU event]
+ starfive_starlink_pmu/writeback/ [Kernel PMU event]
+
+
+ $ perf stat -a -e /starfive_starlink_pmu/cycles/ sleep 1
+
+Sampling is not supported. As a result, "perf record" is not supported.
+Attaching to a task is not supported, only system-wide counting is supported.